Sensitivity Sensitivity |
---|
|
Check the accuracy of horizontal and vertical surfaces with these precision-machined levels. They have two highly sensitive vials set at 90° angles for checking two planes at the same time.
Levels with heat-resistant insulation are protected from heat transfer that may affect level sensitivity.
V-groove provides stability on curved surfaces.
No. of Vials | Housing | Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Ht. | For Max. No. of Planes | Horizontal | Vertical | Sensitivity | Material | Color | Vial Material | Mounting Fasteners Included | No. of | Dia. | Features | Each | |
T | |||||||||||||||
3 5/32" | 2 9/16" | 0.667" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Cast Iron | __ | Glass | No | 2 | 0.22" | __ | 00000000 | 0000000 |
Square | |||||||||||||||
4" | 1 1/4" | 4" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 0000000 | 00000000 |
6" | 1 3/8" | 6" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 0000000 | 00000000 |
8" | 1 9/16" | 8" | 2 | 1 | 1 | 0.0006 in./ft., 0 min./0.1" | Cast Iron | Green | Glass | __ | __ | __ | V-Groove | 0000000 | 00000000 |
10" | 1 3/4" | 10" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 0000000 | 00000000 |
Triangular | |||||||||||||||
6" | 1 9/16" | 6" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 0000000 | 00000000 |
These levels come with a calibration certificate traceable to NIST that states they've passed a test for accuracy. They are precision-machined and check the accuracy of both horizontal and vertical surfaces simultaneously with two highly sensitive vials set at 90° angles.
Levels with heat-resistant insulation are protected from heat transfer that may affect level sensitivity.
V-groove provides stability on curved surfaces.
No. of Vials | Housing | Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Ht. | For Max. No. of Planes | Horizontal | Vertical | Sensitivity | Material | Color | Vial Material | Mounting Fasteners Included | No. of | Dia. | Features | Each | |
T | |||||||||||||||
3 5/32" | 2 9/16" | 0.667" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Cast Iron | __ | Glass | No | 2 | 0.22" | __ | 000000000 | 0000000 |
Square | |||||||||||||||
4" | 1 1/4" | 4" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 00000000 | 00000000 |
6" | 1 3/8" | 6" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 00000000 | 00000000 |
8" | 1 9/16" | 8" | 2 | 1 | 1 | 0.0006 in./ft., 0 min./0.1" | Cast Iron | Green | Glass | __ | __ | __ | V-Groove | 00000000 | 00000000 |
10" | 1 3/4" | 10" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 00000000 | 00000000 |
Triangular | |||||||||||||||
6" | 1 9/16" | 6" | 2 | 1 | 1 | 0.001 in./ft., 0 min./0.1" | Steel | __ | Glass | __ | __ | __ | V-Groove, Heat-Resistant Insulation | 00000000 | 00000000 |
Adjust a surface into a level position on multiple planes.
Two-plane levels have two vials set at 90° angles to allow you to level in two directions simultaneously.
Three-plane level has two vials set at 90° to allow you to level in two directions simultaneously, but also has a third vial for checking squareness.