Thread Type Thread Type |
---|
Voltage Voltage | Show |
---|
|
Shape Shape |
---|
![]() | Tee |
Valve Function Valve Function |
---|
|
Flow Pattern Flow Pattern |
---|
![]() |
L-Pattern |
Actuation Actuation |
---|
![]() | Electric (Solenoid) |
Valve Type Valve Type |
---|
|
Body Material Body Material |
---|
|
Frequency Frequency |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | Wire Leads |
Number of Ports Number of Ports |
---|
|
Connection Style Connection Style |
---|
![]() | Threaded |
Pressure Drop Pressure Drop |
---|
|
Actuation Time Actuation Time |
---|
|
Actuator Housing Material Actuator Housing Material |
---|
|
Actuator Length Actuator Length |
---|
|
Actuator Width Actuator Width |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Actuated On/Off Valves
More
Compact Threaded Solenoid Diverting Valves


- For Use With: Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon
- Seal Material: Buna-N Rubber
Lower profile than other solenoid diverting valves and available in smaller pipe sizes, these are often used to automatically divert flow between ports in tight spots. They operate on electricity. All can direct flow from the side-port inlet to the side-port outlet or the top-port outlet. Valves cannot shut off flow. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is mounted directly to the valve body to minimize movement and reduce wear.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
60V AC, 120V AC | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Min. Pressure Drop Required | Max. Temp., °F | Actuation Time | Valve Lg. | O'all Ht. | Each | |
430 Stainless Steel Body with Wire Leads | |||||||||||
NPT Female × NPT Female × NPT Female | |||||||||||
1/8 | L-Pattern | 0.17 | 125 psi @ 185° F | Zero Pressure Drop | None | 165° | 0 sec. | 1 5/8" | 3 13/16" | 0000000 | 0000000 |
1/4 | L-Pattern | 0.095 | 125 psi @ 185° F | Zero Pressure Drop | None | 165° | 0 sec. | 1 5/8" | 3 13/16" | 0000000 | 000000 |
1/4 | L-Pattern | 0.17 | 125 psi @ 185° F | Zero Pressure Drop | None | 165° | 0 sec. | 1 5/8" | 3 13/16" | 0000000 | 000000 |