For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
Actuation Actuation |
---|
![]() | Electric (Solenoid) |
Valve Type Valve Type |
---|
|
Duty Cycle Duty Cycle |
---|
|
Mounting Orientation Mounting Orientation |
---|
|
Pressure Drop Pressure Drop |
---|
|
Flow Pattern Flow Pattern |
---|
![]() |
L-Pattern |
Valve Starting Position Valve Starting Position |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Wire Connection Type Wire Connection Type |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Vacuum Rating (Text) Vacuum Rating (Text) |
---|
|
More
For applications sensitive to contamination, these valves stop flow without contacting the process media by pressing down on the outside of tubing. They operate on electricity to automatically start and stop flow.
These valves are normally closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet IP65 for resistance to low-pressure jets of water and dust.
For technical drawings and 3-D models, click on a part number.
For Tube | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
OD | ID | Max. Tube Durometer | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Dia. | O'all Ht. | No. of Mounting Slots | Mounting Slot Lg. | Fasteners Included | Each | |
Anodized Aluminum Body with DIN Connection | ||||||||||||
Normally Closed—12V DC | ||||||||||||
1/8" | 1/16" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 5/8" | 2 1/8" | 2 | 1/8" | No | 00000000 | 0000000 |
3/16" | 1/8" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1" | 3 3/8" | 2 | 1/8" | No | 00000000 | 000000 |
3/8" | 1/4" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1 3/16" | 4" | 2 | 1/8" | No | 00000000 | 000000 |
Normally Closed—24V DC | ||||||||||||
1/8" | 1/16" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 5/8" | 2 1/8" | 2 | 1/8" | No | 00000000 | 000000 |
3/16" | 1/8" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1" | 3 3/8" | 2 | 1/8" | No | 00000000 | 000000 |
3/8" | 1/4" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1 3/16" | 4" | 2 | 1/8" | No | 00000000 | 000000 |
Supply fuel oil to boilers, furnaces, and other heating equipment. These valves operate on electricity to automatically start and stop flow.
All are normally closed unless actuated. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Zero pressure drop valve does not require a minimum pressure drop between the inlet and outlet for operation. Pressure drop assisted valve requires a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Brass Body with Wire Leads | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Normally Closed—120V AC | ||||||||||
1/4 | Female | NPT | 0.8 | 300 psi @ 70° F | Pressure Drop Assisted | -10° to 180° | 2" | 3 1/2" | 00000000 | 0000000 |
3/8 | Female | NPT | 4.4 | 230 psi @ 70° F | Zero Pressure Drop | -10° to 180° | 2 15/16" | 3 11/16" | 00000000 | 000000 |
Often used for chemical analysis and other laboratory testing, these valves have a PTFE seal and body to withstand aggressive and corrosive solutions. All operate on electricity to automatically divert flow between ports. They do not require a pressure drop for operation. Any port can be used as an inlet or an outlet. Valves can direct flow from the inlet port to either outlet port. They cannot shut off flow. The actuator is mounted directly to the valve body to minimize movement and reduce wear.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Size | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Min. Pressure Drop Required | Temp. Range, °F | Actuation Time | Valve Lg. | O'all Ht. | Mounting Fasteners Included | No. of | Thread Size | Each | |
PTFE Plastic Body with Wire Leads—12V DC | |||||||||||||||
NPS Female × NPS Female × NPS Female | |||||||||||||||
1/8 | __ | L-Pattern | 15.85 | 30 psi @ 70° F | Zero Pressure Drop | None | 35° to 155° | 0.04 sec. | 1 3/4" | 2" | No | 7 | 4-40 | 0000000 | 0000000 |
UNF Female × UNF Female × UNF Female | |||||||||||||||
__ | 1/4"-28 | L-Pattern | 10.57 | 30 psi @ 70° F | Zero Pressure Drop | None | 35° to 155° | 0.02 sec. | 1 1/2" | 1 13/16" | No | 7 | 4-40 | 0000000 | 000000 |
__ | 10-32 | L-Pattern | 2.64 | 30 psi @ 70° F | Zero Pressure Drop | None | 35° to 155° | 0.02 sec. | 3/4" | 1 3/16" | No | 5 | 2-56 | 0000000 | 00000 |
PTFE Plastic Body with Wire Leads—24V DC | |||||||||||||||
NPS Female × NPS Female × NPS Female | |||||||||||||||
1/8 | __ | L-Pattern | 15.85 | 30 psi @ 70° F | Zero Pressure Drop | None | 35° to 155° | 0.04 sec. | 1 3/4" | 2" | No | 7 | 4-40 | 0000000 | 000000 |
UNF Female × UNF Female × UNF Female | |||||||||||||||
__ | 1/4"-28 | L-Pattern | 10.57 | 30 psi @ 70° F | Zero Pressure Drop | None | 35° to 155° | 0.02 sec. | 1 1/2" | 1 13/16" | No | 7 | 4-40 | 0000000 | 000000 |
__ | 10-32 | L-Pattern | 2.64 | 30 psi @ 70° F | Zero Pressure Drop | None | 35° to 155° | 0.02 sec. | 3/4" | 1 3/16" | No | 5 | 2-56 | 0000000 | 00000 |