Switching Current Switching Current | Show |
---|
|
Switching Current Switching Current | Hide |
---|
Operation Type Operation Type |
---|
|
Switching Current with Heat Sink Switching Currentwith Heat Sink |
---|
|
Switch Starting Position Switch Starting Position |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | Screw Terminals |
Application Application |
---|
|
Specifications Met Specifications Met |
---|
|
Auxiliary Contact Switch Starting Position Auxiliary ContactSwitch Starting Position |
---|
|
Relay Type Relay Type |
---|
![]() | Standard |
Switch Action Switch Action |
---|
|
More
With no moving parts, these solid state relays have an extended service life.
Heat sinks can be used to disperse heat to increase the relay’s current rating. Mount to 35 mm DIN rail or flat surfaces. Before mounting one-circuit relays, silicone compound should be applied between the heat sink and relay.
Relays | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current | Heat Sinks | |||||||||||
Number of Terminals | Input Voltage | Without Heat Sink | With Heat Sink | Switching Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||
With High-Starting-Current Protection | ||||||||||||
4 | 85-280V AC | 11A | 45A | 240V AC | 2.3" | 1.8" | 1.1" | UL Recognized CSA Certified CE Marked | 0000000 | 000000 | 0000000 | 0000000 |
4 | 3-32V DC | 11A | 45A | 120V AC | 2.3" | 1.8" | 1.1" | UL Recognized CSA Certified CE Marked | 0000000 | 00000 | 0000000 | 000000 |
4 | 3-32V DC | 11A | 45A | 240V AC | 2.3" | 1.8" | 1.1" | UL Recognized CSA Certified CE Marked | 0000000 | 00000 | 0000000 | 000000 |
Silicone Compound for One-Circuit Relays (8 oz.) | 00000000 | Each | 000000 |
Use these relays with large motors and lighting systems. Also known as IEC contactors, they are built to International Electrotechnical Commission (IEC) dimensional standards. All have recessed terminals to prevent contact with live connections. Mount to 35 mm DIN rail.
Auxiliary contacts allow you to add a signaling device or control another relay. Add one front-mount contact per relay or two side-mount contacts per relay.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Specifications Met | Each | |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
With 1 Auxiliary Contact—1 Off (Normally Open) | ||||||||||||
12 | 24V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 000000 |
12 | 120V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 24V DC | 5.4W | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed | 00000000 | 00000 |
With 1 Auxiliary Contact—1 On (Normally Closed) | ||||||||||||
12 | 24V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 24V DC | 5.4W | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed | 00000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |