Aluminum Enclosed Push-Button Switches
More lightweight than steel, these aluminum enclosed switches are rated NEMA 4X for protection from corrosion and washdowns. The push buttons are rated NEMA 13. The enclosures are rated IP66 and IP67, and are ATEX, IECEx, and CSA Certified for use in hazardous locations.
For technical drawings and 3-D models, click on a part number.
Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Max. Voltage | Conduit Trade Size | Environmental Rating | Each | |
With Screw Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1 Button | ||||||||||
1 Green Button with Vertical Line (SPST-NO) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 0000000 |
1 Red Button with Circle (SPST-NC) | 1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 000000 |
2 Buttons | ||||||||||
1 Green Button with Vertical Line (SPST-NO), 1 Red Button with Circle (SPST-NC) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 000000 |
3 Buttons | ||||||||||
1 Green Button with Up Arrow (SPST-NO), 1 Red Button with Circle (SPST-NC), 1 Green Button with Down Arrow (SPST-NO) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 000000 |
Hazardous Location Enclosed Push-Button Switches
Use these switches where ignitable gas and dust may be present. They're rated for use in hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Message (Actuator Color) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Industry Designation | Switching Current @ Voltage | Max. Voltage | Conduit Trade Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals | |||||||||||||
1 Mushroom Button | |||||||||||||
Stop (Red) | 1 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 3/16" | 0000000 | 0000000 |
1 Flush Button | |||||||||||||
Start (Black) | 1 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 5/16" | 0000000 | 000000 |
Hazardous Location Enclosed Lever Switches
Use these switches where ignitable gas, dust, and fibers may be present. They're UL and C-UL listed for hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuator Color | Message (Switch Position) | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Fasteners Included | No. of Holes | Hole Dia. | Each | |
3 Positions | |||||||||||||
With Screw Terminals | |||||||||||||
Gray | Hand (Left), Off (Center), Auto (Right) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | No | 2 | 5/16" | 0000000 | 0000000 |
Hazardous Location Relays
Sealed for safety, these relays are a good choice for hazardous locations where combustible or corrosive gases may be present.
Relays with screw terminals are considered interface relays, so they’re placed between your controller and components to isolate the input and output circuits. This means they protect your component from voltage spikes while amplifying the relay’s signal and reducing interference for reliable transmission. They are often used for switching applications, such as small motors and pilot lights. The included relay socket mounts on 35 mm DIN rail (also known as DIN 3 rail).
Relays with circular-pin terminals plug into relay sockets (sold separately) for easy installation. They are hermetically sealed.
Relay sockets mount to 35 mm DIN rail (also known as DIN 3 rail) or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Environmental Rating | Each | Each | ||
Screw Terminals | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
5 | 24V AC, 24V DC | 13.5 | 6 A @ 24 V AC/24 V DC | 26V AC/26V DC | __ | 3.5" | 0.2" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 | 000000 | 00 |
5 | 24V AC, 24V DC | 13.5 | 16 A @ 24 V AC/24 V DC | 26V AC/26V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
5 | 48V AC, 48V DC | 4 | 6 A @ 48 V AC/48 V DC | 52V AC/52V DC | __ | 3.5" | 0.2" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
5 | 48V AC, 48V DC | 4 | 16 A @ 48 V AC/48 V DC | 52V AC/52V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
5 | 120V AC, 120V DC | 3.5 | 6 A @ 120 V AC/120 V DC | 137V AC/137V DC | __ | 3.5" | 0.2" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
5 | 120V AC, 120V DC | 3.5 | 16 A @ 120 V AC/120 V DC | 137V AC/137V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
5 | 240V AC, 240V DC | 3.5 | 6 A @ 240 V AC/240 V DC | 264V AC/264V DC | __ | 3.5" | 0.2" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
5 | 240V AC, 240V DC | 3.5 | 16 A @ 240 V AC/240 V DC | 264V AC/264V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC, 24V DC | 13.5 | 8 A @ 24 V AC/24 V DC | 26V AC/26V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
8 | 48V AC, 48V DC | 4 | 8 A @ 48 V AC/48 V DC | 52V AC/52V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
8 | 120V AC, 120V DC | 3.5 | 8 A @ 120 V AC/120 V DC | 137V AC/137V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
8 | 240V AC, 240V DC | 3.5 | 8 A @ 240 V AC/240 V DC | 264V AC/264V DC | __ | 3.5" | 0.5" | 2.9" | IP20; NEC Class I Division 2 Groups A, B, C, D | 0000000 | 00000 | 000000 | 00 |
Circular-Pin Terminals | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 120V AC | 10 | 12 A @ 120 V AC/24 V DC | 300V AC | 1/3 hp @ 120 V AC | 1.6" | 1.4" | 2.1" | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 | 0000000 | 00000 |
8 | 24V DC | 38 | 12 A @ 120 V AC/24 V DC | 300V AC | 1/3 hp @ 120 V AC | 1.6" | 1.4" | 2.1" | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 | 0000000 | 0000 |
Hazardous Location Surface-Mount Temperature Switches
Safe for use in chemical plants, refineries, and other hazardous locations, these switches maintain your surface’s temperature by turning equipment on or off when they reach a set temperature. They’re FM approved for use where flammable gases may be present. These switches actuate when the temperature rises to the setpoint and reset when the temperature falls below the reset point. Since they're SPDT (single pole, double throw) switches, they control one circuit and can either be wired to turn one device from on to off (normally closed) or from off to on (normally open). Wire them normally closed to power a heater—when the temperature rises to the setpoint, the heater will turn off until the temperature falls below the reset point. Or wire them normally open to turn on alarms or other devices when the temperature rises above the setpoint. Their setpoint isn’t adjustable, so they’re easy to set up and there’s no risk of unintentional changes.
CSA-US and CSA certified, they also meet American and Canadian safety standards.
Mounting Holes | SPDT | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Actuation Point, °F | Actuation Tolerance | Approx. Difference Between Setpoint and Reset Point, °F | Max. Switching Current @ Voltage (Electrical Phase) | Ht. | Wd. | No. of | Dia. | Environmental Rating | Specifications Met | Each | |
Nonadjustable Rising Actuation Point | |||||||||||
47° | ±6° F | 10° | 15 A @ 240 V AC (Single) | 2 7/8" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 0000000 |
60° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
75° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
105° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
200° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
Differential Pressure Switches with Dial Indicator for Liquids
To check the difference in pressure between two points, these switches have a dial indicator that shows differential pressure in real time. The dial indicator operates independently of the switch. You’ll sometimes see these switches used to indicate a filter is clogged in a pump or cooling system. When the differential pressure reaches your setpoint, they turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
Rated NEMA 4X, these switches protect against dirt, washdown, and corrosion. They are also rated IP65 for protection from dust and rinsing. All are CSA certified, so they meet Canadian safety standards.
Setpoint | Approximate Difference Between Setpoint and Reset Point | Max. Input Pressure, psi | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/4 NPT Female Pipe Connection | ||||||||||
0-25 in. of H2O | 5 in. of H2O | 1,500 | ±2% | 250 mA @ 120 V AC | -20° to 175° | Brass | Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, Water | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEMA 4X | 0000000 | 0000000 |
0-1 psi | 0.2 psi | 1,500 | ±2% | 250 mA @ 120 V AC | -20° to 175° | Brass | Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, Water | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-5 psi | 1 psi | 1,500 | ±2% | 250 mA @ 120 V AC | -20° to 175° | Brass | Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, Water | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
3-15 psi | 3 psi | 5,000 | ±2% | 250 mA @ 120 V AC | -40° to 175° | Brass | Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, Water | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEMA 4X | 00000000 | 000000 |
6-30 psi | 6 psi | 5,000 | ±2% | 250 mA @ 120 V AC | -40° to 175° | Brass | Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, Water | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEMA 4X | 00000000 | 000000 |
10-50 psi | 10 psi | 5,000 | ±2% | 250 mA @ 120 V AC | -40° to 175° | Brass | Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, Water | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEMA 4X | 00000000 | 000000 |
Hazardous Location Flashlights
Rated for use in environments where hazardous material is present. These flashlights have built-in LEDs that last longer, are more efficient, and generate less heat than other light technologies.
Flashlights with a uniform beam are especially good for close-up tasks and inspection work. Flashlights with a bull’s eye beam have a bright center for long-distance illumination.
Flashlights that cannot be sold to the regions listed are restricted by local energy efficiency regulations.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Note: Battery life is significantly reduced when flashlights are used at the high-beam light setting.
Beam | O'all | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Flashlight Type | Brightness (Battery Life) | Light Setting | Distance, ft. | Color | Lg. | Dia. | Color | Environmental Rating | Cannot Be Sold To | Each | |
LED Bulbs—Fixed Beam Focus | ||||||||||||
A | Mini | 67 lumens (155 hrs.) | Momentary | 685 | White | 6 1/2" | 1 5/8" | Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | __ | 0000000 | 000000 |
A | Mini | 67 lumens (155 hrs.) | Momentary | 685 | White | 6 1/2" | 1 5/8" | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | __ | 0000000 | 00000 |
C | Standard | 130 lumens (4 hrs.) 50 lumens (12 hrs.) 1 lumens (480 hrs.) | High Beam Medium Beam Low Beam Strobe | 800 | White | 10 1/4" | 1 3/4" | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups F, G NEC Class III Divisions 1, 2 | Canada | 00000000 | 000000 |
Hazardous Location Pivoting-Head Flashlights
In addition to pivoting 210°, the light heads rotate 360° for directing light exactly where it’s needed. These flashlights are rated for use in environments where hazardous material is present. They’re also rated IP04 to withstand liquid splashed from all angles. With long-lasting, built-in LEDs, these flashlights are more efficient and generate less heat than flashlights with other light technologies. They cast a uniform beam that is especially good for close-up tasks and inspection work. Use the mounting magnet, clip, or retractable hook when you need to keep your hands free for work.
Rechargeable flashlight comes with a 120-volt AC charger that includes a 12-volt DC charging cord. This flashlight cannot be sold to Canada due to local energy efficiency regulations.
Note: Battery life is significantly reduced when flashlights are used at the high-beam light setting.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Beam | O'all | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Head Tilt | Brightness (Battery Life) | Light Setting | Rated Bulb Life, hrs. | Distance, ft. | Color | Lg. | Wd. | Dp. | Material | Color | Environmental Rating | Each | |
Flashlights | |||||||||||||
LED Bulbs | |||||||||||||
Fixed Beam Focus | |||||||||||||
210° | 163 lumens (3 hrs.) 50 lumens (12 hrs.) 1 lumens (480 hrs.) | High Beam Medium Beam Low Beam Strobe | 50,000 | 175 | White | 9 3/16" | 2 7/8" | 2 3/4" | Plastic | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups F, G NEC Class III Divisions 1, 2 IP04 | 000000 | 0000000 |
Rechargeable Flashlights | |||||||||||||
LED Bulbs | |||||||||||||
Fixed Beam Focus | |||||||||||||
210° | 163 lumens (3 hrs.) 50 lumens (12 hrs.) 1 lumens (480 hrs.) | High Beam Medium Beam Low Beam Strobe | 50,000 | 175 | White | 9 3/16" | 2 7/8" | 2 3/4" | Plastic | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups F, G NEC Class III Divisions 1, 2 IP04 | 000000 | 000000 |
Washdown Headlamps
Rated IP07, this headlamp withstands temporary submersion in a maximum of one meter of water for up to 30 minutes. It shines light on your work while keeping your hands free. This headlamp has long-lasting, built-in LEDs that produce more light and generate less heat than other light technologies. It casts a uniform beam that's especially good for close-up tasks and inspection work. Headlamps come on an adjustable elastic strap for normal wear. For secure wear over a hard hat, they also come with a rubber strap and snap-together fastener.
Headlamps with a battery life indicator let you know how close the batteries are to needing replacement. An LED light glows green when battery life is above 80%, yellow when it’s between 20% and 80%, and red when it’s below 20%.
Beam | O'all | Battery | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Head Tilt | Brightness (Battery Life) | Light Setting | Distance, ft. | Color | Pattern | Wd. | Dp. | Ht. | Color | Environment | Included | No. Required | Features | Each | ||
LED Bulbs | ||||||||||||||||
Adjustable Beam Focus | ||||||||||||||||
B | 90° | 200 lumens (100 hrs.) 25 lumens (150 hrs.) 650 lumens (72 hrs.) | High Beam Medium Beam Low Beam Strobe | 390 ft. | White | Uniform | 2 1/2" | 1 1/2" | 2" | Black | Hazardous Location, Temporary Submersion, Washdown | Yes | 4 | Battery Life Indicator | 0000000 | 000000 |
Hazardous Location Headlamps
Safe for use in environments where hazardous material is present, these headlamps shine light on your work while keeping your hands free. With built-in LEDs, they produce more light, are more efficient, and generate less heat than headlamps with other light technologies. All cast a uniform beam that is especially good for close-up tasks and inspection work.
Note: Battery life is significantly reduced when headlamps are used at the high-beam light setting.
Hazardous location environmental ratings indicate where manufactures have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Beam | O'all | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Head Tilt | Brightness (Battery Life) | Light Setting | Distance, ft. | Color | Wd. | Dp. | Ht. | Material | Strap Material | Color | Environmental Rating | Each | |
LED Bulbs | ||||||||||||||
Fixed Beam Focus | ||||||||||||||
A | 90° | 60 lumens (120 hrs.) 170 lumens (80 hrs.) | High Beam Low Beam | 240 | White | 1" | 1" | 3" | Plastic | Nylon | Black | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G IP07 | 0000000 | 000000 |
B | 90° | 300 lumens (80 hrs.) 65 lumens (115 hrs.) 30 lumens (121 hrs.) | High Beam Medium Beam Low Beam Strobe | 255 | White | 2" | 2 1/2" | 1 1/2" | Plastic | Nylon | Black | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G IP07 | 0000000 | 00000 |