About Actuated On/Off Valves
More
About Hazardous Location Environmental Ratings
More
Solenoid On/Off Valves

These solenoid valves operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Normally closed valves are closed unless actuated. Normally open valves are open unless actuated.
Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation. Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
All IP- or NEMA-rated valves stand up to dust and washdowns. NEMA 4X valves withstand corrosive liquid.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
- For Use With: Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton
- Specifications Met: See table
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Each | |
Bronze Body with Wire Leads—Buna-N Rubber Seal | |||||||||
---|---|---|---|---|---|---|---|---|---|
NPT Female | |||||||||
1/4 | 2.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 0000000 |
3/8 | 2.3 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 000000 |
1/2 | 3.9 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 000000 |
3/4 | 5.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 1/4" | 5 1/4" | NEMA 4X | 00000000 | 000000 |
1 | 11.6 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 13/16" | 5 11/16" | NEMA 4X | 00000000 | 000000 |
1 1/4 | 12.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 4 1/4" | 6 5/16" | NEMA 4X | 00000000 | 000000 |
1 1/2 | 26 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 4 7/8" | 6 15/16" | NEMA 4X | 00000000 | 000000 |
2 | 48 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 5 7/8" | 7 9/16" | NEMA 4X | 00000000 | 00000000 |
- For Use With: Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton
- Specifications Met: See table
Valves | Replacement Solenoid Coils | Repair Kits for Flow-Control Valves | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | Each | Each | |||
Bronze Body with Wire Leads—Buna-N Rubber Seal | ||||||||||||
NPT Female | ||||||||||||
1/2 | 3.5 | 300 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 3 1/4" | 7 1/8" | 0000000 | 0000000 | 0000000 | 000000 | 0000000 | 0000000 |
3/4 | 7.5 | 160 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 3 7/16" | 7 3/8" | 00000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1 | 13 | 160 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 4 1/8" | 7 7/8" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1 1/4 | 17 | 90 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 4 7/16" | 8 3/8" | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
1 1/2 | 25 | 115 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 4 7/8" | 10" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
2 | 48 | 100 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 6" | 11 1/8" | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
- For Use With: Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton
- Specifications Met: UL Listed
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Each | |
Bronze Body with Wire Leads—Buna-N Rubber Seal | |||||||||
---|---|---|---|---|---|---|---|---|---|
NPT Female | |||||||||
1/4 | 2.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 0000000 |
3/8 | 2.3 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 000000 |
1/2 | 3.9 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 000000 |
3/4 | 5.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 1/4" | 5 1/4" | NEMA 4X | 00000000 | 000000 |
1 | 11.6 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 13/16" | 5 11/16" | NEMA 4X | 00000000 | 000000 |
1 1/4 | 12.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 4 1/4" | 6 5/16" | NEMA 4X | 00000000 | 000000 |
1 1/2 | 26 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 4 7/8" | 6 15/16" | NEMA 4X | 00000000 | 000000 |
2 | 48 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 5 7/8" | 7 9/16" | NEMA 4X | 00000000 | 00000000 |
- For Use With:
Brass Body:
Buna-N Rubber Seal: Water, Air, Argon, Helium, Neon, Xenon, Krypton
Fluoroelastomer Rubber Seal: Water
Bronze Body: Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton - Specifications Met: See table
Valves | Replacement Solenoid Coils | Repair Kits for Flow-Control Valves | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | Each | Each | |||
Bronze Body with Wire Leads—Buna-N Rubber Seal | ||||||||||||
NPT Female | ||||||||||||
1/2 | 3.5 | 300 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 3 1/4" | 8 3/16" | 0000000 | 0000000 | 0000000 | 000000 | 0000000 | 0000000 |
1 | 13 | 110 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 4 1/16" | 9 1/4" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
1 1/2 | 25 | 115 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 4 13/16" | 11 7/16" | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
2 | 48 | 100 psi @ 210° F | Zero Pressure Drop | -40° to 210° | 6" | 12 1/2" | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
Hazardous Location Solenoid On/Off Valves

- For Use With: See table
- Seal Material:
Bronze Body: Buna-N Rubber
303 Stainless Steel Body: PCTFE Plastic - Specifications Met:
Bronze Body: UL Listed
303 Stainless Steel Body: UL Listed, CSA Certified
These valves are rated for use in hazardous locations with flammable gas and combustible dust. They operate on electricity to automatically start and stop flow. Valves are normally closed unless actuated. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Use With | Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Each | |
Bronze Body with Wire Leads | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Normally Closed—120V AC | ||||||||||||
Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton | 1/2 | Female | NPT | 3.9 | 150 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 7 1/4" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 NEMA 7 | 0000000 | 0000000 |
Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton | 3/4 | Female | NPT | 5.1 | 150 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 1/4" | 7 1/4" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 NEMA 7 | 0000000 | 000000 |
Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton | 1 | Female | NPT | 11.6 | 150 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 13/16" | 7 5/8" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 NEMA 7 | 0000000 | 000000 |
Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton | 2 | Female | NPT | 48 | 150 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 5 7/8" | 9 1/2" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 NEMA 7 | 0000000 | 00000000 |
Solenoid On/Off Valves for Cryogenic Liquids
Built to withstand the extreme cold of liquid nitrogen and liquid oxygen, these valves are cleaned and bagged for high-purity applications. They operate on electricity to automatically start and stop flow.
All valves are normally closed unless actuated. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.

- For Use With: Liquid Argon, Liquid Nitrogen, Liquid Oxygen
- Seal Material: Glass-Filled PTFE Plastic
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Normally Closed—24V AC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/2 | Female | NPT | 3.5 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7" | 0000000 | 0000000 |
3/4 | Female | NPT | 7.5 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/2" | 7 1/8" | 0000000 | 000000 |
1 | Female | NPT | 13 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 4 1/8" | 8" | 0000000 | 000000 |
Normally Closed—24V DC | ||||||||||
1/2 | Female | NPT | 3.5 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7" | 0000000 | 000000 |
1 | Female | NPT | 13 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 4 1/8" | 8" | 0000000 | 000000 |
Normally Closed—120V AC | ||||||||||
1/2 | Female | NPT | 3.5 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7 1/16" | 0000000 | 000000 |
1/2 | Female | NPT | 3.5 | 200 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7 1/16" | 0000000 | 000000 |
3/4 | Female | NPT | 7.5 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/2" | 7 3/8" | 0000000 | 000000 |
1 | Female | NPT | 13 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 4 1/8" | 8 1/8" | 0000000 | 000000 |
Solenoid On/Off Valves for Steam
These valves are designed to withstand the high temperatures and pressures in steam service applications. They operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Normally closed valves are closed unless actuated.
Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation. Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.

- For Use With: Steam
Valves | Repair Kits | Replacement Solenoid Coils | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Steam Pressure | Pressure Drop | Temp. Range for Water, °F | Valve Lg. | O'all Ht. | Each | Each | Each | |||
Normally Closed—120V AC | ||||||||||||||
1/2 | Female | NPT | 4 | 140 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7" | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 |
1/2 | Female | NPT | 4 | 180 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 8" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1/2 | Female | NPT | 4 | 90 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
3/4 | Female | NPT | 8 | 110 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 3 1/2" | 7 3/8" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
3/4 | Female | NPT | 8 | 180 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 3 1/2" | 8 1/4" | 0000000 | 000000 | 000000 | 000000 | 0000000 | 000000 |
3/4 | Female | NPT | 8 | 50 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 3 1/2" | 7 3/8" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1 | Female | NPT | 13 | 180 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 4 1/8" | 9" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1 | Female | NPT | 13 | 50 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 4 1/8" | 8" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1 | Female | NPT | 13 | 90 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 4 1/8" | 8" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1 1/4 | Female | NPT | 17 | 140 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 4 7/16" | 9 7/16" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
1 1/2 | Female | NPT | 25 | 180 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 4 7/8" | 11" | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
1 1/2 | Female | NPT | 25 | 90 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 4 7/8" | 10" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
2 | Female | NPT | 48 | 115 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 6" | 12 1/16" | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
2 | Female | NPT | 48 | 180 psi @ 400° F | Zero Pressure Drop | -350° to 400° | 6" | 12 1/16" | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |

- For Use With: Water, Steam
- Specifications Met: See table
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Steam Pressure | Pressure Drop | Temp. Range for Water, °F | Valve Lg. | O'all Ht. | Environmental Rating | Specifications Met | Each | |
Normally Closed—120V AC | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/4 | Female | NPT | 2 | 125 psi @ 355° F | Pressure Drop Assisted | -40° to 355° | 2 3/4" | 4 15/16" | NEMA 4X | UL Listed | 0000000 | 0000000 |
3/8 | Female | NPT | 2 | 125 psi @ 355° F | Pressure Drop Assisted | -40° to 355° | 2 3/4" | 4 15/16" | NEMA 4X | UL Listed | 0000000 | 000000 |
1/2 | Female | NPT | 4 | 125 psi @ 355° F | Pressure Drop Assisted | -40° to 355° | 2 3/4" | 4 15/16" | NEMA 4X | UL Listed | 0000000 | 000000 |
3/4 | Female | NPT | 5 | 125 psi @ 355° F | Pressure Drop Assisted | -40° to 355° | 3 1/4" | 5 5/16" | NEMA 4X | UL Listed | 0000000 | 000000 |
1 | Female | NPT | 12 | 125 psi @ 355° F | Pressure Drop Assisted | -40° to 355° | 3 13/16" | 5 11/16" | NEMA 4X | UL Listed | 0000000 | 000000 |
1 1/4 | Female | NPT | 12 | 125 psi @ 355° F | Pressure Drop Assisted | -40° to 355° | 4 1/4" | 6 5/16" | NEMA 4X | UL Listed | 0000000 | 000000 |
1 1/2 | Female | NPT | 26 | 125 psi @ 355° F | Pressure Drop Assisted | -40° to 355° | 4 7/8" | 6 15/16" | NEMA 4X | UL Listed | 0000000 | 000000 |
2 | Female | NPT | 48 | 150 psi @ 365° F | Pressure Drop Assisted | -40° to 365° | 5 7/8" | 8 15/16" | NEMA 1 | UL Listed | 00000000 | 00000000 |