Clear All
Actuator Style Actuator Style |
---|
![]() | Rotary |
System of Measurement System of Measurement |
---|
|
Shaft Diameter Shaft Diameter |
---|
|
Switch Action Switch Action |
---|
|
Material Material |
---|
|
For Panel Cutout Diameter For PanelCutout Diameter | Show |
---|
|
For Panel Cutout Diameter For Panel Cutout Diameter | Hide |
---|
Shaft Length Shaft Length |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Screw Terminals | Solder |
Mounting Location Mounting Location |
---|
|
Overall Diameter Overall Diameter |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
For Maximum Panel Thickness For Maximum Panel Thickness |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Set Time Set Time |
---|
|
Timing Adjustment Style Timing Adjustment Style |
---|
![]() | Knob |
Choosing an Electrical Switch
More
Rotary Switches

For 13/32" Panel Cutout Dia.
Control multiple devices with one switch. Turn the shaft to change switch positions. Each position closes a set of contacts per circuit, so you can select between multiple devices on one or more circuits.
Switches for 13/32" panel cutout diameter require a knob.
For technical drawings and 3-D models, click on a part number.
Shaft | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Action | No. of Positions | No. of Terminals | Dp. Behind Panel | O'all Dia. | Lg. | Dia. | Each | ||
Plastic | ||||||||||
With Solder Lugs for 13/32" Panel Cutout Dia. | ||||||||||
1 | Stays Switched (Maintained) | 12 | 13 | 13/16" | 1" | 1 1/2" | 1/4" | 2.5 A @ 125 V AC, 0.35 A @ 125 V DC | 00000000 | 000000 |
2 | Stays Switched (Maintained) | 6 | 14 | 13/16" | 1" | 1 1/2" | 1/4" | 2.5 A @ 125 V AC, 0.35 A @ 125 V DC | 00000000 | 00000 |
3 | Stays Switched (Maintained) | 4 | 15 | 13/16" | 1" | 1 1/2" | 1/4" | 2.5 A @ 125 V AC, 0.35 A @ 125 V DC | 00000000 | 00000 |
4 | Stays Switched (Maintained) | 3 | 16 | 13/16" | 1" | 1 1/2" | 1/4" | 2.5 A @ 125 V AC, 0.35 A @ 125 V DC | 00000000 | 00000 |
Panel-Mount Timer Switches

20 Amp
Install these switches in a panel cutout to automatically turn electrical equipment on or off after a set interval.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Input Voltage | Dia. | Dp. | For Panel Cutout Dia. | For Max. Panel Thick. | Wire Connection Type | No. of Terminals | Each | |
Dial Reset | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 20 A @ 120 V AC/240 V AC | 1 min.-15 min. | 120V AC/240V AC | 2 9/16" | 1 9/16" | 13/32" | 1/8" | Screw Terminals | 3 | 0000000 | 0000000 |
Replacement Knob for 20A Switches | 0000000 | Each | 00000 |