Industry Designation Industry Designation | Show |
---|
|
Industry Designation Industry Designation | Hide |
---|
Number of Circuits Controlled Number of Circuits Controlled |
---|
|
Actuator Style Actuator Style |
---|
![]() | Toggle |
Wire Connection Type Wire Connection Type |
---|
|
Switch Starting Position Switch Starting Position |
---|
|
Switch Action Switch Action |
---|
|
Switch Type Switch Type |
---|
|
System of Measurement System of Measurement |
---|
|
Mounting Location Mounting Location |
---|
|
Power Power |
---|
Toggle Style Toggle Style |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Mounting Hardware Included Mounting Hardware Included |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Choosing an Electrical Switch
More
Toggle Switches

Switches with an on-on or on-(on) position designation alternate power between sets of terminals.
To view switch wiring diagrams, select a part number and click Product Detail.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | For Max. Panel Thick. | Mounting Hardware Included | Choose a Wire Connection Type | Each | |
2 Position with Rounded Toggle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For 1/2" Panel Cutout Dia. | ||||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 15 A @ 125 V AC/28 V DC | 28V DC 250V AC | 0.13" | Yes | 00000000 | 000000 |
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | For Max. Panel Thick. | Mounting Hardware Included | Choose a Wire Connection Type | Each | |
3 Position with Rounded Toggle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For 1/2" Panel Cutout Dia. | ||||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 15 A @ 125 V AC/28 V DC | 28V DC 250V AC | 0.13" | Yes | 00000000 | 000000 |
Miniature Toggle Switches

Maximize the space in a panel—these switches are half the size of most toggle switches.
Switches with an on-on or on-(on) position designation alternate power between sets of terminals.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | Dp. Behind Panel | Mounting Hardware Included | Wire Connection Type | Each | |
2 Position with Rounded Toggle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For 1/4" Panel Cutout Dia. | ||||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 6 A @ 125 V AC, 4 A @ 30 V DC | 30V DC 250V AC | 0.66" | Yes | Solder Lugs | 0000000 | 000000 |
High-Current Toggle Switches

Able to withstand high currents, these switches are often used with motors and pumps.
Switches with an on-on position designation alternate power between sets of terminals.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | Dp. Behind Panel | Mounting Hardware Included | Each | |
2 Position with Quick-Disconnect Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 20 A @ 125 V AC, 20 A @ 30 V DC | 30V DC 250V AC | 1.31" | Yes | 0000000 | 000000 |
2 Position with Screw Terminals | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 30 A @ 125 V AC/30 V DC | 30V DC 250V AC | 1.34" | Yes | 0000000 | 00000 |
3 Position with Quick-Disconnect Terminals | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 20 A @ 125 V AC, 20 A @ 30 V DC | 30V DC 250V AC | 1.31" | Yes | 0000000 | 00000 |
3 Position with Screw Terminals | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 30 A @ 125 V AC/30 V DC | 30V DC 250V AC | 1.34" | Yes | 0000000 | 00000 |
3 Position with Solder Lugs | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 20 A @ 125 V AC, 20 A @ 30 V DC | 30V DC 250V AC | 1.08" | Yes | 0000000 | 00000 |
Durable Disconnect Switches

Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
Use switches with a fuse holder where overload protection is needed. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
Swithes with safety interlock keep the door closed when the switch is on, and prevent the switch from turning on when the door is open.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | For No. of Wires | For Fuse Class | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
Enamel-Coated Steel with Black Actuator | ||||||||||||
3 Circuits with Lockout, Safety Interlock | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 600 V AC) Single (5 hp @ 240 V AC) Single (7 1/2 hp @ 480 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 0000000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 240 V AC) Single (25 hp @ 480 V AC) Single (30 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 000000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (20 hp @ 240 V AC) Single (40 hp @ 480 V AC) Single (40 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (3 hp @ 240 V AC) Three (5 hp @ 480 V AC) Three (7 1/2 hp @ 600 V) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (5 hp @ 480 V AC) Three (15 hp @ 480 V AC) Three (15 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 480 V AC) Three (25 hp @ 480 V AC) Three (30 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
Compact Spade-Terminal Relays

Smaller than standard spade-terminal relays in height and depth, these relays save space inside your control cabinet. Attach quick-disconnect terminals or plug relays into relay sockets.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current | Relay Sockets | ||||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | @ 120V AC | @28V DC | Max. Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Features | Specifications Met | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||||
11 | 24V AC | 63 | 15A | 12A | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 000000 | 0000000 | 000000 |
11 | 120V AC | 13 | 15A | 12A | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 6 | 15A | 12A | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 117 | 15A | 12A | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 58 | 15A | 12A | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | LED Indicating Light, Lockable Test Button, Mechanical Flag Indicator | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 00000000 | 00000 | 0000000 | 00000 |
Flange-Mount Spade-Terminal Relays

Mount relays to a flat surface using the slot on the flange and attach quick-disconnect terminals, or plug relays into relay sockets.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 110V AC/24V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||
11 | 24V AC | 67 | 10A | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | UL Recognized Component CSA Certified | 00000000 | 000000 | 0000000 | 000000 |
11 | 120V AC | 13 | 10A | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | UL Recognized Component CSA Certified | 00000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 59 | 10A | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | UL Recognized Component CSA Certified | 00000000 | 00000 | 0000000 | 00000 |
Spade-Terminal Relays


Attach quick-disconnect terminals or plug these relays into relay sockets. Also known as ice cube relays.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||
11 | 12V AC | 230 | 15A | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 000000 | 0000000 | 000000 |
11 | 24V AC | 115 | 15A | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 24 | 15A | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 12 | 15A | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 100 | 15A | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 51 | 15A | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
Circular-Pin Relays


The circular pin terminals plug into relay sockets for easy installation. Also known as ice cube relays.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
Relays | Relay Sockets | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | Ht. | Wd. | Dp. | Features | Specifications Met | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 24V AC | 96 | 10A | 1.4" | 1.4" | 2.1" | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 | 0000000 | 00000 |
11 | 120V AC | 19 | 10A | 1.4" | 1.4" | 2.1" | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
11 | 120V AC | 19 | 10A | 1.4" | 1.4" | 2.1" | LED Power Indicator | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
11 | 240V AC | 9 | 10A | 1.4" | 1.4" | 2.1" | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
11 | 12V DC | 112 | 10A | 1.4" | 1.4" | 2.1" | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
11 | 24V DC | 55 | 10A | 1.4" | 1.4" | 2.1" | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
Premium Circular-Pin Relays


Built to handle tough, repetitive-use applications, these are more durable than standard relays. The circular pin terminals plug into relay sockets for easy installation. Also known as ice cube relays.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
Relays | Relay Sockets | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC/28V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 24V AC | 84 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 000000 | 0000000 | 00000 |
11 | 120V AC | 18 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
11 | 240V AC | 9 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
11 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 0000 |
11 | 24V DC | 52 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 0000 |