For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
Body Material Body Material |
---|
|
Actuation Actuation |
---|
|
Valve Starting Position Valve Starting Position |
---|
|
Valve Function Valve Function |
---|
|
Valve Type Valve Type |
---|
|
Mounting Orientation Mounting Orientation |
---|
|
Shape Shape |
---|
![]() | Straight |
Duty Cycle Duty Cycle |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Pressure Drop Pressure Drop |
---|
|
Wire Connection Type Wire Connection Type |
---|
|
Actuator Housing Material Actuator Housing Material |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
![]() | Hardwire |
Maximum Current Draw Maximum Current Draw |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Vacuum Rating (Text) Vacuum Rating (Text) |
---|
|
More
For applications sensitive to contamination, these valves stop flow without contacting the process media by pressing down on the outside of tubing. They operate on electricity to automatically start and stop flow.
These valves are normally closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet IP65 for resistance to low-pressure jets of water and dust.
For technical drawings and 3-D models, click on a part number.
For Tube | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
OD | ID | Max. Tube Durometer | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Dia. | O'all Ht. | No. of Mounting Slots | Mounting Slot Lg. | Fasteners Included | Each | |
Anodized Aluminum Body with DIN Connection | ||||||||||||
Normally Closed—12V DC | ||||||||||||
1/8" | 1/16" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 5/8" | 2 1/8" | 2 | 1/8" | No | 00000000 | 0000000 |
3/16" | 1/8" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1" | 3 3/8" | 2 | 1/8" | No | 00000000 | 000000 |
3/8" | 1/4" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1 3/16" | 4" | 2 | 1/8" | No | 00000000 | 000000 |
Normally Closed—24V DC | ||||||||||||
1/8" | 1/16" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 5/8" | 2 1/8" | 2 | 1/8" | No | 00000000 | 000000 |
3/16" | 1/8" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1" | 3 3/8" | 2 | 1/8" | No | 00000000 | 000000 |
3/8" | 1/4" | 50A | 10 psi @ 140° F | Zero Pressure Drop | 15° to 140° | 1 3/16" | 4" | 2 | 1/8" | No | 00000000 | 000000 |
To stand up to aggressive and corrosive solutions in chemical-processing applications, these valves have a plastic body and a fluoroelastomer seal. They operate on electricity to automatically start and stop flow. Valves have union fittings on each end that separate into multiple pieces for easy installation and removal from your pipeline. They come with both threaded NPT fittings and unthreaded socket-connect female fittings.
All are normally closed unless actuated. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | No.of Mounting Slots | Mounting Slot Lg. | Fasteners Included | Each | |
Normally Closed—120V AC | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1/2 | Female | NPT | 2.3 | 120 psi @ 70° F | Zero Pressure Drop | 35° to 140° | 5 1/2" | 6 3/8" | 2 | 1/4" | No | 0000000 | 0000000 |
3/4 | Female | NPT | 3.2 | 120 psi @ 70° F | Zero Pressure Drop | 35° to 140° | 5 1/2" | 6 5/8" | 2 | 1/4" | No | 0000000 | 000000 |
1 | Female | NPT | 3.8 | 120 psi @ 70° F | Zero Pressure Drop | 35° to 140° | 5 1/2" | 6 5/8" | 2 | 1/4" | No | 0000000 | 000000 |
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | No.of Mounting Slots | Mounting Slot Lg. | Fasteners Included | Each | |
Normally Closed—120V AC | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1/2 | Female | NPT | 2.3 | 120 psi @ 70° F | Zero Pressure Drop | 35° to 190° | 5 5/16" | 6 3/8" | 2 | 1/4" | No | 0000000 | 0000000 |
3/4 | Female | NPT | 3.2 | 120 psi @ 70° F | Zero Pressure Drop | 35° to 190° | 5 1/2" | 6 5/8" | 2 | 1/4" | No | 0000000 | 000000 |
1 | Female | NPT | 3.8 | 120 psi @ 70° F | Zero Pressure Drop | 35° to 190° | 5 1/2" | 6 5/8" | 2 | 1/4" | No | 0000000 | 000000 |
Accurately and consistently dispense a specific amount of liquid—these actuated valves have a screen and buttons for programming batch size and calibration. They’ll automatically shut off once the set amount of liquid has been released.
Stainless steel valves have better corrosion resistance than brass valves, so they can be used with harsher chemicals.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Range, gpm | Pipe Schedule | Maximum Pressure | Maximum Temperature, °F | Maximum Current Draw, A | Valve Length | Height | Width | Specifications Met | Each | |
Normally Closed—120V AC | |||||||||||||
1/2 | Female | NPT | 2 to 22 | 40 | 145 psi @ 175° F | 140° | 0.06 | 10 3/8" | 5 3/8" | 3 5/16" | CSA Certified; IP65; UL Recognized | 0000000 | 000000000 |
3/4 | Female | NPT | 3 to 38 | 40 | 145 psi @ 175° F | 140° | 0.06 | 10 11/16" | 5 1/2" | 3 5/16" | CSA Certified; IP65; UL Recognized | 0000000 | 00000000 |
1 | Female | NPT | 5 to 62 | 40 | 145 psi @ 175° F | 140° | 0.06 | 11 7/8" | 5 3/4" | 3 5/16" | CSA Certified; IP65; UL Recognized | 0000000 | 00000000 |
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Range, gpm | Pipe Schedule | Maximum Pressure | Maximum Temperature, °F | Maximum Current Draw, A | Valve Length | Width | Height | Specifications Met | Each | |
Normally Closed—120V AC | |||||||||||||
1 1/2 | Female | NPT | 11 to 146 | 40 | 145 psi @ 175° F | 140° | 0.06 | 16 3/8" | 6" | 15 7/8" | CSA Certified; IP65; NEMA 4X; UL Recognized | 0000000 | 000000000 |
2 | Female | NPT | 18 to 241 | 40 | 145 psi @ 175° F | 140° | 0.06 | 17 3/4" | 6" | 16 3/4" | CSA Certified; IP65; NEMA 4X; UL Recognized | 0000000 | 00000000 |
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Range, gpm | Pipe Schedule | Maximum Pressure | Maximum Temperature, °F | Maximum Current Draw, A | Valve Length | Width | Height | Specifications Met | Each | |
Normally Closed—120V AC | |||||||||||||
1/2 | Female | NPT | 2 to 22 | 40 | 145 psi @ 175° F | 140° | 0.06 | 10 3/8" | 3 5/16" | 5 3/8" | CSA Certified; IP65; UL Recognized | 0000000 | 000000000 |
3/4 | Female | NPT | 3 to 38 | 40 | 145 psi @ 175° F | 140° | 0.06 | 10 11/16" | 3 5/16" | 5 1/2" | CSA Certified; IP65; UL Recognized | 0000000 | 00000000 |
1 | Female | NPT | 5 to 62 | 40 | 145 psi @ 175° F | 140° | 0.06 | 11 7/8" | 3 5/16" | 5 3/4" | CSA Certified; IP65; UL Recognized | 0000000 | 00000000 |
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Range, gpm | Pipe Schedule | Maximum Pressure | Maximum Temperature, °F | Maximum Current Draw, A | Valve Length | Width | Height | Specifications Met | Each | |
Normally Closed—120V AC | |||||||||||||
1 1/2 | Female | NPT | 11 to 146 | 40 | 145 psi @ 175° F | 140° | 0.06 | 16 3/8" | 6" | 15 7/8" | CSA Certified; IP65; NEMA 4X; UL Recognized | 0000000 | 000000000 |
2 | Female | NPT | 18 to 241 | 40 | 145 psi @ 175° F | 140° | 0.06 | 17 3/4" | 6" | 16 3/4" | CSA Certified; IP65; NEMA 4X; UL Recognized | 0000000 | 00000000 |