Input Voltage Input Voltage |
---|
|
|
Switching Current Switching Current | Show |
---|
|
Switching Current Switching Current | Hide |
---|
Mounting Location Mounting Location |
---|
|
Switch Starting Position Switch Starting Position |
---|
|
Operation Type Operation Type |
---|
|
Power Power |
---|
Application Application |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Screw Terminals | Quick- Disconnect Terminals |
Mechanical Life Cycles Mechanical Life Cycles |
---|
|
|
Switch Action Switch Action |
---|
|
Specifications Met Specifications Met |
---|
|
More
The built-in enclosure protects contacts from dust and dirt. These relays accept voltage drops up to 50% of the rated voltage without switching. Use them with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Switching Current @ Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Off (Normally Open) Circuit Position | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||
With Quick-Disconnect Terminals | |||||||||||
4 | 24V AC | 71 | 30 A @ 220 V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | UL Recognized CSA Certified CE Marked | 0000000 | 000000 |
4 | 120V AC | 20 | 30 A @ 220 V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | UL Recognized CSA Certified CE Marked | 0000000 | 00000 |
4 | 240V AC | 10 | 30 A @ 220 V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | UL Recognized CSA Certified CE Marked | 0000000 | 00000 |
Use these relays with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Optional covers protect contacts from dust and dirt.
Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current | Optional Covers | ||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | @ 120V AC | @ 28V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||
4 | 24V AC | 396 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 000000 | 0000000 | 000000 |
4 | 120V AC | 79 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
4 | 240V AC | 40 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
4 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
4 | 24V DC | 83 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 24V AC | 396 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
5 | 120V AC | 79 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
5 | 240V AC | 40 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
5 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
5 | 24V DC | 83 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||||
6 | 24V AC | 396 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
6 | 120V AC | 79 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
6 | 240V AC | 40 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
6 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
6 | 24V DC | 83 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC | 396 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 79 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 40 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
8 | 12V DC | 167 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 83 | 30A | 30A | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | UL Listed C-UL Listed | 0000000 | 00000 | 0000000 | 00000 |
Mount these relays directly to 35 mm DIN rail. They are solid state, so they have no moving parts and have an extended service life. Relays have an attached heat sink that disperses heat to provide optimal convection cooling.
Number of Terminals | Input Voltage | Switching Current @ Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||
---|---|---|---|---|---|---|---|---|
With High-Starting-Current Protection | ||||||||
2 | 3-32V DC | 30 A @ 230 V AC | 4.2" | 0.9" | 5.4" | UL Listed C-UL Listed | 0000000 | 000000 |
2 | 20-275V AC/24-190V DC | 30 A @ 230 V AC | 4.2" | 0.9" | 5.4" | UL Listed C-UL Listed | 0000000 | 00000 |
With no moving parts, these solid state relays have an extended service life. Mount them directly to 35 mm DIN rail. They have an integrated heat sink that disperses heat to provide optimal convection cooling. An LED indicator tells you if they are open or closed. Relays are rated for continuous operating duty. They do not switch DC loads.
Number of Terminals | Input Voltage | Control Current, mA | Full Load Switching Current @ 600V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Single Phase | ||||||||||
4 | 4-32V DC | 13 | 30A | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 4.2" | 0.9" | 5.4" | UL Listed C-UL Listed CE Marked | 0000000 | 000000 |
4 | 20-275V AC/24-190V DC | 22 | 30A | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 4.2" | 0.9" | 5.4" | UL Listed C-UL Listed CE Marked | 0000000 | 00000 |
For use with equipment that cycles on and off, these relays meet UL 508 for air conditioning and heating. Connections are accessible from the front, so you can mount relays side-by-side. Also known as definite-purpose contactors.
Enclosures (sold separately) are NEMA 1 rated to protect contacts from corrosion.
Also Available: Auxiliary contacts for 3.8"-7.2" Ht. relays. They allow you to add a signaling device or control another relay. Please select 6564K99, then select the McMaster-Carr part number of your relay and whether you want to switch one circuit on (1 Normally Open) or off (1 Normally Closed).
Switching Current @ 600V AC | hp @ Switching Voltage | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||
With Quick-Disconnect and Screw Terminals | |||||||||||||
2 | 24V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 000000 |
2 | 24V AC | 6VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
2 | 120V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
2 | 120V AC | 6VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
2 | 208/240V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
2 | 208/240V AC | 6VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||||
With Quick-Disconnect and Screw Terminals | |||||||||||||
4 | 24V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
4 | 24V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
4 | 24V DC | 3.1W | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.8" | 2.4" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 000000 |
4 | 208/240V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
4 | 208/240V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||||
With Quick-Disconnect and Screw Terminals | |||||||||||||
6 | 24V AC | 7VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
6 | 120V AC | 7VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
6 | 24V DC | 3.1W | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 000000 |
6 | 208/240V AC | 7VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | |||||||||||||
With Quick-Disconnect and Screw Terminals | |||||||||||||
8 | 24V AC | 50.4VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 000000 |
8 | 120V AC | 50.4VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 000000 |
8 | 24V DC | 5.1W | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 000000 |
8 | 208/240V AC | 50.4VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | UL Recognized Component, CSA Certified, CE Marked, UL 508 | 00000000 | 000000 |
Enclosures for 60A 3PST-NO Relays and 4PST-NO Relays | 00000000 | Each | 0000000 |
Mount these relays directly to 35 mm DIN rail. For use with equipment that cycles on and off, they meet UL 508 for air conditioning and heating. All have recessed terminals to prevent contact with live connections. Also known as definite-purpose contactors.
Auxiliary contacts allow you to add a signaling device or control another relay.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Specifications Met | Each | |
Relays | ||||||||||||
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 000000 |
12 | 24V AC | 6.5VA | 25A | 30A | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 24V AC | 6.5VA | 30A | 32A | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 25A | 30A | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 30A | 32A | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 230V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 230V AC | 6.5VA | 25A | 30A | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 230V AC | 6.5VA | 30A | 32A | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 24V DC | 5.4W | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed UL 508 | 0000000 | 00000 |
Relays with 1 Off (Normally Open) Auxiliary Contact | ||||||||||||
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 24V AC | 6.5VA | 25A | 30A | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 24V AC | 6.5VA | 30A | 32A | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 25A | 30A | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 30A | 32A | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 230V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed UL 508 | 00000000 | 00000 |
12 | 24V DC | 5.4W | 20A | 30A | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed UL 508 | 0000000 | 00000 |
12 | 24V DC | 5.4W | 25A | 30A | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed UL 508 | 0000000 | 00000 |
12 | 24V DC | 5.4W | 30A | 32A | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed UL 508 | 0000000 | 000000 |
Also known as automotive relays, these relays can handle high starting (inrush) currents.
Relays for surface mounting have a tab for added security in high-vibration applications.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | |||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
For Relay Socket | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 150 | 138 | 1.02" | 1.02" | 0.94" | 0.25" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 000000 |
For Relay Socket and Surface Mounting | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 150 | 138 | 1.1" | 1.1" | 1" | 0.25" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 00000 |
The extended housing covers and protects terminals. Also known as automotive relays, they can handle high starting (inrush) currents. They have a tab for added security in high-vibration applications.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | |||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 150 | 138 | 1.4" | 1.4" | 1.8" | 0.25" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
Also known as power relays, these are suitable for compressors, blowers, and heaters.
Timing Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ 120V AC/28V DC | hp @ Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | |
Delayed Start (Delay-on-Make) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 000000 |
5 | 120V AC | 36 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
Delayed Switch-Off (Delay-on-Break) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
Interval | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
Repeat Cycle | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
Switch-On (Single-Shot) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 sec.-100 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 10 sec.-1,000 sec. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30A | 1 hp @ 120 V AC | 3" | 2" | 1.4" | 0.25" | UL Recognized CSA Certified | 00000000 | 00000 |