Probe Length Probe Length |
---|
|
|
|
Connection Type Connection Type |
---|
![]() | ![]() |
Wire Leads | Screw Terminal |
![]() | ![]() |
DIN Connection | Plug |
RTD Type RTD Type |
---|
|
Probe Material Probe Material |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Head Material Head Material |
---|
|
Overall Length Overall Length |
---|
|
|
|
Material Material |
---|
|
Maximum Voltage Maximum Voltage |
---|
|
|
About Selecting Temperature Sensors
More
Threaded RTD Probe Transmitters for Liquids and Gases
Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in transmitter, these RTDs don’t require a separate signal converter. They’re threaded, so they’re ready to install into containers, tanks, and pipes. These RTDs are made of 316 or 316L stainless steel, so they’re highly corrosion resistant. All are CE Marked as meeting European safety standards.
RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. They’re also UL listed and C-UL listed for American and Canadian safety standards.
For technical drawings and 3-D models, click on a part number.

Probe | Probe Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Lg. | Dia. | Accuracy | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Choose a Temperature Range | Each | |
316 Stainless Steel Probe with Plastic Head (IP65) | |||||||||||||
100 ohms | 2 1/2" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 5 3/4" | 000000 | 0000000 | |
100 ohms | 4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 7 1/4" | 000000 | 000000 | |
100 ohms | 6" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 9 1/4" | 000000 | 000000 | |
100 ohms | 9" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 12 1/4" | 000000 | 000000 | |
100 ohms | 12" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 15 1/4" | 0000000 | 000000 |

Probe | Probe Connection | Probe Transmitters | Cables with Socket | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Communication Protocol | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe (IP67, IP68, IP69K) | |||||||||||||||||
1,000 ohms | 0° to 300° | 1 3/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 5,800 | 4-20mA | IO Link | 4 1/8" | 0000000 | 0000000 | 0000000 | 000000 |
1,000 ohms | 0° to 300° | 2" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 5" | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 0° to 300° | 3 15/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 7" | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 0° to 300° | 5 15/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 8 7/8" | 0000000 | 000000 | 0000000 | 00000 |
Cut-to-Length RTD Probes for Liquids and Gases


Use a pipe cutter to trim these probes for an exact fit.
Probes with six wires are dual probes. Use them to control two output devices or to get an average temperature reading across two different areas.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 400° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 72" | 1/4" | 68 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 96" | 1/4" | 92 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 900° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
RTD Probes with Armored Cable for Liquids and Gases


For long service life in harsh conditions, these RTD probes have an armored stainless steel cable to protect wiring from corrosion, abrasion, and impact.
Probes with strain relief offer extra support for moving cables. They also help avoid kinking for longer cable life.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range , ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Cable Material | Max. Cable Temperature, ° F | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
Probe | ||||||||||||||
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 3.5 | 6 | Wire Leads | Stainless Steel Armor | 400° | 6ft. | 24 | 3 | 0000000 | 0000000 |
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 10 | 3 | Wire Leads | Stainless Steel Armor | 400° | 36" | 24 | 3 | 0000000 | 000000 |
100 ohms | -55° to 400° | 12" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 000000 |
Probe with Strain Relief | ||||||||||||||
100 ohms | -55° to 400° | 3" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 00000 |
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 00000 |
100 ohms | -55° to 400° | 12" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 00000 |
Threaded RTD Probe Transmitters with Digital Display for Liquids and Gases
View temperature readings and adjust settings directly on these RTD probe transmitters. To communicate with programmable logic controllers (PLCs), they have a built-in transmitter with two outputs. One output can send a digital switching signal or use IO Link protocol with the addition of an IO Link controller (not included). The other can send a digital switching signal or a 4-20mA analog signal. The different output options make these RTDs good for a wide range of uses, including operating far away from a controller, taking automated measurements, and providing inputs to switching applications. All probes are threaded, so they’re ready to install into containers, tanks, and pipes. Made of 316L stainless steel, they are highly corrosion resistant.
These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. UL Listed, C-UL Listed, and CE Marked, all meet American, Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.

Probe | Configurable Digital Output | Configurable Analog/Digital Output | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Plug Type | Probe Connection Pipe Size | Max. Pressure, psi | No. of | Communication Protocol | Signal Type | No. of | Current | Signal Type | Overall Lg. | Each | |
NPT Male Probe Connection | |||||||||||||||||
316L Stainless Steel Probe with Plastic Head (IP67) | |||||||||||||||||
1,000 ohms | -55° to 300° | 1" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/4 | 5,800 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 4 7/8" | 0000000 | 0000000 |
1,000 ohms | -55° to 300° | 1 3/16" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 4,350 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 4 7/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 2" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/4 | 5,800 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 5 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 2" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 4,350 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 5 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 3 15/16" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 3,625 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 7 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 5 15/16" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 3,625 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 9 1/2" | 0000000 | 000000 |
Cable Lead Lg., ft. | Voltage | Current | Face Diameter | Each | |
12 | 250V AC/250V DC | 4A | 0.3" | 0000000 | 000000 |
Threaded RTD Probes with Thermowell for Liquids and Gases

To protect the probe from vibration, corrosion, and shock, these RTD probes come with a thermowell.
Probe | Thermowell Connection | Conduit Connection | Material | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Overall Lg. | Head | Probe | Each | |
304 Stainless Steel Thermowell | |||||||||||||||||
100 ohms | -55° to 400° | 5 1/2" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 14 1/8" | Cast Iron | 304 Stainless Steel | 0000000 | 0000000 |
100 ohms | -55° to 400° | 8 1/2" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 17 1/8" | Cast Iron | 304 Stainless Steel | 0000000 | 000000 |
100 ohms | -55° to 400° | 11 1/2" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 20 1/8" | Cast Iron | 304 Stainless Steel | 0000000 | 000000 |
Threaded RTD Probe Transmitters for Air



A built-in transmitter converts the probe’s air-temperature readings to a 4-20 mA signal for use with switches, controllers, and data loggers. Consider the temperature of your application when selecting a probe. Choose a temperature range that closely matches your application to save time configuring the probe. For more flexibility, choose a probe with a large range. You can reconfigure probes for multiple applications.
Replacement elements include a ¼” probe, spring, and 3” of leads.
For technical drawings and 3-D models, click on a part number.
Probes | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Probe Connection | Conduit Connection | Replacement Elements | ||||||||||||||||
RTD Type | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Head Material | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | DC Voltage | Overall Lg. | Choose a Temperature Range | Each | Each | ||
316 Stainless Steel Probe | |||||||||||||||||||
100 ohms | 4" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 9" | 0000000 | 0000000 | 00000000 | 000000 | |
100 ohms | 6" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 11" | 0000000 | 000000 | 00000000 | 00000 | |
100 ohms | 9" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 14" | 0000000 | 000000 | 00000000 | 00000 | |
100 ohms | 12" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 17" | 0000000 | 000000 | 00000000 | 00000 |
Replacement Transmitter for Probes with 0° to 100° F Temperature Range | 00000000 | Each | 0000000 |
Replacement Transmitter for Probes with 0° to 200° F Temperature Range | 00000000 | Each | 000000 |
Replacement Transmitter for Probes with 0° to 400° F Temperature Range | 00000000 | Each | 000000 |
Replacement Transmitter for Probes with 0° to 300° F Temperature Range | 00000000 | Each | 000000 |
RTD Probes for Air

Use these RTD probes for more stable air-temperature readings than thermocouple probes.
Probe | Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Max. Cable Temperature, ° F | Lead Lg. | Gauge | Each | |
Platinum Probe | ||||||||||||
PTFE Cable | ||||||||||||
100 ohms | -55° to 400° | 5/8" | 1/8" | ±0.12% | 5 | 3 | Wire Leads | 400° | 1/2" | 24 | 0000000 | 000000 |
100 ohms | -55° to 400° | 5/8" | 1/8" | ±0.12% | 5 | 6 | Wire Leads | 400° | 1/2" | 24 | 0000000 | 00000 |
Fiberglass Cable | ||||||||||||
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 3 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 6 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 10 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 25 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
Sanitary RTD Probes
Designed for clean-in-place applications such as dairy processing and food-preparation areas, these 3-A certified RTDs have a sanitary quick-clamp connection for easy removal.
For technical drawings and 3-D models, click on a part number.

Probe | Conduit Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Overall Lg. | Each | |
316 Stainless Steel Probe with Plastic Head | |||||||||||||
For 1 1/2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 1.984" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 0000000 |
For 2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 2.516" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 000000 |
Sanitary RTD Probe Transmitters with Digital Display
Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're rated IP67 and IP69K, so they'll withstand temporary submersion as well as the high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. Made of stainless steel, harsh cleaners and sanitizers won't cause them to corrode. They have a flange that will connect to sanitary quick-clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
Program these probes with the touch screen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet DIN EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
For technical drawings and 3-D models, click on a part number.


Probe | Probe Transmitters | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Plug Type | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe with 304 Stainless Steel Head (IP67, IP69K) | |||||||||||||||
For 1 1/2" Tube OD | |||||||||||||||
100 ohms | -55° to 480° | 2" | 5/16" | 1.988" | ±0.1% | 25 | 5-Pole Micro M12 | 8-35 | 580 | 4-20mA | 6 3/4" | 0000000 | 0000000 | 0000000 | 000000 |
Terminal Blocks for RTD Wire

Connect RTD wire leads to conduit or instrumentation.
For Max. Wire Gauge | Wire Connection Type | Each | |
14 | Screw Terminals | 00000000 | 000000 |
Thermocouple and RTD Connection Heads


A removable cap seals out dust and moisture and provides easy access to sensor connections.
Hazardous location connection heads are rated for use in Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 environments with flammable gases, combustible dust, and combustible fibers.
Probe Connection | Conduit Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Includes | Environment | Environmental Rating | Each | |
Aluminum | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 000000 |
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | Hazardous Location | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 4X | 00000000 | 00000 |
Cast Iron | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 00000 |
Plastic | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Hinged Cap | __ | __ | 00000000 | 00000 |
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 00000 |
Stainless Steel | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 000000 |
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | Hazardous Location | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 | 00000000 | 000000 |
Thermocouple and RTD Fittings

Adapt unthreaded thermocouple and RTD connections for use with threaded tanks and connection heads.
For Probe OD | Pipe Size | O-Ring Material | Material | Each | |
1/4" | 1/2 NPT Male × 1/2 NPT Male | Fluoroelastomer | Stainless Steel | 00000000 | 000000 |