McMaster-Carr logo
    Filter by
    Power Source
    System of Measurement
    Maximum Flow Rate
    Discharge Pipe Size
    Industrial Info Compare
    Intake Pipe Size
    Industrial Info Compare
    Container Size
    Flow Rate @ 10 Feet of Head
    For Drum Opening Pipe Size
    Industrial Info Compare
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    47 Products

    Extended-Life Plastic Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Plastic Circulation Pumps for Chemicals.
    These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Repair Kits
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    Max. ft. of
    Head, ft.
    Power,
    hp
    Current
    Intake Pipe Size
    (Gender)
    Discharge Pipe
    Size (Gender)
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    232010351/42.07 amp/4.14 amp1 (Female)1 (Female)14 3/8"5 1/8"7 7/8"3068N110000000003068N11200000003068N111000000
    262612351/33.24 amp/6.84 amp1 (Female)1 (Female)16 5/16"6 1/8"8 3/16"3068N12000000003068N1220000003068N12100000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    5757533025451/21.1 amp/2.2 amp1 1/2 (Female)1 1/2 (Female)18 3/8"8 7/8"11 5/16"3068N13000000003068N1320000003068N13100000
    9090847461497011.5 amp/3 amp1 1/2 (Female)1 1/2 (Female)18 7/8"6 5/16"10 1/8"3068N14000000003068N1420000003068N14100000
     

    Fixed-Flow-Rate Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Fixed-Flow-Rate Peristaltic Pumps for Chemicals.
    Also known as tubing pumps, these maintain a fixed flow rate. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount them up to 25 feet above your liquid source. All can run dry. Do not use with solids.
    Polypropylene and Tygon Wetted Parts—Pumps with Tygon 2375 lining resist harsh substances such as isopropyl alcohol and sodium chloride.
    Pumps
    Replacement
    Pump Heads
    Overall
    Flow Rate, gal./day
    (For Tube ID)
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp.,
    ° F
    Power
    Current,
    amp
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    115V AC, Single Phase—Plug In
     
    Polypropylene and Tygon Wetted Parts
    0.07 (1/16")
    0.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K227000000043045K116000000
    0.34 (1/16")
    1.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K22800000043045K11600000
    0.87 (1/16")
    3.53 (1/8")
    6.84 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23200000043045K12200000
    1.75 (1/16")
    7.07 (1/8")
    13.68 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23300000043045K12200000
    22.8 (3/16")
    38 (1/4")
    1550032 to 122Fractional0.525"5"7"6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23700000043045K12700000
    45.6 (3/16")
    76 (1/4")
    1520032 to 122Fractional0.655"5"7"6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23800000043045K12700000
    228 (3/16")
    380 (1/4")
    155032 to 122Fractional1.745"5"7"6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60)43045K23900000043045K12700000
     
    Replacement Pump Intake Tubes

    Adjustable-Flow Easy-Stroke Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Easy-Stroke Drum Pumps for Water and Chemicals, 304 Stainless Steel Housing.

    304 Stainless

    Steel Housing

    These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
    Whenever working with flammable liquids, always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.
    Intake
    Flow Rate, fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    For Discharge
    Tube ID
    Spout
    Type
    Each
    304 Stainless Steel Intake Tube and 304 Stainless Steel Housing
    6, 8, 10, 1215 to 552,000Not Rated1401 1/2 NPT, 2 NPTDrum Connector1 1/8"18 1/2" to 32 1/2"11/16"Removable2515K460000000
     

    Compact Air-Powered Double Diaphragm Pumps

    Small enough to fit in the palm of your hand, these pumps transfer water, detergents, and chemicals. They have a chemical-resistant polypropylene housing. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps can run dry.
    Barbed Bottom Intake and Barbed Bottom Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Compact Air-Powered Double Diaphragm Pumps, Barbed Bottom Intake and Barbed Bottom Discharge.
    Fluoroelastomer Diaphragm—Pumps with fluoroelastomer diaphragm are also suitable for use with fuel and oil.
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 1 ft.
    of Head
    @ 3 ft.
    of Head
    @ 4 ft.
    of Head
    @ 5 ft.
    of Head
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Tube
    Connection
    Intake Tube
    Connection
    Discharge Tube
    Connection
    Diaphragm
    Material
    Lg.
    Wd.
    Ht.
    Each
    15 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    553.72.91.87001.51/4" Barbed Male3/8" Male3/8" MaleSantoprene
    4 9/16"1 13/16"5 13/16"2753N130000000
    553.72.91.87001.751/4" Barbed Male1/2" Male1/2" MaleSantoprene
    4 9/16"1 13/16"5 13/16"2753N11000000
    553.72.91.87001.751/4" Barbed Male1/2" Male1/2" MaleFluoroelastomer
    4 9/16"1 13/16"5 13/16"2753N12000000
     

    PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals

    With all PTFE wetted parts, these pumps offer the best chemical resistance of all our air-powered double diaphragm pumps and can handle solvents and petroleum-based fluids that PVDF pumps can’t. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All can run dry.
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals, Threaded Side Intake and Threaded Side Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Overall
    Max. Flow
    Rate, gpm
    Max. Solids
    Dia.
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    6.70.08"9.31/8 Female NPT3/8 Female NPT3/8 Female NPT3 1/2"5 7/8"7 5/8"2925N20000000002666N2900000002666N220000000
    160.16"291/4 Female NPT1/2 Female NPT1/2 Female NPT6"9 3/16"8"2925N3000000002666N310000002666N2300000000
    390.24"461/4 Female NPT1 Female NPT1 Female NPT8"10 7/8"10 3/8"2925N4000000002666N320000002666N2400000000
     

    Remote-Adjustment High-Pressure Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Remote-Adjustment High-Pressure Peristaltic Pumps for Chemicals.
    Automatically control output from a distance using a variety of analog and digital signals, including 4-20mA and external pulse signals. Pumps can also be controlled manually, run on a schedule, or set to cycle on and off. View flow rate on the LED display. These pumps handle pressures four times higher than standard pumps. They meter a consistent amount of liquid within ±1% of the maximum flow. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake
    Connection
    Discharge
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    120V AC, Single Phase with With Thermal Overload Protection
     
    Plug In
    0.05 to 51001,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N201000000000
    0.17 to 171001,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N20200000000
    0.4 to 401001,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N20300000000
    0.85 to 85251,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N20400000000
    1.3 to 1251001,50032 to 100Not Rated0.6Compression
    Compression
    11"8 3/4"8 1/8"20 ft. of 3/8" OD Tubing2886N20500000000
     
    back to top