Actuator Style Actuator Style |
|---|
![]() | |
| Push Button | Toggle |
Switch Action Switch Action |
|---|
|
Power Power |
|---|
Wire Connection Type Wire Connection Type |
|---|
![]() | |
| Quick- Disconnect Terminals | Screw Terminals |
| Wire Leads |
System of Measurement System of Measurement |
|---|
|
For Panel Cutout Diameter For PanelCutout Diameter | Show |
|---|
|
For Panel Cutout Diameter For Panel Cutout Diameter | Hide |
|---|
Switch Type Switch Type |
|---|
|
Push-Button Style Push-Button Style |
|---|
![]() | Mushroom |
Switch Starting Position Switch Starting Position |
|---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
Choosing an Electrical Switch
More
Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Push-Pull Switches


The lever sticks out further than a push button, making it easy to identify the position of these switches. They're often used in marine environments.
Switches with a sealed body provide extra protection from moisture and dirt.
Three-position switches close one contact when pulled to the middle position, and close two contacts when pulled all the way.
For technical drawings and 3-D models, click on a part number.
Wire Leads | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switch Position (Function) | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of | Lg. | Each | |
Brass Actuator with Screw Terminals | |||||||||||||
2 Positions | |||||||||||||
| 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 3 | SPST-NO | In (Off), Out (On) | 10 A @ 12 V DC | 24V DC | 3/4" | 2 1/8" | __ | __ | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | In (Off or On), Out (On or Off) | 10 A @ 12 V DC | 24V DC | 7/8" | 2 1/8" | __ | __ | 0000000 | 00000 |
3 Positions | |||||||||||||
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | In (Off), Center (On), Out (On) | 10 A @ 12 V DC | 24V DC | 3/4" | 2 7/8" | __ | __ | 0000000 | 00000 |
Brass Actuator with Wire Leads and Sealed Body | |||||||||||||
2 Positions | |||||||||||||
| 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | In (Off), Out (On) | 10 A @ 12 V DC | 24V DC | 7/8" | 2" | 2 | 8" | 0000000 | 00000 |
Panel-Mount Timer Switches

Install these switches in a panel cutout to automatically turn electrical equipment on or off after a set interval.
Switches with set time recall retain the last setting; push the button to start the timer over at the same interval, eliminating the need to reset the dial with every use.
Wire Leads | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Input Voltage | Dia. | Dp. | For Panel Cutout Dia. | For Max. Panel Thick. | Wire Connection Type | No. of Terminals | No. of | Lg. | Each | |
Dial Reset | ||||||||||||||
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 0000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
Push Reset with Set Time Recall | ||||||||||||||
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
Panel-Mount Compact Disconnect Switches

Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included). They’re rated IP65 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Yellow Plastic Housing with Red Actuator | ||||||||
|---|---|---|---|---|---|---|---|---|
| Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
| 12 A @ 600 V AC, 16 A @ 24 V DC | 3PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
| 16 A @ 600 V AC, 20 A @ 24 V DC | 3PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 00000 |
| 20 A @ 600 V AC, 25 A @ 24 V DC | 3PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 00000 |
| 25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
| 50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
| 63 A @ 600 V AC, 80 A @ 24 V DC | 3PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
| 12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, CSA Certified | 00000000 | 00000 |
| 16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, CSA Certified | 00000000 | 00000 |
| 20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, CSA Certified | 00000000 | 00000 |
| 25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, CSA Certified | 00000000 | 000000 |
| 50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, CSA Certified | 00000000 | 000000 |
| 63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, CSA Certified | 00000000 | 000000 |
Panel-Mount Disconnect Switches
Install these switches in a panel cutout. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All are UL listed, C-UL listed, and CE marked—they meet American, Canadian, and European safety standards.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
Terminal covers prevent contact with live terminals.
For technical drawings and 3-D models, click on a part number.


Switching | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Current, A | Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Environmental Rating | Each | |
Yellow Plastic Housing with Red Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
| 25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 000000 |
| 32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 00000 |
| 50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 00000 |
| 63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 00000 |
| 80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
| 100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
| 25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
| 32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
| 50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
| 63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
| 80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
| 100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
Gray Plastic Housing with Gray Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
| 25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 00000 |
| 32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 00000 |
| 50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 00000 |
| 63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 00000 |
| 80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
| 100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
| 25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
| 32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
| 50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
| 63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
| 80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
| 100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
| "Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 00000 |

| Switching Current, A | Each | |
| 10 | 0000000 | 000000 |
Single-Action Air Directional Control Valves

Manually control these valves by pushing or turning the actuator. Also known as 3-way or 3/2 valves, they create one action, such as extending a cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves block airflow until actuated.
Valves with hand return actuation stay actuated and go back to their starting position only when you move the actuator again.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.

Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Flow Ports | For Inlet Tube ID | For Outlet Tube ID | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | ||
Normally Closed Flow Positions | |||||||||||||||
Hand Return Actuation | |||||||||||||||
| G | 3 | 1/16" | 1/16" | Barbed | 2.2 | 0.04 | 0-125 | 20 | 5/8" | 3/8" | 1 5/8" | 3/8" | Yes | 00000000 | 000000 |
Heavy Duty Flexible Shafts

With a strong steel core, a protective plastic case, and bearings, these shafts handle the demands of high-torque applications. They snake around curves and obstructions to transmit rotary motion along any path. Rotate manually with a knob (not included) or mechanically.
Secure female fittings by tightening the set screw.
Male fittings attach to a panel. Push the male end of the shaft through a panel cutout and secure with locknuts. Fittings have a D-profile for fastening to a manual control knob.
Max. Torque, in.-lbs. | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| O'all Lg., ft. | For Shaft Dia. | OD | For Panel Cutout Dia. | Max. Speed, rpm | Clockwise Drive | Counterclockwise Drive | Bend Radius | Material | Fitting Material | Bearing Material | Max. Temp., °F | Each | |
Male × Female | |||||||||||||
With Sleeve Bearings | |||||||||||||
| 3 | 1/4" | 25/64" | 3/8" | 200 | 65 | 45 | 5" | Plastic-Coated Steel | Zinc-Plated Steel | Bronze | 190° | 0000000 | 0000000 |
| 4 | 1/4" | 25/64" | 3/8" | 200 | 65 | 45 | 5" | Plastic-Coated Steel | Zinc-Plated Steel | Bronze | 190° | 0000000 | 000000 |
| 6 | 1/4" | 25/64" | 3/8" | 200 | 65 | 45 | 5" | Plastic-Coated Steel | Zinc-Plated Steel | Bronze | 190° | 0000000 | 000000 |
Flexible Shafts
Made of steel, these shafts are stronger than stainless steel flexible shafts. They snake around curves and obstructions to transmit rotary motion along any path. Rotate manually with a knob (not included) or mechanically.
Secure female fittings by tightening the set screw.
Male fittings attach to a panel. Push the male end of the shaft through a panel cutout and secure with locknuts. Fittings have a D-profile for fastening to a manual control knob.
Max. Torque, in.-lbs. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Lg., ft. | For Shaft Dia. | OD | For Panel Cutout Dia. | Max. Speed, rpm | Clockwise Drive | Counterclockwise Drive | Bend Radius | Material | Fitting Material | Each | |
Male × Female | |||||||||||
| 1/2 | 1/4" | 1/8" | 3/8" | 200 | 20 | 14 | 3" | Steel | Zinc-Plated Steel | 0000000 | 000000 |
| 1 | 1/4" | 1/8" | 3/8" | 200 | 20 | 14 | 3" | Steel | Zinc-Plated Steel | 0000000 | 00000 |
| 1 | 1/4" | 3/16" | 3/8" | 200 | 65 | 45 | 5" | Steel | Zinc-Plated Steel | 0000000 | 00000 |
| 1 1/2 | 1/4" | 1/8" | 3/8" | 200 | 20 | 14 | 3" | Steel | Zinc-Plated Steel | 0000000 | 00000 |
| 1 1/2 | 1/4" | 3/16" | 3/8" | 200 | 65 | 45 | 5" | Steel | Zinc-Plated Steel | 0000000 | 000000 |
| 2 | 1/4" | 1/8" | 3/8" | 200 | 20 | 14 | 3" | Steel | Zinc-Plated Steel | 0000000 | 00000 |
| 2 | 1/4" | 3/16" | 3/8" | 200 | 65 | 45 | 5" | Steel | Zinc-Plated Steel | 0000000 | 000000 |
| 3 | 1/4" | 1/8" | 3/8" | 200 | 20 | 14 | 3" | Steel | Zinc-Plated Steel | 0000000 | 00000 |
| 3 | 1/4" | 3/16" | 3/8" | 200 | 65 | 45 | 5" | Steel | Zinc-Plated Steel | 0000000 | 000000 |