Voltage Voltage |
---|
|
For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
Body Material Body Material |
---|
|
Valve Starting Position Valve Starting Position |
---|
|
Actuation Actuation |
---|
![]() | Electric (Solenoid) |
Maximum Pressure Maximum Pressure |
---|
|
Pressure Drop Pressure Drop |
---|
|
Connection Style Connection Style |
---|
![]() | Threaded |
Valve Type Valve Type |
---|
|
Valve Function Valve Function |
---|
|
Thread Type Thread Type |
---|
|
Shape Shape |
---|
![]() | Straight |
Wire Connection Type Wire Connection Type |
---|
![]() | Wire Leads |
Mounting Orientation Mounting Orientation |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Connection Type Connection Type |
---|
![]() | Pipe |
Seat Material Seat Material |
---|
|
Seal Material Seal Material |
---|
|
Maximum Current Draw Maximum Current Draw |
---|
|
Actuator Housing Material Actuator Housing Material |
---|
|
More
Built to withstand the extreme cold of liquid nitrogen and liquid oxygen, these valves are cleaned and bagged for high-purity applications. They operate on electricity to automatically start and stop flow.
All valves are normally closed unless actuated. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
304 stainless steel valves are more corrosion resistant than brass and bronze valves.
Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation. Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
NEMA 2 valves resist light splashing water and dust. NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Normally Closed—120V AC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/8 | Female | NPT | 0.5 | 300 psi @ 70° F | Zero Pressure Drop | -320° to 355° | 1 3/4" | 3 1/8" | 00000000 | 0000000 |
1/4 | Female | NPT | 0.7 | 120 psi @ 70° F | Zero Pressure Drop | -320° to 355° | 1 3/4" | 3 1/8" | 00000000 | 000000 |
3/8 | Female | NPT | 3.5 | 125 psi @ 70° F | Pressure Drop Assisted | -320° to 355° | 2 1/2" | 4 7/8" | 00000000 | 000000 |
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Normally Closed—120V AC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/2 | Female | NPT | 3.5 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7 1/16" | 0000000 | 0000000 |
1/2 | Female | NPT | 3.5 | 200 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/4" | 7 1/16" | 0000000 | 000000 |
3/4 | Female | NPT | 7.5 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 3 1/2" | 7 3/8" | 0000000 | 000000 |
1 | Female | NPT | 13 | 110 psi @ -350° F | Zero Pressure Drop | -350° to 400° | 4 1/8" | 8 1/8" | 0000000 | 000000 |
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Dia. | O'all Ht. | Each | |
Normally Closed—120V AC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/4 | Female | NPT | 0.9 | 225 psi @ 120° F | Pressure Drop Assisted | -320° to 120° | 1 11/16" | 4 13/16" | 0000000 | 0000000 |
3/8 | Female | NPT | 1.9 | 225 psi @ 120° F | Pressure Drop Assisted | -320° to 120° | 1 11/16" | 4 13/16" | 0000000 | 000000 |
1/2 | Female | NPT | 1.1 | 225 psi @ 120° F | Pressure Drop Assisted | -320° to 120° | 1 11/16" | 5 1/4" | 0000000 | 000000 |