Choosing an Electrical Switch
More
Toggle Switches

Switches with an on-on or on-(on) position designation alternate power between sets of terminals.
To view switch wiring diagrams, select a part number and click Product Detail.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | For Max. Panel Thick. | Mounting Hardware Included | Choose a Wire Connection Type | Each | |
2 Position with Rounded Toggle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For 1/2" Panel Cutout Dia. | ||||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 15 A @ 125 V AC/28 V DC | 28V DC 250V AC | 0.13" | Yes | 00000000 | 000000 |
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | For Max. Panel Thick. | Mounting Hardware Included | Choose a Wire Connection Type | Each | |
3 Position with Rounded Toggle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For 1/2" Panel Cutout Dia. | ||||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 15 A @ 125 V AC/28 V DC | 28V DC 250V AC | 0.13" | Yes | 00000000 | 000000 |
Miniature Toggle Switches

Maximize the space in a panel—these switches are half the size of most toggle switches.
Switches with an on-on or on-(on) position designation alternate power between sets of terminals.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | Dp. Behind Panel | Mounting Hardware Included | Wire Connection Type | Each | |
2 Position with Rounded Toggle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For 1/4" Panel Cutout Dia. | ||||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 6 A @ 125 V AC, 4 A @ 30 V DC | 30V DC 250V AC | 0.66" | Yes | Solder Lugs | 0000000 | 000000 |
High-Current Toggle Switches

Able to withstand high currents, these switches are often used with motors and pumps.
Switches with an on-on position designation alternate power between sets of terminals.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | Dp. Behind Panel | Mounting Hardware Included | Each | |
2 Position with Quick-Disconnect Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 20 A @ 125 V AC, 20 A @ 30 V DC | 30V DC 250V AC | 1.31" | Yes | 0000000 | 000000 |
2 Position with Screw Terminals | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-On | 30 A @ 125 V AC/30 V DC | 30V DC 250V AC | 1.34" | Yes | 0000000 | 00000 |
3 Position with Quick-Disconnect Terminals | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 20 A @ 125 V AC, 20 A @ 30 V DC | 30V DC 250V AC | 1.31" | Yes | 0000000 | 00000 |
3 Position with Screw Terminals | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 30 A @ 125 V AC/30 V DC | 30V DC 250V AC | 1.34" | Yes | 0000000 | 00000 |
3 Position with Solder Lugs | |||||||||||
For 1/2" Panel Cutout Dia. | |||||||||||
3 | 3 Off (Normally Open) or 3 On (Normally Closed) | Stays Switched (Maintained) | 9 | 3PDT | On-Off-On | 20 A @ 125 V AC, 20 A @ 30 V DC | 30V DC 250V AC | 1.08" | Yes | 0000000 | 00000 |
Rotary Switches

Control multiple devices with one switch. Turn the shaft to change switch positions. Each position closes a set of contacts per circuit, so you can select between multiple devices on one or more circuits.
For technical drawings and 3-D models, click on a part number.
Shaft | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Action | No. of Positions | No. of Terminals | Dp. Behind Panel | O'all Dia. | Lg. | Dia. | Each | ||
Nickel-Plated Brass with Black Plastic Knob | ||||||||||
With Solder Pin Terminals for 1/4" Panel Cutout Dia. | ||||||||||
1 | Stays Switched (Maintained) | 8 | 9 | 1 1/16" | 9/16" | 13/16" | 1/8" | 2 A @ 125 V AC, 1 A @ 30 V DC | 0000000 | 000000 |
DIN-Rail Mount Motor Voltage Monitors

Mount these monitors to 35 mm DIN rail. They protect electric motors from phase loss, phase reversal, overvoltage, undervoltage, and voltage imbalance. Also known as voltage-monitoring relays, they cut power to a motor when a fault occurs.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Trip Time, sec. | Reset Type | Current, A | Voltage | Horsepower @ Voltage | Ht. | Wd. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
Three Phase | |||||||||||||
200-480V AC | 9 | 5 | 2%-10% | 1-30 | Automatic | 10 | 240V AC | 1/3 hp @ 240 V AC | 3" | 2" | UL Listed, C-UL Listed | 0000000 | 0000000 |
Latching Relays


A single, momentary input voltage switches these relays and latches them in position, so they don't require a constant input voltage to stay switched. A second momentary voltage will release the latch.
Relay sockets (sold separately) mount to 35 mm DIN rail.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC/28V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Specifications Met | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
9 | 24V AC | 70 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 000000 | 0000000 | 000000 |
9 | 120V AC | 14 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
9 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |
9 | 24V DC | 50 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | UL Recognized Component CSA Certified | 0000000 | 00000 | 0000000 | 00000 |