Choosing an Electrical Switch
More
Vibration-Resistant Plastic 22 mm Emergency
Stop Panel-Mount Push-Button Switches
A single-piece construction prevents the contact block from separating from the actuator in high-vibration applications. These switches immediately cut power with a single push. All meet EN 60947-5-5 for compliance with European machine directives for emergency stop applications. They have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. These switches meet American, Canadian, European, and other global safety requirements. They’re rated NEMA 4X, NEMA 13, and IP65 for protection from corrosion, washdowns, and oil/coolant spraying.
Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
When-on illuminated switches light up when you push the button, so you can tell if the power has been cut.
Continuously illuminated switches stay lit once installed for high visibility in dark areas.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Environmental Rating | Each | |
Turn Reset with Screw Terminals | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | __ | 1 9/16" | 1 7/8" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 000000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | __ | 1 9/16" | 1 7/8" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
Turn Reset with Screw Terminals—Illuminated (When On) | ||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
Turn Reset with Screw Terminals—Illuminated (Continuous) | ||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
Emergency Stop Label—Yellow Plastic | 0000000 | Each | 00000 |
Easy-Grip Pendant Switches
With a slim shape, these switches fit comfortably in your hand. Use them with mobile machinery such as cranes, hoists, and trolleys.
Two-speed switches have staged contacts. When you push the button, it will first actuate the slow speed. Continue to push for the additional speed to be actuated.
Switches with mechanical interlock prevent both buttons from operating simultaneously.
NEMA 4X rated switches protect against corrosion.
For technical drawings and 3-D models, click on a part number.
Style | No. of Buttons | No. of Circuits Controlled per Actuator | Switch Starting Position | Switch Action | No. of Terminals per Actuator | Switching Current @ Voltage | Max. Voltage | Message (Actuator Color—Industry Designation) | Housing Material | Each | |
2 Speed with Screw Terminals and Mechanical Interlock | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
NEMA 4X and IP55 | |||||||||||
D | 2 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 3 | 3 A @ 120 V AC; 1.1 A @ 24 V DC | 120V AC 125V DC | Up (Black—SPST-NO), Down (Black—SPST-NO) | Yellow Plastic | 0000000 | 0000000 |
Cable-Pull Emergency Stop Switches
Immediately cut power by pulling a cable. All have positive force, snap open contacts that will open the circuit when actuated even if a spring fails or the contacts stick. Cables must be held in position under tension.
Two-direction switches can be used with tension springs (sold separately) to open contacts and stop machinery if the cable breaks.
Accessory kits (sold separately) simplify the installation of a new switch.
For technical drawings and 3-D models, click on a part number.
Switches | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting | Accessory Kits | |||||||||||||||
For Max. Cable Lg., ft. | No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Actuation Force, lbs. | Conduit Trade Size | Fasteners Included | No. of Holes | Hole Dia. | Each | Includes | Each | ||
With Screw Terminals | ||||||||||||||||
2 Direction (IP67) | ||||||||||||||||
165 | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 4 | DPST-1NO/1NC | 1.1 A @ 120 V AC | 240V AC | 5 | 3/4 | No | 2 | 5/16" | 00000000 | 0000000 | Cable, Clamps, Eyebolts, Tension Screws, Tension Springs | 00000000 | 0000000 |