    56 Products

    Vertical-Mount Float Switches for Fuels and Oils

    Image of Product. Float Switch. Front orientation. Contains Annotated. Vertical-Mount Float Switches for Fuels and Oils.
    Image of Product. Float Switch with Splash Guard. Front orientation. Contains Annotated. Vertical-Mount Float Switches for Fuels and Oils, Splash Guard.

    Float Switch

    Float Switch with

    Splash Guard

    Mount these switches from outside the tank through a threaded connection at the top or bottom of your tank. They activate process equipment such as pumps or motors when the diesel fuel, hydraulic fluid, or oil level in your tank reaches the float.
    316 Stainless Steel Float—Choose switches with a stainless steel float for durability in harsh conditions.
    Splash Guard—Switches with splash guard minimize false switch activation caused by splashing liquid.
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Mounting
    Location
    Float
    Ht.
    Overall
    Dia.
    Electrical
    Connection
    Each
    120V AC/240V AC Input Voltage
     
    Buna-N Float
    1/8
    NPT
    Male0.45150 psi @ 70° F35 to 2501 9/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACTop, Bottom1"1"Wire Leads48095K11000000
    1/8
    NPT
    Male0.55150 psi @ 70° F35 to 1451 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACTop, Bottom1"1"Wire Leads48095K6100000
    1/4
    NPT
    Male0.55150 psi @ 70° F35 to 1452 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2"1 1/4"Wire Leads48095K8100000
     
    Buna-N Float with Splash Guard
    1/8
    NPT
    Male0.55150 psi @ 70° F35 to 1451 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACTop, Bottom1"1 1/2"Wire Leads48095K6200000
    1/4
    NPT
    Male0.55150 psi @ 70° F35 to 1452 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2"2"Wire Leads48095K8200000
     
    316 Stainless Steel Float
    1/8
    NPT
    Male0.7300 psi @ 70° F35 to 3002 1/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom1 3/16"1 1/8"Wire Leads4646K82000000
     

    Vertical-Mount Float Switches for Water

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Float Switches for Water, Buna-N Float.
    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Float Switches for Water, Polypropylene Float.
    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Float Switches for Water, CPVC Float.
    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Float Switches for Water, 316 Stainless Steel Float.

    Buna-N Float

    Polypropylene

    Float

    CPVC Float

    316 Stainless Steel

    Float

    Mount these switches from outside the tank through a threaded connection at the top or bottom of your tank. They activate process equipment such as pumps or motors when the water level in your tank reaches the float. Choose switches with a stainless steel float for durability in harsh conditions.
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Mounting
    Location
    Float
    Ht.
    Overall
    Dia.
    Electrical
    Connection
    Each
    120V AC/240V AC Input Voltage
     
    Buna-N Float
    1/8
    NPT
    Male0.4550 psi @ 70° F35 to 1501 7/8"1 On
    SPST-NC
    0.17 amp @ 120V ACTop, Bottom1 1/16"1 7/8"Wire Leads48095K41000000
     
    Polypropylene Float
    1/8
    NPT
    Male0.650 psi @ 70° F35 to 2251 9/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACTop, Bottom1"1"Wire Leads50195K1100000
    1/8
    NPT
    Male0.9150 psi @ 70° F35 to 1501 9/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACTop, Bottom1"1"Wire Leads50195K7500000
    1/8
    NPT
    Male0.9150 psi @ 70° F35 to 1501 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACTop, Bottom1"3/4"Wire Leads50195K6500000
     
    CPVC Float
    1/4
    NPT
    Male0.8515 psi @ 70° F35 to 1802 15/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACTop, Bottom1 13/16"1 1/2"Wire Leads5127K21000000
     
    316 Stainless Steel Float
    1/2
    NPT
    Male0.35300 psi @ 70° F35 to 3004 13/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACTop, Bottom3 1/2"3 1/2"Wire Leads4646K37000000
     

    Dual-Level Vertical-Mount Float Switches for Water

    Image of Product. Front orientation. Contains Annotated. Float Switches. Dual-Level Vertical-Mount Float Switches for Water.
    Empty and fill your tank with a single device—these dual-level switches include two float switches that actuate at different levels. The stem can be cut to length. Mount through a threaded connection at the top of your tank.
    Overall
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Float
    Ht.
    Ht.
    Dia.
    Electrical
    Connection
    Includes
    Each
    120V AC/240V AC Input Voltage
     
    Polypropylene Float
    2
    NPT
    Male0.85100 psi @ 70° F35 to 22036"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop2"38 5/8"1 1/2"Wire LeadsTwo Switches, Fittings5267K440000000
     

    Vertical-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Hazardous Location Float Switches for Fuels and Oils.
    For use in locations with flammable gases and combustible dust, these switches are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    316 Stainless Steel Body and Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K97000000000
     

    Through-Wall Vertical-Mount Float Switches for Water

    Image of Product. Front orientation. Contains Annotated. Float Switches. Through-Wall Vertical-Mount Float Switches for Water.
    Install these switches into an unthreaded hole at the top or bottom of your tank and secure with a nut from inside the tank. They activate process equipment such as pumps or motors when the water level in your tank reaches the float.
    For Hole
    Dia.
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Mounting Location
    Float
    Ht.
    Overall
    Dia.
    Electrical
    Connection
    Includes
    Each
    120V AC/240V AC Input Voltage
     
    Polypropylene Float
    3/8"0.9150 psi @ 70° F35 to 1501 9/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACThrough Wall, Top, Bottom1"1"Wire LeadsMounting Nut50195K76000000
     

    Vertical-Mount Compressed-Air Float Switches for Fuels and Oils

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Compressed-Air Float Switches for Fuels and Oils.
    Mount these switches through the top of your tank. They actuate with a compressed air valve instead of an electrical signal. The air valve opens when diesel fuel, hydraulic fluid, oil, or water moves the float.
    Pipe
    Air
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Mounting
    Location
    Air Inlet
    Pressure, psi
    Overall
    Lg.
    No. of
    Ports
    For Tube
    ID
    Gender
    Each
     
    303 Stainless Steel Body and 304 Stainless Steel Float
    1
    NPT
    Male0.5200 psi @ 70° F35 to 1403 1/2"Top30 to 1007 5/8"33/32"Male3792K420000000
     

    Paddle Level Switches for Dry Materials

    Image of Product. Front orientation. Contains Annotated. Paddle Level Switches. Vertical Mount.

    Vertical Mount

    Monitor the level of dry material in surge bins, tanks, and silos to avoid overspills and outages. With a long paddle, these switches extend farther into large storage containers to detect material levels where other types of switches can’t reach. You can even adjust the paddle's sensitivity to materials of different sizes and shapes, such as powders, plastic pellets, and wood chips. Install multiple switches on the same container to monitor levels at various points. They are rated NEMA 4X and IP66 for protection from corrosion and washdowns.
    Vertical Mount—Mount to the roof of containers to indicate high levels when loading material. For domed roofs, you can extend these switches farther down by connecting the paddle to your desired length of 1/8 NPT Schedule 40 pipe. The paddle rotates freely until material rises to its level and stops it, triggering a conveyor, pump, or other piece of equipment to prevent overfilling.
    With Alarm—Switches with an alarm alert you to potential malfunctions before they occur. They continuously perform self-diagnostics to detect everything from motor failure to seized bearings. When they detect an error, an LED light flashes in a corresponding code, so maintenance workers will immediately know which problem they need to fix.
    Paddle
    Switch
    Insertion
    Dp.
    Material Wt. Cap.
    Range, lb/ft³
    Max. Pressure
    @ Temp.
    Speed,
    rpm
    Lg.
    Wd.
    Material
    Starting
    Position
    Designation
    Current @
    Voltage
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Vertical Mount
     
    Without Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    20 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K520000000
     
    With Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    8 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K36000000
     
    Replacement Electric Motors for 20 amp @ 120V AC Paddle Level Switches

    Vertical-Mount Float Switches for Food and Beverage

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Float Switches for Food and Beverage, Style A.
    Image of Product. Style B. Front orientation. Contains Annotated. Style B. Vertical-Mount Float Switches for Food and Beverage.
    Image of Product. Style C. Front orientation. Contains Annotated. Style C. Vertical-Mount Float Switches for Food and Beverage.

    Style A

    Style B

    Style C

    Mount these switches into a threaded connection at the top or bottom of your tank. Often used in food-processing applications, they meet NSF/ANSI Standard 169.
    Switches
    Replacement
    Floats
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Mounting
    Location
    Float
    Ht.
    Overall
    Dia.
    Electrical
    Connection
    Certification
    Each
    Each
    120V AC/240V AC Input Voltage
     
    Polypropylene Float
    A1/8
    NPT
    Male0.9100 psi @ 70° F35 to 2201 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACTop, Bottom1"1"Wire LeadsUL Recognized Component, CSA Certified
    50195K9300000050195K96000000
    A1/4
    NPT
    Male0.87100 psi @ 70° F35 to 2202 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2"1 1/2"Wire LeadsUL Recognized Component, CSA Certified
    50195K130000050195K9700000
     
    PVDF Float
    A1/8
    NPT
    Male0.8515 psi @ 70° F35 to 2201 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACTop, Bottom1"1"Wire LeadsUL Recognized Component, CSA Certified
    44785K130000044785K1800000
     
    316 Stainless Steel Float
    B1/8
    NPT
    Male0.8300 psi @ 70° F35 to 3901 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACTop, Bottom1 3/16"1 1/8"Wire LeadsUL Recognized Component, CSA Certified
    4646K83000004646K8900000
    B1/4
    NPT
    Male0.65200 psi @ 70° F35 to 3902 15/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2 1/8"2 1/8"Wire LeadsUL Recognized Component, CSA Certified
    4646K85000004646K8700000
    B1/4
    NPT
    Male0.65200 psi @ 70° F35 to 4802 15/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2 1/8"2 1/8"Wire LeadsUL Recognized Component, CSA Certified
    4646K15000004646K8700000
    C1/4
    NPT
    Male0.8500 psi @ 70° F35 to 3902 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    1 amp @ 120V ACTop, Bottom2 1/16"2 1/16"Wire Leads4646K530000004646K8700000
    C1/4
    NPT
    Male0.8750 psi @ 70° F35 to 3002 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACTop, Bottom2 1/16"2 1/16"Wire LeadsUL Recognized Component, CSA Certified
    4646K230000004646K8700000
     
    Replacement Float Clips

    Dual-Level Vertical-Mount Float Switches for Fuels and Oils

    Image of Product. Front orientation. Contains Annotated. Float Switches. Dual-Level Vertical-Mount Float Switches for Fuels and Oils.
    Empty and fill your tank with a single device—these dual-level switches include two float switches that actuate at different levels. The stem can be cut to length. Mount through a threaded connection at the top of your tank.
    Overall
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Mounting
    Location
    Float
    Ht.
    Ht.
    Dia.
    Electrical
    Connection
    Each
    120V AC/240V AC Input Voltage
     
    Buna-N Float
    2
    NPT
    Male0.55150 psi @ 70° F35 to 18033 1/2"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACTop1 11/16"35"1 7/8"Wire Leads5267K840000000
     
    316 Stainless Steel Float
    2
    NPT
    Male0.75750 psi @ 70° F35 to 27534"1 Off/1 On
    SPST-NO
    SPST-NC
    0.17 amp @ 120V ACTop2"35 1/2"2 1/16"Wire Leads5267K8800000000
     

    Hazardous Location Float Switches for Water

    Image of Product. Front orientation. Contains Annotated. Float Switches. Hazardous Location Float Switches for Water.
    For use in locations with flammable gases and combustible dust, these switch are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body and 316 Stainless Steel Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2755 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N130000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2757 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N16000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K96000000
    2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N11000000
     

    Vertical-Mount Float Switches for Chemicals

    Image of Product. Float Switch. Front orientation. Contains Annotated. Vertical-Mount Float Switches for Chemicals.
    Image of Product. Float Switch with Splash Guard. Front orientation. Contains Annotated. Vertical-Mount Float Switches for Chemicals, Splash Guard.

    Float Switch

    Float Switch with

    Splash Guard

    Mount these switches from outside the tank through a threaded connection at the top or bottom of your tank. They activate process equipment such as pumps or motors when the chemical level in your tank reaches the float.
    316 Stainless Steel Float—Choose switches with a 316 stainless steel float for durability in harsh conditions.
    Splash Guard—Switches with splash guard minimize false switch activation caused by splashing liquid.
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Float
    Ht.
    Overall
    Dia.
    Electrical
    Connection
    Each
    120V AC/240V AC Input Voltage
     
    Polypropylene Float
    1/4
    NPT
    Male0.85100 psi @ 70° F35 to 2202 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2"1 1/2"Wire Leads50195K85000000
    1/4
    NPT
    Male0.85100 psi @ 70° F35 to 2202 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    1 amp @ 120V ACTop, Bottom2"1 1/2"Wire Leads50195K6200000
     
    Polypropylene Float with Splash Guard
    1/8
    NPT
    Male0.9100 psi @ 70° F35 to 2201 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.3 amp @ 120V ACTop, Bottom1"1 1/2"Wire Leads50195K9400000
    1/4
    NPT
    Male0.85100 psi @ 70° F35 to 2202 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2"2"Wire Leads50195K8400000
     
    PVDF Float with Splash Guard
    1/8
    NPT
    Male0.9515 psi @ 70° F35 to 2201 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.3 amp @ 120V ACTop, Bottom1"1 1/2"Wire Leads44785K1600000
     
    316 Stainless Steel Float with Splash Guard
    1/4
    NPT
    Male0.65200 psi @ 70° F35 to 4802 15/16"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2 1/8"2 3/8"Wire Leads4646K16000000
     

    Through-Wall Vertical-Mount Float Switches for Chemicals

    Image of Product. Front orientation. Float Switches. Through-Wall Vertical-Mount Float Switches for Chemicals.
    Install these switches into an unthreaded hole at the top or bottom of your tank and secure with a nut from inside the tank. They activate process equipment such as pumps or motors when the chemical level in your tank reaches the float.
    For Hole
    Dia.
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Mounting Location
    Float
    Ht.
    Overall
    Dia.
    Electrical
    Connection
    Includes
    Each
    120V AC Input Voltage
     
    Polypropylene Float
    3/8"0.750 psi @ 70° F35 to 2201 1/4"1 Off
    SPST-NO
    0.12 amp @ 120V ACThrough Wall, Top, Bottom5/8"9/16"Wire LeadsMounting Nut50195K74000000
    3/8"0.750 psi @ 70° F35 to 2201 1/4"1 On
    SPST-NC
    0.12 amp @ 120V ACThrough Wall, Top, Bottom5/8"9/16"Wire LeadsMounting Nut50195K7300000
     

    Vertical-Mount Float Switches with Brackets for Chemicals

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Float Switches with Brackets for Chemicals.
    Use the included bracket to mount these switches to the inside of your tank. They activate process equipment such as pumps or motors when the chemical level in your tank reaches the float. A splash guard minimizes false switch activation caused by splashing liquid.
    316 Stainless Steel Float—Choose switches with a 316 stainless steel float for durability in harsh conditions.
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Float
    Ht.
    Overall
    Dia.
    Each
    120V AC/240V AC Input Voltage
     
    Polypropylene Float with Splash Guard
    0.85100 psi @ 70° F35 to 2203 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2"2 1/2"4666K730000000
     
    316 Stainless Steel Float with Splash Guard
    0.6585 psi @ 70° F35 to 2303 7/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.5 amp @ 120V ACTop, Bottom2"2 1/2"4666K74000000
     

    Vertical-Mount Float Switches with Bracket for Fuels and Oils

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Float Switches with Bracket for Fuels and Oils.
    Use the included bracket to mount these switches to the inside of your tank. They activate process equipment such as pumps or motors when the diesel fuel, hydraulic fluid, or oil level in your tank reaches the float.
    Mounting
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Mounting
    Location
    Float
    Ht.
    Overall
    Dia.
    Electrical
    Connection
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    120V AC/240V AC Input Voltage
     
    Buna-N Float
    0.55150 psi @ 70° F35 to 1403 3/16"1 Off
    SPST-NO
    0.17 amp @ 120V ACTop, Bottom1 9/16"2 5/8"Wire LeadsNo29/32"4879K210000000
    0.55150 psi @ 70° F35 to 1403 3/16"1 Off
    SPST-NO
    0.4 amp @ 120V ACTop, Bottom1 9/16"2 5/8"Wire LeadsNo29/32"4879K25000000
    0.55150 psi @ 70° F35 to 1403 3/16"1 On
    SPST-NC
    0.17 amp @ 120V ACTop, Bottom1 9/16"2 5/8"Wire LeadsNo29/32"4879K23000000
    0.55150 psi @ 70° F35 to 1403 3/16"1 On
    SPST-NC
    0.4 amp @ 120V ACTop, Bottom1 9/16"2 5/8"Wire LeadsNo29/32"4879K27000000
     
    back to top