Thread Type Thread Type |
---|
Body Material Body Material |
---|
|
Set Point Set Point |
---|
Connection Style Connection Style |
---|
![]() |
Threaded |
![]() |
Compression |
Maximum Pressure Maximum Pressure |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Mounting Orientation Mounting Orientation |
---|
|
Current Current |
---|
|
Mounting Location Mounting Location | Show |
---|
|
Mounting Location Mounting Location | Hide |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
Set Point Configuration Set Point Configuration |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Switch Starting Position Switch Starting Position |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
System of Measurement System of Measurement |
---|
|
About Flowmeters and Totalizers
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
Hazardous Location Flow Switches for Water, Air, and Inert Gas

These switches are UL listed for environments with flammable gases and combustible dust. They activate or deactivate equipment when the flow rate reaches your set point. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
Switches with a brass body meet NEC Class I, Divisions 1 and 2, Groups B, C, and D; and NEC Class II, Divisions 1 and 2, Groups E, F, and G.
Switches with a 304 stainless steel body are more corrosion resistant than switches with a brass body and meet NEC Class I, Divisions 1 and 2, Groups A, B, C, and D; and NEC Class II, Divisions 1 and 2, Groups E, F, and G.
For technical drawings and 3-D models, click on a part number.
Set Point | Conduit | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | For Water, gpm | For Air and Inert Gas, scfm | Max. Pressure | Temp. Range, °F | Voltage | Current | Trade Size | Thread Type | Gender | End-to-End Lg. | Each | |
Brass Body | ||||||||||||||
1/2 | NPT | Female | 1.5 | 6.5 | 250 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 1/4" | 00000000 | 0000000 |
3/4 | NPT | Female | 2 | 10 | 250 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 3/8" | 00000000 | 000000 |
1 | NPT | Female | 3 | 14 | 250 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 1/2" | 00000000 | 000000 |
1 1/4 | NPT | Female | 4 | 21 | 250 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 5/8" | 00000000 | 000000 |
1 1/2 | NPT | Female | 6 | 33 | 250 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 7/8" | 00000000 | 000000 |
2 | NPT | Female | 10 | 43 | 250 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 3" | 00000000 | 000000 |
304 Stainless Steel Body | ||||||||||||||
1/2 | NPT | Female | 1.5 | 6.5 | 2000 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 1/4" | 00000000 | 000000 |
3/4 | NPT | Female | 2 | 10 | 2000 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 5/8" | 00000000 | 000000 |
1 | NPT | Female | 3 | 14 | 2000 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 3" | 00000000 | 000000 |
2 | NPT | Female | 10 | 43 | 2000 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 4 3/4" | 00000000 | 00000000 |
Adjustable Hazardous Location Flow Switches for Water, Air, and Inert Gas

For applications with a variable flow rate in environments with flammable gases and combustible dust, these UL-listed switches have an adjustment screw to alter the set point. They activate or deactivate equipment when the flow rate reaches your set point. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
Switch with a brass body meets NEC Class I, Divisions 1 and 2, Groups B, C, and D; and NEC Class II, Divisions 1 and 2, Groups E, F, and G.
Switch with a 304 stainless steel body is more corrosion resistant than the switch with a brass body. It meets NEC Class I, Divisions 1 and 2, Groups A, B, C, and D; and NEC Class II, Divisions 1 and 2, Groups E, F, and G.
For technical drawings and 3-D models, click on a part number.
Set Point | Conduit | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | For Water, gpm | For Air and Inert Gas, scfm | Max. Pressure | Temp. Range, °F | Voltage | Current | Trade Size | Thread Type | Gender | End-to-End Lg. | Each | |
Brass Body | ||||||||||||||
1/2 | NPT | Female | 0.04 to 0.75 | 0.18 to 2.7 | 1450 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 3 5/8" | 00000000 | 0000000 |
304 Stainless Steel Body | ||||||||||||||
1/2 | NPT | Female | 0.04 to 0.75 | 0.18 to 2.7 | 1450 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 3 5/8" | 00000000 | 000000 |
Compact Flow Switches for Oil
The low-profile metal body is designed for use in oil pipelines with limited clearance. These switches activate or deactivate equipment when the flow rate reaches your set point.
SPST-NO switches turn one circuit from “off” to “on” (normally open).
SPDT switches can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
Switches with a 316 stainless steel body are more corrosion resistant than switches with a brass body.
For technical drawings and 3-D models, click on a part number.

Pipe Size | Thread Type | Gender | Body Material | Max. Pressure | Temp. Range, °F | Voltage | Current | End-to-End Lg. | Choose a Set Point, gpm | Each | |
3/8 | NPT | Male | Brass | 1500 psi @ 70° F | -20° to 275° | 120V AC 240V AC | 0.2 A @ 120 V AC | 3 7/16" | 000000 | 0000000 | |
3/8 | NPT | Male | 316 Stainless Steel | 1500 psi @ 70° F | -20° to 275° | 120V AC 240V AC | 0.2 A @ 120 V AC | 3 7/16" | 000000 | 000000 | |
1/2 | NPT | Male | Brass | 1500 psi @ 70° F | -20° to 275° | 120V AC 240V AC | 0.2 A @ 120 V AC | 4" | 000000 | 000000 |

Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Body Material | Max. Pressure | Temp. Range, °F | Voltage | Current | Trade Size | Thread Type | Gender | Port-to-Port Lg. | Choose a Set Point, gpm | Each | |
1/4 | NPT | Female | Brass | 1000 psi @ 70° F | -20° to 225° | 120V AC 240V AC | 0.2 A @ 120 V AC | 1/2 | NPT | Female | 2 1/16" | 000000 | 0000000 | |
1/4 | NPT | Female | Brass | 1000 psi @ 70° F | -20° to 225° | 120V AC 240V AC | 0.2 A @ 120 V AC | 1/2 | NPT | Female | 2 1/16" | 000000 | 000000 |
Compact Flow Switches for Water
These switches have a low-profile design to fit in water pipelines with limited clearance. They activate or deactivate equipment when the flow rate reaches your set point.
SPST-NO switches turn one circuit from “off” to “on” (normally open).
SPDT switches can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
For technical drawings and 3-D models, click on a part number.


Pipe Size | Thread Type | Gender | Body Material | Max. Pressure | Temp. Range, °F | Voltage | Current | End-to-End Lg. | Choose a Set Point, gpm | Each | |
SPST-NO | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/4 | NPT | Female | Polypropylene Plastic | 200 psi @ 70° F | 33° to 194° | 120V AC/ 240V AC | __ | 4 7/8" | 000000 | 000000 | |
3/8 | NPT | Male | Polypropylene Plastic | 125 psi @ 70° F | 33° to 212° | 120V AC | 0.2 A @ 120 V AC | 4" | 0000000 | 00000 |


Pipe Size | Thread Type | Gender | Body Material | Max. Pressure | Temp. Range, °F | Voltage | Current | Max. Current @ Max. Switching Voltage | Port-to-Port Lg. | Choose a Set Point, gpm | Each | |
SPST-NO | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/4 | NPT | Female | Polypropylene Plastic | 200 psi @ 70° F | 33° to 194° | 120V AC/ 240V AC | __ | 0.5 A @ 300 V AC; 0.7 A @ 350 V DC | 1 7/8" | 000000 | 000000 | |
3/4 | NPT | Female | Polypropylene Plastic | 100 psi @ 70° F | 0° to 210° | 120V AC/ 240V AC | 0.2 A @ 120 V AC | __ | 1 1/2" | 0.5 | 0000000 | 000000 |
SPDT | ||||||||||||
1/4 | NPT | Female | PPS Plastic | 250 psi @ 70° F | 32° to 225° | 120V AC/ 240V AC | 0.2 A @ 120 V AC | __ | 1 7/8" | 0000000 | 000000 |
Adjustable Flow Switches for Water and Oil
An adjustment screw lets you alter the set point to suit your application. These switches activate or deactivate equipment when the flow rate reaches your set point. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
For technical drawings and 3-D models, click on a part number.
Flow Switches for Water and Oil

These switches activate or deactivate equipment when the flow rate reaches your set point. They are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
Switches with a 316 stainless steel body are more corrosion resistant than switches with a bronze body.
For technical drawings and 3-D models, click on a part number.
Conduit | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Max. Pressure | Temp. Range, °F | Voltage | Current | Trade Size | Thread Type | Gender | End-to-End Lg. | Choose a Set Point, gpm | Each | |
Bronze Body | |||||||||||||
1 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 3 1/4" | 0000000 | 0000000 | |
1 1/4 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 4" | 0000000 | 000000 | |
1 1/2 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 4 1/2" | 0000000 | 000000 | |
2 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 5 3/8" | 0000000 | 000000 | |
316 Stainless Steel Body | |||||||||||||
1 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 3 1/4" | 0000000 | 000000 | |
1 1/4 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 4 1/2" | 0000000 | 00000000 | |
1 1/2 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 4 1/2" | 5 | 00000000 | 00000000 |
2 | NPT | Female | 400 psi @ 70° F | -20° to 300° | 120V AC/ 240V AC | 0.17 A @ 120 V AC | 1/2 | NPT | Male | 5 3/8" | 0000000 | 00000000 |
Flow Switches with Indicator for Water

For flow monitoring at a glance, these switches have a plastic window with a rotor indicator that spins when flow is present. They activate or deactivate equipment when the flow rate reaches your set point. All have an adjustment screw for altering the set point to suit your application. Switches are single pole, double throw (SPDT) and can be installed to turn one circuit from "off" to "on" (normally open) or from "on" to "off" (normally closed).
Switches with a polypropylene body are lighter than sights with a metal body.
Switches with a 316 stainless steel body are more corrosion resistant than switches with a brass body.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Type | Gender | Set Point, gpm | Max. Pressure | Temp. Range, °F | Voltage | Current | End-to-End Lg. | Each | |
Polypropylene Plastic Body | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/4 | NPT | Female | 0.1 to 5 | 100 psi @ 70° F | 33° to 180° | 120V AC | 0.3 A @ 120 V AC | 3 1/16" | 0000000 | 0000000 |
1/2 | NPT | Female | 1.5 to 20 | 100 psi @ 70° F | 33° to 180° | 120V AC | 0.3 A @ 120 V AC | 3 1/16" | 0000000 | 000000 |
Brass Body | ||||||||||
1/4 | NPT | Female | 0.1 to 5 | 200 psi @ 70° F | 33° to 212° | 120V AC | 0.3 A @ 120 V AC | 3" | 0000000 | 000000 |
1/2 | NPT | Female | 1.5 to 20 | 200 psi @ 70° F | 33° to 212° | 120V AC | 0.3 A @ 120 V AC | 3" | 0000000 | 000000 |
3/4 | NPT | Female | 5 to 30 | 200 psi @ 70° F | 33° to 212° | 120V AC | 0.3 A @ 120 V AC | 3 15/16" | 0000000 | 000000 |
1 | NPT | Female | 8 to 60 | 200 psi @ 70° F | 33° to 212° | 120V AC | 0.3 A @ 120 V AC | 3 15/16" | 0000000 | 000000 |
316 Stainless Steel Body | ||||||||||
1/2 | NPT | Female | 1.5 to 20 | 200 psi @ 70° F | 33° to 212° | 120V AC | 0.3 A @ 120 V AC | 3" | 0000000 | 000000 |
3/4 | NPT | Female | 5 to 30 | 200 psi @ 70° F | 33° to 212° | 120V AC | 0.3 A @ 120 V AC | 3 15/16" | 0000000 | 000000 |
1 | NPT | Female | 8 to 60 | 200 psi @ 70° F | 33° to 212° | 120V AC | 0.3 A @ 120 V AC | 3 15/16" | 0000000 | 000000 |
Washdown Flow Switches for Water and Oil

For protection from dirt, washdowns, and corrosion, these switches have an enclosure that meets IP66 and NEMA 4X. They activate or deactivate equipment when the flow rate reaches your set point and have an adjustment screw for altering the set point. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Type | Gender | Max. Pressure | Temp. Range, °F | Voltage | Current | Conduit Trade Size | End-to-End Lg. | Choose a Set Point, gpm | Each | |
Bronze Body | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/4 | NPT | Female | 400 psi @ 70° F | -30° to 212° | 120V AC | 0.4 A @ 120 V AC | 1/2 | 3 1/16" | 0000000 | 0000000 | |
1/2 | NPT | Female | 400 psi @ 70° F | -30° to 212° | 120V AC | 0.4 A @ 120 V AC | 1/2 | 3 1/16" | 0000000 | 000000 | |
3/4 | NPT | Female | 400 psi @ 70° F | -30° to 212° | 120V AC | 0.4 A @ 120 V AC | 1/2 | 3 1/16" | 0000000 | 000000 | |
1 | NPT | Female | 400 psi @ 70° F | -30° to 212° | 120V AC | 0.4 A @ 120 V AC | 1/2 | 3 1/16" | 0000000 | 000000 | |
1 1/2 | NPT | Female | 400 psi @ 70° F | -30° to 212° | 120V AC | 0.4 A @ 120 V AC | 1/2 | 3 1/16" | 0000000 | 000000 | |
2 | NPT | Female | 400 psi @ 70° F | -30° to 212° | 120V AC | 0.4 A @ 120 V AC | 1/2 | 3 3/16" | 0000000 | 000000 |
Flow Transmitters for Water

Send flow-rate readings to data recorders, loggers, and displays.
Transmitters with a 316 stainless steel body are more corrosion resistant than transmitters with a brass or polypropylene body.
For technical drawings and 3-D models, click on a part number.
Output | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | End-to-End Lg. | Flow Range, gpm | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Signal Connection | Signal, mA | Current | Wire Lead Lg. | Each | |
Polypropylene Plastic Body | |||||||||||||
Gallons per Minute | |||||||||||||
1/4 NPT Female | 3 1/16" | 0.1 to 5 | ±7% | 100 psi @ 70° F | 33° to 180° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 0000000 |
1/2 NPT Female | 3 1/16" | 1.5 to 20 | ±15% | 100 psi @ 70° F | 33° to 180° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 000000 |
Brass Body | |||||||||||||
Gallons per Minute | |||||||||||||
1/4 NPT Female | 3" | 0.1 to 5 | ±7% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 000000 |
1/2 NPT Female | 3" | 1.5 to 20 | ±15% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 000000 |
1 NPT Female | 3 15/16" | 8 to 60 | ±15% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 000000 |
316 Stainless Steel Body | |||||||||||||
Gallons per Minute | |||||||||||||
1/2 NPT Female | 3" | 1.5 to 20 | ±15% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 000000 |
3/4 NPT Female | 3 15/16" | 5 to 30 | ±15% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 000000 |
1 NPT Female | 3 15/16" | 8 to 60 | ±15% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Horizontal, Vertical | Wire Leads | 70 | 0.008 A @ 24 V DC | 24" | 0000000 | 000000 |
Compact Flow Transmitters for Water
Use these transmitters in areas with limited clearance to send flow-rate readings to data recorders, loggers, and displays. They have a 316 stainless steel body for corrosion resistance in harsh environments.
Optional display meter accepts flowmeter output signals and registers flow rate and total. The display can be manually reset.
For technical drawings and 3-D models, click on a part number.

Output | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Overall Ht. | Dia. | Flow Range, ml/min. | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Signal Connection | Signal | Voltage | Each | |
316 Stainless Steel Body | |||||||||||||
Milliliters per Minute | |||||||||||||
1/8 NPT Female | 2 7/8" | 1 1/2" | 3 to 300 | ±0.5% | 1450 psi @ 70° F | -22° to 176° | Viton® Fluoroelastomer | Horizontal, Vertical | Wire Leads | 3V DC to 25V DC | 4V DC 26V DC | 0000000 | 000000000 |
1/8 NPT Female | 2 7/8" | 1 15/16" | 10 to 1,000 | ±0.5% | 1450 psi @ 70° F | -22° to 176° | Viton® Fluoroelastomer | Horizontal, Vertical | Wire Leads | 3V DC to 25V DC | 4V DC 26V DC | 0000000 | 00000000 |

Overall | ||||||||
---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Wire Connection Type | Reset Type | Environmental Rating | Specifications Met | Each | |
0.945" | 1.89" | 2.729" | Screw Terminals | Button | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 0000000 |
Flow Transmitters for Air

Calibrated for compressed air, these transmitters send flow-rate readings to data recorders, loggers, and displays. They have compression tube connections that bite down on hard metal and plastic tubing for a secure seal. The digital display shows the flow rate, so these transmitters can also be used as flowmeters. Fittings are 316 stainless steel for corrosion resistance in harsh environments.
For technical drawings and 3-D models, click on a part number.
Output | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tube Connections | End-to-End Lg. | Flow Range | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Signal Connection | Signal | Voltage | Plug Type | Each | |
ABS Plastic Body with 316 Stainless Steel | |||||||||||||
Cubic Centimeters per Minute | |||||||||||||
Male Compression for 1/8" Tube OD | 4 7/8" | 1.08 to 54 cc/min. | ±3% | 150 psi @ 70° F | 32° to 122° | Elastomer Rubber | Horizontal | RS-232 Port | 4 to 20 mA | 120V AC 240V AC | Two Prong | 0000000 | 000000000 |
Male Compression for 1/8" Tube OD | 4 7/8" | 4 to 200 cc/min. | ±3% | 150 psi @ 70° F | 32° to 122° | Elastomer Rubber | Horizontal | RS-232 Port | 4 to 20 mA | 120V AC 240V AC | Two Prong | 0000000 | 00000000 |
Male Compression for 1/8" Tube OD | 4 7/8" | 10 to 500 cc/min. | ±3% | 150 psi @ 70° F | 32° to 122° | Elastomer Rubber | Horizontal | RS-232 Port | 4 to 20 mA | 120V AC 240V AC | Two Prong | 0000000 | 00000000 |
Liters per Minute | |||||||||||||
Male Compression for 1/8" Tube OD | 4 7/8" | 0.02 to 1 lpm | ±3% | 150 psi @ 70° F | 32° to 122° | Elastomer Rubber | Horizontal | RS-232 Port | 4 to 20 mA | 120V AC 240V AC | Two Prong | 0000000 | 00000000 |
Male Compression for 1/8" Tube OD | 4 7/8" | 0.1 to 5 lpm | ±3% | 150 psi @ 70° F | 32° to 122° | Elastomer Rubber | Horizontal | RS-232 Port | 4 to 20 mA | 120V AC 240V AC | Two Prong | 0000000 | 00000000 |