Input Voltage Input Voltage | Show |
---|
|
Input Voltage Input Voltage | Hide |
---|
Mounting Location Mounting Location |
---|
|
Switch Starting Position Switch Starting Position |
---|
|
Operation Type Operation Type |
---|
|
Socket Connection Type Socket Connection Type |
---|
![]() | ![]() |
Quick- Disconnect Terminals | Circular Pin Terminals |
Switch Action Switch Action |
---|
|
Control Current Control Current |
---|
|
|
|
Width Width |
---|
|
|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Circuit Position Circuit Position |
---|
|
Mechanical Life Cycles Mechanical Life Cycles |
---|
|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Relays
More
About Timer Relays
More
Compact Spade-Terminal Relays





Smaller than standard spade-terminal relays in height and depth, these relays save space inside your control cabinet. Attach quick-disconnect terminals or plug relays into relay sockets.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current | Relay Sockets | ||||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | @ 120V AC | @28V DC | Max. Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Features | Specifications Met | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||||
8 | 12V DC | 75 | 15A | 12A | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 000000 | 0000000 | 00000 |
8 | 12V DC | 92 | 10A | 10A | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 000000000 | 00000 | 0000000 | 0000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||||
11 | 12V DC | 117 | 15A | 12A | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 00000 | 0000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open) or 4 On (Normally Closed)—4PDT | |||||||||||||||
14 | 12V DC | 92 | 8A | 8A | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 000000000 | 00000 | 0000000 | 0000 |
14 | 12V DC | 125 | 15A | 12A | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 00000 | 0000000 | 00000 |
Thin Spade-Terminal Relays


Thinner than other spade-terminal relays, these fit in tight spaces. Attach quick-disconnect terminals or plug relays into relay sockets. Use them for low-current switching applications such as small motors and pilot lights.
Relay sockets with screw terminals (sold separately) mount to 35 mm DIN rail or flat surfaces.
Relay sockets with spring-clamp terminals (sold separately) mount to 35 mm DIN rail.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets with Screw Terminals | Relay Sockets with Spring-Clamp Terminals | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Switching Current @ 120V AC/28V DC | Control Current, mA | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
5 | 12V DC | 10A | 43 | 1/3 hp @ 120 V AC | 1.1" | 0.5" | 1.4" | 0.187" | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||||
8 | 12V DC | 5A | 43 | 1/6 hp @ 120 V AC | 1.1" | 0.5" | 1.4" | 0.098" | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Spade-Terminal Relays




Attach quick-disconnect terminals or plug these relays into relay sockets. Also known as ice cube relays.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 000000 | 0000000 | 000000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||
11 | 12V DC | 100 | 15A | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
Long-Life Spade-Terminal Relays

With no moving parts, these solid state relays have an extended service life. Use them for high-speed switching at low current levels.
Heat sink can be used to disperse heat to increase the relay’s current rating. Mount to 35 mm DIN rail or flat surfaces.
Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ 120V AC/240V AC | Quick-Disconnect Tab Wd. | Heat Sinks | |||||||||||
Number of Terminals | Input Voltage | Without Heat Sink | With Heat Sink | Ht. | Wd. | Dp. | Control Terminal | Load Terminal | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||
4 | 12V DC | 5A | __ | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | UL Recognized Component C-UL Recognized Component CSA Certified CE Marked | 00000000 | 000000 | 000000 | 00 |
4 | 12V DC | 5A | 10A | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | UL Recognized Component C-UL Recognized Component CSA Certified CE Marked | 00000000 | 00000 | 0000000 | 000000 |
Circular-Pin Relays



8-Terminal
Relay

The circular pin terminals plug into relay sockets for easy installation. Also known as ice cube relays.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
Relays | Relay Sockets | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||
8 | 12V DC | 112 | 10A | 1.4" | 1.4" | 2.1" | UL Recognized Component, CSA Certified | 0000000 | 000000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||
11 | 12V DC | 112 | 10A | 1.4" | 1.4" | 2.1" | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
Premium Circular-Pin Relays



8-Terminal
Relay

Built to handle tough, repetitive-use applications, these are more durable than standard relays. The circular pin terminals plug into relay sockets for easy installation. Also known as ice cube relays.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
Relays | Relay Sockets | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC/28V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
8 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 000000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
PC-Board Pin Relays


Solder these relays to a printed circuit board. Use them to switch small motors and pilot lights.
For technical drawings and 3-D models, click on a part number.
Mechanical Life Cycles | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 250V AC/30V DC | Max. Switching Voltage | For AC Voltage | For DC Voltage | Ht. | Wd. | Dp. | Pin Lg. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 12V DC | 44 | 10A | 380V AC/125V DC | 10,000,000 | 20,000,000 | 1.1" | 0.5" | 1" | 0.16" | UL Recognized Component CSA Certified CE Marked | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 12V DC | 44 | 5A | 380V AC/125V DC | 10,000,000 | 20,000,000 | 1.1" | 0.5" | 1" | 0.16" | UL Recognized Component CSA Certified CE Marked | 0000000 | 0000 |
Enclosed Medium-Current Relays

The built-in enclosure protects contacts from dust and dirt. These relays accept voltage drops up to 50% of the rated voltage without switching. Use them with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Switching Current @ Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Off (Normally Open) Circuit Position | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||
With Quick-Disconnect Terminals | |||||||||||
6 | 12V DC | 158 | 25 A @ 220 V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |
Medium-Current Relays


Use these relays with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Optional covers protect contacts from dust and dirt.
Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current | Optional Covers | ||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | @ 120V AC | @ 28V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||
4 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 000000 | 0000000 | 000000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||||
6 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
High-Starting-Current Vehicle Relays


Relay Socket and
Surface Mounting



Also known as automotive relays, these relays can handle high starting (inrush) currents.
Relays for surface mounting have a tab for added security in high-vibration applications.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | |||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
For Relay Socket | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 150 | 138 | 1.02" | 1.02" | 0.94" | 0.25" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 000000 |
For Relay Socket and Surface Mounting | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
4 | 12V DC | 50 A @ 12 V DC | __ | 150 | 138 | 1.2" | 1" | 1" | 0.25" and 0.375" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 00000 |
5 | 12V DC | 40 A @ 12 V DC | __ | 150 | 141 | 1" | 1" | 0.9" | 0.25" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 150 | 138 | 1.1" | 1.1" | 1" | 0.25" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 00000 |
Weatherproof High-Starting-Current Vehicle Relays


Crimp-On
Terminals

The extended housing covers and protects terminals. Also known as automotive relays, they can handle high starting (inrush) currents. They have a tab for added security in high-vibration applications.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | |||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 150 | 138 | 1.4" | 1.4" | 1.8" | 0.25" | 0000000 | 00000 | 0000000 | 000000 | 0000000 | 000000 |
Long-Life High-Starting-Current Vehicle Relays



With no moving parts, these solid state relays have an extended service life. They can handle high starting (inrush) currents. Also known as automotive relays.
Relays | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Switching Current @ 12V DC | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||||
4 | 12V DC | 20A | 80 | 10 | 1.1" | 1.1" | 1" | 0.25" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
Water-Resistant High-Current Vehicle Relays


These relays are suitable for DC-powered equipment such as forklifts, floor scrubbers, and trucks. Rated for continuous operation for cycles that run longer than 30 seconds.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Power, VA | Full Load Switching Current @ Voltage | Ht. | Wd. | Dp. | Wire Connection Type | Stud Thread Size | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
4 | 12V DC | 8 | 200 A @ 12 V DC | 3.7" | 3.3" | 2.9" | Stud Terminals | 5/16"-24 | 0000000 | 000000 |
4 | 12V DC | 8.1 | 100 A @ 12 V DC | 2.9" | 3.3" | 2.1" | Stud Terminals | 5/16"-24 | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||
6 | 12V DC | 12 | 100 A @ 12 V DC | 4.6" | 3.3" | 2.9" | Stud Terminals | 5/16"-24 | 0000000 | 00000 |
High-Current Vehicle Relays


These relays are suitable for DC-powered equipment such as forklifts, floor scrubbers, and trucks. They are rated for continuous operation for cycles that run longer than 30 seconds.
3-terminal relays require the same input and switching voltage. 4- and 6-terminal relays allow different input and switching voltages.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Power, VA | Full Load Switching Current @ Voltage | Ht. | Wd. | Dp. | Wire Connection Type | Stud Thread Size | Features | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3 | 12V DC | 12 | 100 A @ 12 V DC | 3.6" | 3.1" | 2.2" | Stud Terminals | 5/16"-24 | __ | 0000000 | 000000 |
4 | 12V DC | 9 | 80 A @ 12 V DC | 2.5" | 3.5" | 2.4" | Stud Terminals | 5/16"-24 | __ | 0000000 | 00000 |
4 | 12V DC | 9 | 80 A @ 12 V DC | 2.5" | 3.5" | 2.4" | Stud Terminals | 5/16"-24 | Grounding Cord with Ring Terminal | 0000000 | 00000 |
4 | 12V DC | 12 | 100 A @ 12 V DC | 3.6" | 3.1" | 2.2" | Stud Terminals | 5/16"-24 | __ | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||
6 | 12V DC | 12 | 100 A @ 12 V DC | 4.7" | 3.1" | 2.2" | Stud Terminals | 5/16"-24 | __ | 0000000 | 00000 |
Sequenced Latching Relays

These relays switch through a series of different circuit configurations every time they receive an input voltage. The input voltage latches them in position, so they don’t require a constant voltage to stay switched. Use them to control motors, pumps, and lighting. The covered terminals prevent contact with live connections. Mount to 35 mm DIN rail. Also known as step relays.
For technical drawings and 3-D models, click on a part number.
Switch Starting Position | Input Voltage | Control Power | Switching Current @ 24V AC/120V AC | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | |
1 Circuit Controlled—SPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
With 4 Terminals | ||||||||||
1st Signal—1 Off (Normally Open) 2nd Signal—1 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 000000 |
2 Circuits Controlled—DPST-1NO/1NC | ||||||||||
With 6 Terminals | ||||||||||
1st Signal—1 Off (Normally Open) and 1 On (Normally Closed) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
2 Circuits Controlled—DPST-NO | ||||||||||
With 6 Terminals | ||||||||||
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
Latching Relays




A single, momentary input voltage switches these relays and latches them in position, so they don't require a constant input voltage to stay switched. A second momentary voltage will release the latch.
Relay sockets (sold separately) mount to 35 mm DIN rail.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC/28V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
9 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 000000 | 0000000 | 000000 |
10 | 12V DC | 110 | 5A | __ | 1.1" | 0.8" | 1.4" | 0.102" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
Ultra-Thin Signal Relays with Socket

Plug these relays into the included socket for fast installation; they disconnect for easy replacement. Relays are extra narrow to maximize space inside your control cabinet. Use them with circuits that control electrical signals. Mount to 35 mm DIN rail.
Relays | Replacement Relays | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 250V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Features | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 12V AC/12V DC | 16 | 6A | 400V AC | 3.5" | 0.2" | 3" | Power Indicator | UL Recognized Component, C-UL Recognized Component | 0000000 | 000000 | 0000000 | 00000 |
Socket-Mount Multifunction Timer Relays


Plug relays into relay sockets for fast installation and replacement. They provide a variety of timing functions in one relay.
Relay socket (sold separately) mounts to 35 mm DIN rail or flat surfaces.
Relays | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Relay Sockets | |||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ 240V AC | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
11 | 12V DC | 167 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 5 | 0.05 sec.-999 min. | 10A | 2.4" | 1.8" | 3.7" | UL Recognized Component | 0000000 | 0000000 | 0000000 | 00000 |
Socket-Mount Timer Relays


8-Terminal
Relay
Plug relays into relay sockets for fast installation and replacement. Use them in applications where machinery needs to turn on or off after a set period of time, such as in paint and conveyor lines.
Relay socket (sold separately) mounts to 35 mm DIN rail or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Timer Relays | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Switching Current | Relay Sockets | |||||||||
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | @ 240V AC | @ 28V DC | Specifications Met | Each | Each | ||
Delayed Start (Delay-on-Make) | |||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||
8 | 12V DC | 170 | 1 | 0.1 sec.-10 sec. | 10A | 8A | UL Recognized Component CSA Certified CE Marked | 0000000 | 000000 | 0000000 | 00000 |
8 | 12V DC | 170 | 1 | 0.6 sec.-60 sec. | 10A | 8A | UL Recognized Component CSA Certified CE Marked | 0000000 | 00000 | 0000000 | 0000 |
Repeat Cycle | |||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||
8 | 12V DC | 170 | 1 | 1.8 sec.-180 sec. | 10A | 8A | UL Recognized Component CSA Certified CE Marked | 0000000 | 00000 | 0000000 | 0000 |
Wide-Range Socket-Mount Timer Relays



Postpone starts longer and set wider intervals than with most timer relays. These relays plug into relay sockets for fast installation and replacement.
Relay socket (sold separately) mounts to 35 mm DIN rail or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Timer Relays | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Relay Sockets | |||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ Voltage | hp @ Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
Delayed Start (Delay-on-Make) | ||||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
8 | 12V DC | 271 | 5 | 0.05 sec.-999 min. | 10 A @ 240 V AC | __ | 2.4" | 1.75" | 2.9" | UL Recognized Component | 000000 | 0000000 | 0000000 | 00000 |
Delayed Switch-Off (Delay-on-Break) | ||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10 A @ 240 V AC/28 V DC | 0.33 hp @ 240 V AC | 2.38" | 1.75" | 2.9" | UL Recognized Component | 00000000 | 00000 | 0000000 | 0000 |
Interval | ||||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10 A @ 240 V AC/28 V DC | 0.33 hp @ 240 V AC | 2.4" | 1.7" | 2.9" | UL Recognized Component | 00000000 | 000000 | 0000000 | 0000 |
Repeat Cycle | ||||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10 A @ 240 V AC/28 V DC | 0.33 hp @ 240 V AC | 2.4" | 1.7" | 2.9" | UL Recognized Component | 00000000 | 000000 | 0000000 | 0000 |
Switch-On (Single-Shot) | ||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10 A @ 240 V AC/28 V DC | 0.33 hp @ 240 V AC | 2.4" | 1.7" | 2.9" | UL Recognized Component | 00000000 | 00000 | 0000000 | 0000 |
Long-Life Surface-Mount Timer Relays

With no moving parts, these solid state relays have an extended service life. Use the mounting hole to attach to a flat surface. A potentiometer (variable switch) adjusts the delay within the range.
For technical drawings and 3-D models, click on a part number.
Timer Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Potentiometers | ||||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ 120V AC | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Features | Specifications Met | Each | Each | ||
Delayed Start (Delay-on-Make) | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
2 | 12V AC/12V DC | 21 | 1 | 0.05 sec.-1 sec. | 1A | 2" | 2" | 0.89" | 0.25" | Potentiometer | UL Recognized Component | 000000000 | 000000 | 000000 | 00 |
2 | 12V AC/12V DC | 21 | 1 | 0.25 sec.-5 sec. | 1A | 2" | 2" | 0.89" | 0.25" | Potentiometer | UL Recognized Component | 000000000 | 00000 | 000000 | 00 |
2 | 12V AC/12V DC | 21 | 1 | 0.5 sec.-10 sec. | 1A | 2" | 2" | 0.89" | 0.25" | Potentiometer | UL Recognized Component | 000000000 | 00000 | 000000 | 00 |
2 | 12V AC/12V DC | 21 | 1 | 3 sec.-60 sec. | 1A | 2" | 2" | 0.89" | 0.25" | Potentiometer | UL Recognized Component | 000000000 | 00000 | 000000 | 00 |
2 | 12V AC/12V DC | 21 | 1 | 15 sec.-300 sec. | 1A | 2" | 2" | 0.89" | 0.25" | Potentiometer | UL Recognized Component | 000000000 | 00000 | 000000 | 00 |
2 | 12V AC/12V DC | 21 | 1 | 30 sec.-10 min. | 1A | 2" | 2" | 0.89" | 0.25" | Potentiometer | UL Recognized Component | 000000000 | 00000 | 000000 | 00 |
Delayed Switch-Off (Delay-on-Break) | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
7 | 12V DC | 217 | 1 | 0.25 sec.-5 sec. | 1A | 2" | 2" | 0.88" | 0.25" | __ | UL Recognized Component | 00000000 | 00000 | 00000000 | 000000 |
7 | 12V DC | 217 | 1 | 0.5 sec.-10 sec. | 1A | 2" | 2" | 0.88" | 0.25" | __ | UL Recognized Component | 00000000 | 00000 | 00000000 | 00000 |
7 | 12V DC | 217 | 1 | 3 sec.-60 sec. | 1A | 2" | 2" | 0.88" | 0.25" | __ | UL Recognized Component | 00000000 | 00000 | 00000000 | 00000 |
Switch-On (Single-Shot) | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
7 | 12V DC | 217 | 1 | 0.25 sec.-5 sec. | 1A | 2" | 2" | 0.88" | 0.25" | __ | UL Recognized Component | 00000000 | 00000 | 00000000 | 00000 |
7 | 12V DC | 217 | 1 | 0.5 sec.-10 sec. | 1A | 2" | 2" | 0.88" | 0.25" | __ | UL Recognized Component | 00000000 | 00000 | 00000000 | 00000 |
7 | 12V DC | 217 | 1 | 3 sec.-60 sec. | 1A | 2" | 2" | 0.88" | 0.25" | __ | UL Recognized Component | 00000000 | 00000 | 00000000 | 00000 |
Surface-Mount Timer Relays

Use the mounting hole to attach these relays to a flat surface. A potentiometer (variable switch) adjusts the delay within the range.
For technical drawings and 3-D models, click on a part number.
Timing Range | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Number of | Overall | Switching Current @ 250V AC | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | |
Delayed Start (Delay-on-Make) | ||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 12V DC | 292 | 1 | 3 sec.-60 sec. | 8A | 2" | 2" | 0.9" | 0.25" | UL Recognized Component | 000000000 | 000000 |
5 | 12V DC | 292 | 1 | 15 sec.-300 sec. | 8A | 2" | 2" | 0.9" | 0.25" | UL Recognized Component | 000000000 | 00000 |
Compact Programmable Logic Controllers
Smaller than other PLCs, these controllers save space in your control cabinet. They combine the functionality of a relay, timer relay, and switch in one unit, so you can program simple automation jobs. All have two types of delayed start (delay-on-make) and two types of delayed switch-off (delay-on-break) timing functions. They have passed strict U.S. and Canadian safety standards, and they’re IP20, which prevents fingers and other objects from making contact with live circuits. Mount them to a 35-mm DIN rail.
Controllers with a display make it easy to monitor or modify your system directly on the unit. Controllers without a display eliminate the risk of accidental adjustments while toggling through information or tampering by unauthorized users.
Program these controllers by connecting them to a computer and installing the required software (sold separately). After the initial programming, these controllers can be updated remotely by a human-machine interface (HMI) or computer.
Add expansion modules to increase the number of inputs and outputs. You can connect up to 11 modules to a controller—for a maximum of 188 inputs and outputs. Choose any modules that support the operating voltage of your controller.
For technical drawings and 3-D models, click on a part number.


Digital Inputs | Digital Outputs | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Input Signal Type | Voltage | No. of | Voltage | Current | No. of | Signal Type | Operating Voltage | Communication Protocol | Software Included | Each | |
Controllers with Display | |||||||||||
Eaton Easy E4 Series | |||||||||||
Digital, Analog | 12V DC 24V AC 24V DC 0-10V DC | 8 (4 can be analog) | 240V AC | 8A | 4 | Relay | 12V DC 24V AC 24V DC | Modbus TCP/IP | No | 000000 | 0000000 |
Controllers without Display | |||||||||||
Eaton Easy E4 Series | |||||||||||
Digital, Analog | 12V DC 24V AC 24V DC 0-10V DC | 8 (4 can be analog) | 240V AC | 8A | 4 | Relay | 12V DC 24V AC 24V DC | Modbus TCP/IP | No | 0000000 | 000000 |
Manufacturer Model Number | For Operating System | Media Type | Each | |
For Eaton Easy E4 Series | ||||
---|---|---|---|---|
EASYSOFT-SWLIC/EasySoft 7 | Windows 7, Windows 8, Windows 8.1, Windows 10 | Download | 000000 | 000000 |