Choosing an Electrical Switch
More
3/4" Panel-Mount Key Switches



Prevent accidental activation and limit access—these switches require a key to turn circuits on or off. All fit into a standard panel cutout.
Keyed alike switches all open with the same key.
Keyed differently switches each open with a unique key.
Keyed differently/master keyed switches are keyed differently but can be used with a master key (sold separately).
For technical drawings and 3-D models, click on a part number.
Switches | Replacement Keys | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of Keys Included | Key Removal Position | Each | Each | ||
2 Position with Metal Base | ||||||||||||||
Keyed Alike with Screw Terminals | ||||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 6 A @ 120 V AC | 240V AC | 7/8" | 1 3/4" | 2 | Center | 0000000 | 000000 | 0000000 | 00000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC | 240V AC | 7/8" | 1 1/2" | 2 | Center | 0000000 | 00000 | 0000000 | 0000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC | 240V AC | 7/8" | 1 1/2" | 2 | Center, Right | 0000000 | 00000 | 0000000 | 0000 |
Keyed Alike with Tab Terminals | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 4 A @ 125 V AC/24 V DC | 28V DC 125V AC | 7/8" | 1 1/16" | 2 | Center | 0000000 | 00000 | 000000 | 0000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 4 A @ 125 V AC/24 V DC | 28V DC 125V AC | 7/8" | 1 1/16" | 2 | Center, Right | 0000000 | 00000 | 000000 | 0000 |
2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPDT | 4 A @ 125 V AC/24 V DC | 28V DC 125V AC | 7/8" | 1 1/16" | 2 | Center | 0000000 | 00000 | 000000 | 0000 |
2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPDT | 4 A @ 125 V AC/24 V DC | 28V DC 125V AC | 7/8" | 1 1/16" | 2 | Center, Right | 0000000 | 00000 | 000000 | 0000 |
Keyed Alike with Wire Leads | ||||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 1/8" | 2 | Center | 00000000 | 00000 | 00000000 | 0000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 1/8" | 2 | Center, Right | 0000000 | 00000 | 0000000 | 0000 |
Keyed Differently with Wire Leads | ||||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 1/8" | 2 | Center | 00000000 | 00000 | 00000000 | 0000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 1/8" | 2 | Center, Right | 0000000 | 00000 | 0000000 | 0000 |
Switches | Master Keys | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of Keys Included | Key Removal Position | Each | Each | ||
2 Position with Metal Base | ||||||||||||||
Keyed Differently/Master Keyed with Wire Leads | ||||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 1/8" | 2 | Center | 00000000 | 000000 | 00000000 | 00000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 1/8" | 2 | Center, Right | 0000000 | 00000 | 0000000 | 0000 |
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of Keys Included | Key Removal Position | Each | |
3 Position with Metal Base | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Keyed Alike with Tab Terminals | ||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPST-NO | 4 A @ 125 V AC/24 V DC | 28V DC 125V AC | 7/8" | 1 1/16" | 2 | Left, Center, Right | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | SPST-NO | 4 A @ 125 V AC/24 V DC | 28V DC 125V AC | 7/8" | 1 1/16" | 2 | Center | 0000000 | 00000 |
2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Stays Switched (Maintained) | 8 | DPDT | 4 A @ 125 V AC/24 V DC | 28V DC 125V AC | 7/8" | 1 1/16" | 2 | Center | 0000000 | 00000 |
Washdown 3/4" Panel-Mount Key Switches


Rated NEMA 4 or IP66, these switches are protected from washdowns. They require a key to turn circuits on or off, limiting access to sensitive equipment. All fit into a standard panel cutout.
Keyed alike switches all open with the same key.
Keyed differently switches each open with a unique key.
For technical drawings and 3-D models, click on a part number.
Key Switches | Replacement Keys | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of Keys Included | Key Removal Position | Environmental Rating | Each | Each | ||
2 Position with Metal Base | |||||||||||||||
Keyed Alike with Screw Terminals | |||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 300 V AC/24 V DC | 24V DC 300V AC | 7/8" | 1 7/8" | 2 | Center, Right | NEMA 4, IP66 | 0000000 | 000000 | 000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 20 A @ 240 V AC | 690V AC | 7/8" | 2 5/8" | 2 | Center, Right | IP66 | 00000000 | 00000 | 000000 | 0000 |
Keyed Alike with Tab Terminals | |||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 4 A @ 125 V AC/28 V DC | 28V DC 125V AC | 7/8" | 1 1/4" | 2 | Center, Right | NEMA 4, IP66 | 0000000 | 00000 | 000000 | 0000 |
Keyed Differently with Screw Terminals | |||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 300 V AC/24 V DC | 24V DC 300V AC | 7/8" | 1 7/8" | 2 | Center, Right | NEMA 4, IP66 | 0000000 | 00000 | 000000 | 00 |
Keyed Differently with Tab Terminals | |||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 4 A @ 125 V AC/28 V DC | 28V DC 125V AC | 7/8" | 1 1/4" | 2 | Center, Right | NEMA 4, IP66 | 0000000 | 00000 | 000000 | 00 |
High-Security 3/4" Panel-Mount Key Switches

With a round key that is difficult to duplicate, these switches provide a higher degree of security than standard key switches.
Keyed alike switches all open with the same key.
Keyed differently switches each open with a unique key.
Keyed differently/master keyed switches are keyed differently but can be used with a master key (sold separately).
For technical drawings and 3-D models, click on a part number.
Switches | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Leads | Key | Replacement Keys | ||||||||||||||
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of | Lg. | No. of Keys Included | Removal Position | Each | Each | ||
2 Position with Metal Base | ||||||||||||||||
Keyed Alike with Wire Leads | ||||||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 3/16" | 2 | 10" | 2 | Center, Right | 0000000 | 000000 | 0000000 | 000000 |
Keyed Differently with Wire Leads | ||||||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 3/16" | 2 | 10" | 2 | Center, Right | 0000000 | 00000 | 0000000 | 00000 |
Keyed Differently/Master Keyed with Wire Leads | ||||||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 7 A @ 28 V DC/28 V AC | 28V DC 28V AC | 7/8" | 1 3/16" | 2 | 10" | 2 | Center, Right | 0000000 | 00000 | 000000 | 00 |
Master Key | 0000000 | Each | 00000 |
22 mm Panel-Mount Key Switches
Limit access to sensitive equipment—these switches require a key to actuate. They're rated IP66, IP69K, NEMA 3S, NEMA 4X, and NEMA 13, and are UL and C-UL Recognized Components. Switches include enough contact blocks to control the number of circuits listed. Contact blocks are rated IP20 and are UL and C-UL Listed. Use BACO legend plates (not included) to label switches.
Mounting tools (sold separately) make it easier to install switches in crowded panels.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | No. of Keys Included | Key Removal Position | Manufacturer | Each | |
2 Position with Plastic Base | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | |||||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | Black | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 3/16" | 1 11/16" | 6 | 2 | Left | BACO Controls | 000000 | 000000 |
Vibration-Resistant 22 mm Panel-Mount Key Switches

To prevent accidental actuation and limit access to sensitive equipment, these switches require a key to turn circuits on or off. The contact block and actuator are all one piece, so they won’t separate in high-vibration applications. Install them in a standard panel cutout. They’re keyed alike, so they will all open with the same key.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of Keys Included | Key Removal Position | Each | |
2 Position with Plastic Base | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | Black | 0.6 A @ 120 V AC, 0.22 A @125 V DC | 240V AC 250V DC | 1 1/8" | 1 11/16" | 2 | Left | 0000000 | 000000 |
3 Position with Plastic Base | |||||||||||||
With Screw Terminals | |||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | Black | 0.6 A @ 120 V AC, 0.22 A @125 V DC | 240V AC 250V DC | 1 1/8" | 1 11/16" | 2 | Center | 0000000 | 00000 |
Miniature 15/32" Panel-Mount Key Switches


Maximize space in a panel with these miniature switches. They require a key to turn circuits on or off, limiting access to sensitive equipment. All are keyed alike, so they open with the same key.
For technical drawings and 3-D models, click on a part number.
Wire Leads | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | Quick-Disconnect Tab Width | No. of | Lg. | No. of Keys Included | Key Removal Position | Each | |
2 Position with Metal Base | |||||||||||||||
Keyed Alike with Quick-Disconnect Terminals | |||||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 4 A @ 125 V AC/24 V DC | 28V DC 250V AC | 9/16" | 1 5/16" | 0.11" | __ | __ | 2 | Center | 00000000 | 000000 |
Keyed Alike with Wire Leads | |||||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 4 A @ 125 V AC/24 V DC | 28V DC 250V AC | 9/16" | 1 5/16" | __ | 2 | 6" | 2 | Center | 00000000 | 00000 |
30 mm Panel-Mount Key Switches
These switches require a key to turn circuits on or off, limiting access to sensitive equipment. Rated NEMA 6, 13, and IP66, they're protected from washdowns and oil/coolant spraying. All are keyed alike, so they open with the same key. They include enough contact blocks to control the number of circuits listed.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | No. of Keys Included | Key Removal Position | Each | |
2 Position with Metal Base | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 5/16" | 1 5/8" | 4 | 2 | Left | 0000000 | 0000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 5/16" | 1 5/8" | 4 | 2 | Left | 0000000 | 000000 |
Replacement Key | 00000000 | Each | 000000 |
No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Environmental Rating | Specifications Met | Each | |
1 | 1 Off (Normally Open) | 2 | SPST-NO | IP20 | CSA Certified, EN 60947-1, EN 60947-5-1, EN 60947-5-4, IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4 | 0000000 | 000000 |
1 | 1 On (Normally Closed) | 2 | SPST-NC | IP20 | CSA Certified, EN 60947-1, EN 60947-5-1, EN 60947-5-4, IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 4 | DPST-1NO/1NC | IP20 | CSA Certified, EN 60947-1, EN 60947-5-1, EN 60947-5-4, IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4 | 0000000 | 00000 |
Hazardous Location 30 mm Panel-Mount Key Switches
Designed for use near ignitable gases, fibers, and dust, these switches have a housing that seals in anything that could ignite flammable material. You’ll know they’re safe because they’re NEC Class 1, Division 2 Groups A-D and NEC Zone 1 Groups IIC-IIA certified for hazardous locations. These switches require a key to turn circuits on or off, preventing accidental actuation and limiting access to sensitive equipment. Since they’re keyed alike, all open with the same key. Install them in a standard panel cutout.
Switches that control two circuits come with a contact block for each circuit.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Key Removal Position | Each | |
2 Position with Plastic Base | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Screw Terminals | ||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left | 0000000 | 0000000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
3 Position with Plastic Base | ||||||||||||
Screw Terminals | ||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Center, Right | 0000000 | 000000 |

Key Number | Each | |
HW9Z-SKP | 0000000 | 000000 |
16 mm Panel-Mount Key Switches

Limit access to sensitive equipment—these switches require a key to actuate. Rated NEMA 4, 13, and IP65, they're protected from washdowns and oil/coolant spraying. All are keyed alike, so they open with the same key.
Mounting wrenches (sold separately) make it easier to install switches in crowded panels.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Quick-Disconnect Tab Wd. | No. of Keys Included | Key Removal Position | Each | |
2 Position with Plastic Base | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Quick-Disconnect Terminals | |||||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 4 | SPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 3 | 0.11" | 2 | Center | 00000000 | 000000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 4 | SPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 3 | 0.11" | 2 | Center, Right | 00000000 | 00000 |
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 6 | DPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 3 | 0.11" | 2 | Center, Right | 00000000 | 00000 |
3 Position with Plastic Base | |||||||||||||||
With Quick-Disconnect Terminals | |||||||||||||||
2 | 2 Off (Normally Open) | Springs Back (Momentary) | 6 | DPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 2 | 0.11" | 2 | Center | 00000000 | 00000 |
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 6 | DPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 2 | 0.11" | 2 | Left, Center, Right | 00000000 | 00000 |
High-Amp Outlet-Box-Mount Key Switches

Able to withstand high currents, these switches can be used with motors and pumps. They require a key to turn circuits on or off, limiting access to sensitive equipment. All are keyed alike, so they open with the same key.
For technical drawings and 3-D models, click on a part number.
Key | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Horsepower @ Switching Voltage | Dia. | No. of Keys Included | Keying | Removal Position | Each | |
2 Position with Metal Base | |||||||||||||
Keyed Alike with Screw Terminals | |||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 20 A @ 120 V AC | 277V AC | 1 hp @ 120 V AC | 7/8" | 2 | Keyed Alike | Center | 000000 | 0000000 |
Access-Delay Frame-Mounted Safety Switches


Delay access to hazardous areas until conditions are safe; use these switches with machines that take time to stop after they are turned off. Mount the switch to the door frame and mount the key to the door so that the key is inserted into the switch when the door is closed. When the door is pulled, the key is held in place with 225 lbs. of force until the switch receives a signal from a time-delay relay, motion sensor, or position sensor (not included) that the machine’s motion has stopped. After the motion has stopped, the key can be removed from the switch, releasing the access door. They’re often used with machine guards. All have positive-force, normally-closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick. They’re rated for protection from washdowns and temporary submersion.
Style A and B have a key entry on the top and side of the switch.
Emergency override keys (sold separately) bypass the access delay feature.
For technical drawings and 3-D models, click on a part number.
Housing | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Input Voltage | Holding Force, lbs. | Ht. | Wd. | Dp. | Wire Connection Type | Conduit Trade Size | Each | |
Positive-Force Normally Closed Contacts | ||||||||||||||||
A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 24V AC, 24V DC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 0000000 |
A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 110V AC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 000000 |
Emergency Override Key for Style A | 0000000 | Each | 000000 |
Key-Actuated Light Switches

Prevent accidental activation—these switches require a key to turn lights on and off. They’re keyed alike, so all switches actuate with the same key. They also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Color | Key Removal Position | No. of Keys Included | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Each | |
1 | Gray | Off, On | 1 | 2 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 |
1 | Gray | Off, On | 1 | 2 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 |
Replacement Key | 0000000 | Each | 00000 |
Multi-Way Key-Actuated Light Switches

Also known as three-way switches, these are often used in large, open workspaces and can be wired on opposite ends of the room to control lights on the same circuit. They work in pairs to control lights from two different locations. To prevent accidental activation, they require a key to turn lights on and off. They’re keyed alike, so all switches actuate with the same key. They also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.
Multi-Way Switch Type | No. of Circuits Controlled | Color | Key Removal Position | No. of Keys Included | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Each | |
3 Way | 1 | Gray | Off, On | 1 | 3 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 |
Replacement Key | 0000000 | Each | 00000 |
High-Security Key-Actuated Light Switches