Number of Terminals Number of Terminals |
---|
|
Industry Designation Industry Designation | Show |
---|
|
Industry Designation Industry Designation | Hide |
---|
|
Switch Starting Position Switch Starting Position |
---|
|
Number of Circuits Controlled Number ofCircuits Controlled |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | Screw Terminals |
Relay Type Relay Type |
---|
![]() | Standard |
Application Application |
---|
|
Circuit Position Circuit Position |
---|
|
Operation Type Operation Type |
---|
|
Switch Action Switch Action |
---|
|
Mechanical Life Cycles Mechanical Life Cycles |
---|
|
Specifications Met Specifications Met |
---|
|
More
Recessed screw terminals prevent accidental contact with live connections. These relays are built to International Electrotechnical Commission (IEC) dimensional standards.
Auxiliary contact (sold separately) allows you to add a signaling device or control another relay.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 600V AC | Ht. | Wd. | Dp. | For DIN Rail Size, mm | Specifications Met | Each | |
4 Circuits Controlled with 2 Off (Normally Open) and 2 On (Normally Closed)—4PST-2NO/2NC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
10 | 24V DC | 13 | 10A | 2.3" | 1.7" | 2.2" | 35 | UL Listed, C-UL Listed | 0000000 | 000000 |
Number of Circuits Controlled | Switch Starting Position | Industry Designation | Mounting Location | Each | |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-NO/NC | Front | 00000000 | 000000 |
The interlocked opposing contacts won't close at the same time, so these relays are suitable for safety applications such as machine guarding. The screw terminals are recessed to prevent accidental contact with live connections. Relays are built to International Electrotechnical Commission (IEC) dimensional standards.
Auxiliary contact (sold separately) allows you to add a signaling device or control another relay.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 600V AC | Ht. | Wd. | Dp. | For DIN Rail Size, mm | Specifications Met | Each | |
4 Circuits Controlled with 2 Off (Normally Open) and 2 On (Normally Closed)—4PST-2NO/2NC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
10 | 24V AC | 125 | 10A | 2.3" | 1.7" | 2.2" | 35 | UL Listed, C-UL Listed | 00000000 | 000000 |
10 | 120V AC | 25 | 10A | 2.3" | 1.7" | 2.2" | 35 | UL Listed, C-UL Listed | 00000000 | 00000 |
10 | 240V AC | 12.5 | 10A | 2.3" | 1.7" | 2.2" | 35 | UL Listed, C-UL Listed | 00000000 | 00000 |
Number of Circuits Controlled | Switch Starting Position | Industry Designation | Mounting Location | Each | |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-NO/NC | Front | 00000000 | 000000 |
The built-in enclosure protects contacts from dust and dirt. These relays accept voltage drops up to 50% of the rated voltage without switching. Use them with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Switching Current @ Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | hp @ Switching Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | |
4 Circuits Controlled with 2 Off (Normally Open) and 2 On (Normally Closed)—4PST-2NO/2NC | |||||||||||
With Screw Terminals | |||||||||||
10 | 120V AC | 22 | 25 A @ 220 V AC/24 V DC | 8 A @ 220 V AC/24 V DC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | UL Recognized CSA Certified CE Marked | 0000000 | 000000 |
10 | 24V DC | 83 | 25 A @ 220 V AC/24 V DC | 8 A @ 220 V AC/24 V DC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | UL Recognized CSA Certified CE Marked | 0000000 | 00000 |