Hazardous Location Enclosed Push-Button Switches
Use these switches where ignitable gas and dust may be present. They're rated for use in hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Message (Actuator Color) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Industry Designation | Switching Current @ Voltage | Max. Voltage | Conduit Trade Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals | |||||||||||||
1 Mushroom Button | |||||||||||||
Stop (Red) | 1 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 3/16" | 0000000 | 0000000 |
1 Flush Button | |||||||||||||
Start (Black) | 1 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 5/16" | 0000000 | 000000 |
1 Flush Button and 1 Projecting Button | |||||||||||||
Start (Green), Stop (Red) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 2 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 9/32" | 0000000 | 000000 |
Hazardous Location Enclosed Lever Switches
Use these switches where ignitable gas, dust, and fibers may be present. They're UL and C-UL listed for hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuator Color | Message (Switch Position) | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Fasteners Included | No. of Holes | Hole Dia. | Each | |
3 Positions | |||||||||||||
With Screw Terminals | |||||||||||||
Gray | Hand (Left), Off (Center), Auto (Right) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | No | 2 | 5/16" | 0000000 | 0000000 |
Hazardous Location Enclosed Motor Switches
Use these switches where ignitable gas and dust may be present. They're rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G for hazardous locations. Use them to turn motors on and off, or with other circuits such as lighting and electric heat circuits. They do not provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||||||
2 | Single (3 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 0000000 |
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000 |
Hazardous Location Differential Pressure Switches for Air
With an explosionproof enclosure that meets NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL and CSA for use where explosive gas or dust may be present. Often used with ovens, dryers, and HVAC systems, they can indicate a filter is clogged or help maintain a certain air pressure. These switches turn equipment on and off, activate automated controls, or signal alarms when the differential pressure reaches your setpoint. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
In addition to being UL listed and CSA certified, these switches are CE marked and FM approved, so they also meet European safety standards. They also are IP and NEMA rated for use outdoors and protect against dust and splashing water.
When measuring pressure in ductwork, pair them with a static pressure probe.
For technical drawings and 3-D models, click on a part number.
Setpoint Range | Approximate Difference Between Setpoint and Reset Point | Max. Input Pressure | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/8 NPT Female Pipe Connection | ||||||||||
0.07-0.15 in. of H2O | 0.13 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 0000000 |
0.15-0.5 in. of H2O | 0.05 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
0.4-1.6 in. of H2O | 0.18 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
1.4-5.5 in. of H2O | 0.35 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
3-11 in. of H2O | 0.45 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
4-20 in. of H2O | 0.5 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
0.5-2 psi | 0.3 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
1.5-8 psi | 1 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
3-15 psi | 0.9 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
4-25 psi | 0.7 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
15-50 psi | 1.25 psi | 70 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
Hazardous Location Line-Voltage Thermostats
Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present. Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | ||||||||||||
24V AC-277V AC | 22 | 50° to 90° | SPDT | 5 3/4" | 6 3/8" | 5 5/8" | No | 1/4" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 | 0000000 | 0000000 |
24V AC-277V AC | 22 | 50° to 90° | DPDT | 5 3/4" | 6 3/8" | 5 5/8" | No | 1/4" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 | 0000000 | 000000 |
Hazardous Location Vibration-Monitoring Switches
Get NEMA 4 and IP66 protection from dirt and water. Switch is rated for hazardous locations for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. If vibration or shock exceeds a set activation point, the contacts actuate to either shut down your machine or activate an alarm. Reset the switch with the push of a button. The activation point is adjustable between 0 to 5 gravity units (g) at 0 to 60 Hz.
Activation Point | Switching | Conduit | Mounting Slot | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, g | Frequency Range, Hz | Current, A | Voltage | Temp. Range, °F | Trade Size | Thread Type | Gender | Mounting Fasteners Included | Number of Mounting Holes | Lg. | Wd. | Environmental Rating | Each | |
1 Off (Normally Open) or 1 On (Normally Closed) Switch Starting Position | ||||||||||||||
SPDT | ||||||||||||||
0-5 | 0-60 | 15 | 125V AC 480V AC | -40° to 155° | 3/4 | NPT | Female | No | 4 | 3/4" | 3/8" | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G IP66 NEMA 4 | 0000000 | 0000000 |
Speed-Monitoring Switches
Set to a specific speed to detect unwanted machinery slowdown that can cause damage and downtime. Applications include drive trains, power-driven components, and conveyors. Switches are UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. They have an explosion-proof housing and are also rated NEMA 4X for washdown and corrosion protection.
Switching | Input | Conduit | Mounting Slot | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Activation Point Range, rpm | Current, A | Voltage | Voltage | Frequency, Hz | No. of Terminals | Trade Size | Thread Type | Gender | Lg. | Wd. | No. of | Mounting Fasteners Included | Environmental Rating | Each | |
1 Off (Normally Open), 1 On (Normally Closed) Starting Switch Position | |||||||||||||||
SPDT | |||||||||||||||
5-100 | 5 | 120V AC | 120V AC | 60 | 5 | 1 | NPT | Female | 1 1/4" | 0.32" | 2 | Yes | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4X | 0000000 | 0000000 |
Vertical-Mount Hazardous Location Float Switches for Fuels and Oils
For use in locations with flammable gases and combustible dust, this switch is UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount it vertically through the top of your tank. It’s rated NEMA 4 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Pipe | Float | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Lg. | Dia. | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | ||||||||||||||||||
316 Stainless Steel Body | ||||||||||||||||||
1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 275° | 9 1/4" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 10 A @ 120 V AC | 316 Stainless Steel | 4 1/2" | 1 5/8" | Wire Leads | 3/4 | NPT | Female | 0000000 | 000000000 |
Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils
Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall. All are rated NEMA 4 for protection from washdowns. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
Switches with stainless steel body are more corrosion resistant than switches with brass body.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Current | Float Material | Trade Size | Thread Type | Gender | Environmental Rating | Each | |
120V AC/240V AC Input Voltage | |||||||||||||||
Brass Body | |||||||||||||||
C | 1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 0° to 275° | 13 3/16" | 10 A @ 120 V AC | 316 Stainless Steel | 3/4 | NPT | Female | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G IP56 NEMA 4 | 0000000 | 0000000 |
316 Stainless Steel Body | |||||||||||||||
C | 1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 0° to 275° | 13 3/16" | 10 A @ 120 V AC | 316 Stainless Steel | 3/4 | NPT | Female | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G IP56 NEMA 4 | 0000000 | 00000000 |
Hazardous Location Float Switches for Water
For use in locations with flammable gases and combustible dust, this switch is UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount it vertically through the top of your tank. It’s rated NEMA 4 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Pipe | Float | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Lg. | Dia. | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | ||||||||||||||||||
Brass Body | ||||||||||||||||||
1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 275° | 5 1/4" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 10 A @ 120 V AC | 316 Stainless Steel | 4 1/2" | 1 5/8" | Wire Leads | 3/4 | NPT | Female | 0000000 | 0000000 |
1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 275° | 7 1/4" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 10 A @ 120 V AC | 316 Stainless Steel | 4 1/2" | 1 5/8" | Wire Leads | 3/4 | NPT | Female | 0000000 | 000000 |
1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 275° | 9 1/4" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 10 A @ 120 V AC | 316 Stainless Steel | 4 1/2" | 1 5/8" | Wire Leads | 3/4 | NPT | Female | 0000000 | 000000 |
2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 275° | 9 1/4" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 10 A @ 120 V AC | 316 Stainless Steel | 4 1/2" | 1 5/8" | Wire Leads | 3/4 | NPT | Female | 0000000 | 000000 |
Hazardous Location Float Switches for Chemicals
Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall.
Style B meets Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | |||||||||||||||||
316 Stainless Steel Body | |||||||||||||||||
B | 1 1/2 | NPT | Male | 0.4 | 1,500 psi @ 70° F | 0° to 300° | 3 1/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.83 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 0000000 | 0000000 |
B | 2 | NPT | Male | 0.4 | 1,500 psi @ 70° F | 0° to 300° | 3 1/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.83 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 0000000 | 000000 |
Level Switches for Dry Materials
When dry material rises to the level of the rotating paddle, these switches actuate. All are rated NEMA 4X and IP66 for protection from corrosion and washdowns.
Switches with auxiliary SPDT relay activate an alarm (not included).
For technical drawings and 3-D models, click on a part number.
Paddle | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Paddle Speed, rpm | Lg. | Wd. | Features | Environmental Rating | Specifications Met | Each | |
Horizontal Side Mount—0-30 lbs. per cu. ft. Capacity | |||||||||||||
8 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 6 5/8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 7" | 2" | Auxiliary SPDT Relay LED Alarm Status Indicator LED Power Indicator | IP66, NEMA 4X, NEC Class I Divisions 1, 2 Groups C, D, NEC Class II Divisions 1, 2 Groups E, F, G | UL Listed C-UL Listed | 00000000 | 0000000 |
20 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 6 5/8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 7" | 2" | __ | IP66, NEMA 4X, NEC Class I Divisions 1, 2 Groups C, D, NEC Class II Divisions 1, 2 Groups E, F, G | UL Listed C-UL Listed | 00000000 | 000000 |
Vertical Top Mount—30-70 lbs. per cu. ft. Capacity | |||||||||||||
8 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 12" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 5" | 1 1/2" | Auxiliary SPDT Relay LED Alarm Status Indicator LED Power Indicator | IP66, NEMA 4X, NEC Class I Divisions 1, 2 Groups C, D, NEC Class II Divisions 1, 2 Groups E, F, G | UL Listed C-UL Listed | 00000000 | 000000 |
20 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 12" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 5" | 1 1/2" | __ | IP66, NEMA 4X, NEC Class I Divisions 1, 2 Groups C, D, NEC Class II Divisions 1, 2 Groups E, F, G | UL Listed C-UL Listed | 00000000 | 000000 |
Paddle Material | Each | |
316 Stainless Steel | 00000000 | 000000 |
Voltage | Includes | Each | |
120V AC | Bracket, Washer | 00000000 | 0000000 |
Hazardous Location Insertion Flow Switches
Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. They are UL listed and CSA certified for use in hazardous locations. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline. They actuate when your system’s liquid pushes the paddle into a set position. To change your set point, the paddle has multiple layers that you can remove. For the lowest set point, use the largest paddle that will fit your pipe. To increase your set point, loosen the locking washers and remove paddles. You can trim the paddles to fine-tune your set point. The smaller the paddle, the higher the setpoint.
They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle.
These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
SPDT (singe pole, double throw) switches can turn one device from off to on (normally open) or from on to off (normally closed).
DPDT (double pole, double throw) switches can either turn two devices from off to on (normally open) or on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Set Point Range | Max. Flow Rate | Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | For Pipe Size | For Water and Oil, gpm | For Air and Inert Gas, scfm | For Water and Oil, gpm | For Air and Inert Gas | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Trade Size | Thread Type | Gender | Body Ht. | Each | |
SPDT | ||||||||||||||||
Brass Body | ||||||||||||||||
1 1/2 | NPT | Male | 1 1/2 2 4 12 20 | 3 to 7 4 to 15 12 to 95 140 to 900 400 to 2,400 | 17 to 32 13 to 65 50 to 400 800 to 3,450 2,850 to 10,000 | 55 97 391 3,525 9,792 | Not Rated | 1000 psi @ 70° F | -4° to 275° | 5 A @ 125 V AC 5 A @ 250 V AC | 3/4 | NPT | Female | 8" | 00000000 | 0000000 |
316 Stainless Steel Body | ||||||||||||||||
1 1/2 | NPT | Male | 1 1/2 2 4 12 20 | 3 to 7 4 to 15 12 to 95 140 to 900 400 to 2,400 | 17 to 32 13 to 65 50 to 400 800 to 3,450 2,850 to 10,000 | 55 97 391 3,525 9,792 | Not Rated | 2000 psi @ 70° F | -4° to 275° | 5 A @ 125 V AC 5 A @ 250 V AC | 3/4 | NPT | Female | 8" | 00000000 | 00000000 |
DPDT | ||||||||||||||||
Brass Body | ||||||||||||||||
1 1/2 | NPT | Male | 1 1/2 2 4 12 20 | 3 to 7 4 to 15 12 to 95 140 to 900 400 to 2,400 | 17 to 32 13 to 65 50 to 400 800 to 3,450 2,850 to 10,000 | 55 97 391 3,525 9,792 | Not Rated | 1000 psi @ 70° F | -4° to 275° | 5 A @ 125 V AC 5 A @ 250 V AC | 3/4 | NPT | Female | 8" | 00000000 | 000000 |
316 Stainless Steel Body | ||||||||||||||||
1 1/2 | NPT | Male | 1 1/2 2 4 12 20 | 3 to 7 4 to 15 12 to 95 140 to 900 400 to 2,400 | 17 to 32 13 to 65 50 to 400 800 to 3,450 2,850 to 10,000 | 55 97 391 3,525 9,792 | Not Rated | 2000 psi @ 70° F | -4° to 275° | 5 A @ 125 V AC 5 A @ 250 V AC | 3/4 | NPT | Female | 8" | 00000000 | 00000000 |
Hazardous Location Flashlights
Rated for use in environments where hazardous material is present. These flashlights have built-in LEDs that last longer, are more efficient, and generate less heat than other light technologies.
Flashlights with a uniform beam are especially good for close-up tasks and inspection work. Flashlights with a bull’s eye beam have a bright center for long-distance illumination.
Flashlights that cannot be sold to the regions listed are restricted by local energy efficiency regulations.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Note: Battery life is significantly reduced when flashlights are used at the high-beam light setting.
Beam | O'all | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Flashlight Type | Brightness (Battery Life) | Light Setting | Distance, ft. | Color | Lg. | Dia. | Color | Environmental Rating | Cannot Be Sold To | Each | |
LED Bulbs—Fixed Beam Focus | ||||||||||||
A | Mini | 67 lumens (155 hrs.) | Momentary | 685 | White | 6 1/2" | 1 5/8" | Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | __ | 0000000 | 000000 |
A | Mini | 67 lumens (155 hrs.) | Momentary | 685 | White | 6 1/2" | 1 5/8" | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | __ | 0000000 | 00000 |
C | Standard | 130 lumens (4 hrs.) 50 lumens (12 hrs.) 1 lumens (480 hrs.) | High Beam Medium Beam Low Beam Strobe | 800 | White | 10 1/4" | 1 3/4" | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups F, G NEC Class III Divisions 1, 2 | Canada | 00000000 | 000000 |
Hazardous Location Pivoting-Head Flashlights
In addition to pivoting 210°, the light heads rotate 360° for directing light exactly where it’s needed. These flashlights are rated for use in environments where hazardous material is present. They’re also rated IP04 to withstand liquid splashed from all angles. With long-lasting, built-in LEDs, these flashlights are more efficient and generate less heat than flashlights with other light technologies. They cast a uniform beam that is especially good for close-up tasks and inspection work. Use the mounting magnet, clip, or retractable hook when you need to keep your hands free for work.
Rechargeable flashlight comes with a 120-volt AC charger that includes a 12-volt DC charging cord. This flashlight cannot be sold to Canada due to local energy efficiency regulations.
Note: Battery life is significantly reduced when flashlights are used at the high-beam light setting.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Beam | O'all | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Head Tilt | Brightness (Battery Life) | Light Setting | Rated Bulb Life, hrs. | Distance, ft. | Color | Lg. | Wd. | Dp. | Material | Color | Environmental Rating | Each | |
Flashlights | |||||||||||||
LED Bulbs | |||||||||||||
Fixed Beam Focus | |||||||||||||
210° | 163 lumens (3 hrs.) 50 lumens (12 hrs.) 1 lumens (480 hrs.) | High Beam Medium Beam Low Beam Strobe | 50,000 | 175 | White | 9 3/16" | 2 7/8" | 2 3/4" | Plastic | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups F, G NEC Class III Divisions 1, 2 IP04 | 000000 | 0000000 |
Rechargeable Flashlights | |||||||||||||
LED Bulbs | |||||||||||||
Fixed Beam Focus | |||||||||||||
210° | 163 lumens (3 hrs.) 50 lumens (12 hrs.) 1 lumens (480 hrs.) | High Beam Medium Beam Low Beam Strobe | 50,000 | 175 | White | 9 3/16" | 2 7/8" | 2 3/4" | Plastic | Yellow/Black | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups F, G NEC Class III Divisions 1, 2 IP04 | 000000 | 000000 |