Thermometer Type Thermometer Type |
---|
![]() | ![]() |
Direct Reading | Remote Reading |
Scale Scale |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
|
|
Housing Material Housing Material |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Probe Material Probe Material |
---|
|
Cable Material Cable Material |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Clip-On Freezer Thermometers
Monitor temperature in freezers, coolers, and storage areas with these thermometers.
The indicating color changes to red if the temperature gets too high for thermometers with a color changing temperature zone indicator, alerting you to make adjustments. Thermometers with a blinking temperature zone indicator will blink continuously to indicate that too high of a temperature has been reached.
Thermometers with a scale display are filled with mercury-free fluid for a quick response time. Thermometers with a dial or digital display make it easier to see small temperature fluctuations than those with a scale display.
NSF/ANSI 2 thermometers meet standards for food equipment. They show a blue indicating color when the temperature is in the safe zone for food.
Thermometers with a timer measure how long the temperature stays outside the safe zone, which helps you know if products are still viable after a power outage. Their min/max memory records the highest and lowest temperatures. When the temperature is in the safe zone for food, they show a green indicating color.

Fluid | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Graduation Marks | Resolution | Accuracy | Lg. | Ht. | Housing Material | Material | Color | Temperature Zone Indicator Type | Environment | Specifications Met | Includes | Each | |
-20° to 80° F/ -30° to 27° C | 2° F/1° C | 1° F/1° C | ±2° F/ ±1° C | 1 1/4" | 5 7/8" | Plastic | Glycol | Red | Color Changing | Food Industry | NSF/ANSI 2 | __ | 0000000 | 000000 |
-20° to 84° F/ -30° to 30° C | 2° F/2° C | 0.1° F/0.1° C | ±3° F/ ±1.5° C | 4 7/8" | 1 1/4" | Plastic | Diesel Fuel | Red | Color Changing | Food Industry | NSF/ANSI 2 | Two Suction Cups | 0000000 | 0000 |

Temperature Range | Graduation Marks | Accuracy | Ht. | Dial Dia. | Housing Material | Temperature Zone Indicator Type | Environment | Specifications Met | Each | |
-20° to 80° F/-30° to 30° C | 2° F/1° C | ±3° F/±1.5° C | 4" | 3" | Stainless Steel | Color Changing | Food Industry | NSF/ANSI 2 | 0000000 | 000000 |

Temperature Range | Resolution | Accuracy | Lg. | Ht. | Dial Dia. | Housing Material | Batteries Included | Temperature Zone Indicator Type | Features | Includes | Each | |
-4° to 140° F/-20° to 60° C | 0.1° F/0.1° C | ±2° F/±2° C | __ | 2 5/8" | 2 3/4" | Plastic | Yes | Color Changing | Min./Max. Memory, Timer | Magnet, Suction Cup | 0000000 | 000000 |
-4° to 140° F/-20° to 60° C | 0.1° F/0.1° C | ±4° F/±2° C | 2 3/4" | 2 3/8" | __ | Plastic | Yes | Blinking | Min./Max. Memory | Magnet | 0000000 | 00000 |
Food and Beverage Panel-Mount Thermometers




For use in food processing and preparation areas, these thermometers meet NSF/ANSI standards. They have an unthreaded probe attached to a cable for dropping into tanks, vats, and drums.
For technical drawings and 3-D models, click on a part number.
Available Temperature Ranges | ||
---|---|---|
Temperature Range | Graduation Marks | Accuracy |
-40° to 60° F/-40° to 15° C | 2° F/1° C | ±1% |
-40° to 110° F/-40° to 43° C | 2° F/1° C | ±1% |
40° to 240° F/0° to 115° C | 2° F/1° C | ±1% |
Probe | Mtg. Holes | Material | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Panel Cutout Dia. | Housing | Probe | Specifications Met | Each | |
*Only available in -40° to 110° F/-40° to 43° C | ||||||||||||||
Front Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 3/8" | 2 15/16" | 2 9/16" | 3 | 9/64" | No | 2 1/16" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 000000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 3 11/16" | 3 5/16" | 3 | 11/64" | No | 2 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 |
4 1/2" | 4 | 3 1/2" | 3/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 000000 |
Back Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 3/8" | 2 15/16" | 2 9/16" | 3 | 9/64" | No | 2 1/16" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 3 11/16" | 3 5/16" | 3 | 11/64" | No | 2 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 000000000 | 00000 |
4 1/2" | 4 | 3 1/2" | 3/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 000000 |
Remote-Reading Panel-Mount Thermometers






Monitor the temperature of difficult-to-access system components from a distance. The probe is connected to a cable, so the dial can be mounted away from your system. Mount the dial no more than 5 feet above or below the probe to ensure accuracy.
Bracket-mount thermometers have an adjustable bracket that allows the dial to pivot 90° front to back.
For technical drawings and 3-D models, click on a part number.
Available Temperature Ranges | ||
---|---|---|
Temperature Range | Graduation Marks | Accuracy |
40° to 240° F | 2° F | ±1% |
100° to 350° F | 2° F | ±1% |
-40° to 110° F/-40° to 43° C | 1° F/1° C | ±1% |
-20° to 100° F/-30° to 35° C | 2° F/1° C | ±1% |
0° to 150° F/-15° to 65° C | 2° F/1° C | ±1% |
0° to 180° F/-20° to 80° C | 1° F/1° C | ±1% |
30° to 300° F/0° to 150° C | 2° F/1° C | ±1% |
Probe | Mtg. Holes | Material | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Pipe Size | Thread Type | Gender | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | For Panel Cutout Dia. | Max. Pressure | Housing | Probe | Each | |
Front Flange Mount | |||||||||||||||||
3 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
3 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
3 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
3 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
Back Flange Mount | |||||||||||||||||
3 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 00000 |
3 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
3 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
3 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
4 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
Bracket Mount | |||||||||||||||||
3 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 00000 |
3 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
3 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
3 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
4 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
4 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
4 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
4 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
Optional Brass Thermowell | 000000 | Each | 000000 |
Remote-Reading Panel-Mount Freezer Thermometers with Audible Alarm

Protect temperature-sensitive materials in refrigerators and freezers with one of these thermometers that sound an alarm and flash the display when temperature rises above your activation point. Alarm requires a power supply (sold separately).
Probe | Mtg. Holes | For Panel Cutout | Input Voltage | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Actuation Point Temperature Range | Resolution | Accuracy | Cable Lg., ft. | Dia. | Lg. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | AC | DC | Electrical Connection | Frequency, Hz | Each | |
-25° F to 99° F/-32° C to 38° C | -15° F to 50° F/-26° C to 10° C | 1/1 | ±3° F | 6 | 3/8" | 7/8" | 2 | 7/32" | No | 3 7/8" | 2 7/8" | 5" | 3 1/8" | 10.5 to 28 | 12 to 28 | Wire Leads | 60 | 000000 | 0000000 |
12V AC Output/120V AC Input Power Supply | 0000000 | Each | 000000 |
Heavy Duty Panel-Mount Thermometers with Thermowell


The included thermowell protects the probe from the effects of vibration, shock, pressure, and corrosive liquids in tanks and pipelines. The probe is connected to a cable, so the dial can be mounted away from your system or in a control panel.
Available Temperature Ranges | ||
---|---|---|
Temperature Range | Graduation Marks | Accuracy |
0° to 300° F | 5° F | ±1% |
Probe | Mtg. Holes | Material | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Pipe Size | Thread Type | Gender | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Housing | Probe | Each | |
Back Flange Mount | |||||||||||||||
4 1/2" | 20 | 2 1/2" | 5/8" | 3/4 | NPT | Male | 5 13/16" | 5 3/8" | 3 | 7/32" | No | Aluminum | Stainless Steel | 00000000 | 0000000 |