Clear All
System of Measurement System of Measurement |
---|
|
Switching Current Switching Current | Show |
---|
|
Switching Current Switching Current | Hide |
---|
Set Time Set Time |
---|
|
Power Power |
---|
|
Timing Adjustment Style Timing Adjustment Style |
---|
![]() | Knob |
Switch Starting Position Switch Starting Position |
---|
|
Auxiliary Contact Switch Starting Position Auxiliary ContactSwitch Starting Position |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | Screw Terminals |
With Override With Override |
---|
|
Specifications Met Specifications Met |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Number of Terminals Number of Terminals |
---|
|
For Outlet Box Type For Outlet Box Type |
---|
|
Knob Color Knob Color |
---|
![]() | Black |
Switch Type Switch Type |
---|
|
About Relays
More
High-Current Wall-Mount Timer Switches

Control equipment with high currents such as air conditioners, heaters, and ventilating equipment. They automatically turn electrical equipment on or off after a set interval of time.
Switches with override can bypass the automatic shut-off.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Includes | Wire Connection Type | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Without Override | |||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Replacement Knob | 0000000 | Each | 00000 |
High-Current Relays

4 Circuits
Use these relays with large motors and lighting systems. Also known as IEC contactors, they are built to International Electrotechnical Commission (IEC) dimensional standards. All have recessed terminals to prevent contact with live connections. Mount to 35 mm DIN rail.
Auxiliary contacts allow you to add a signaling device or control another relay. Add one front-mount contact per relay or two side-mount contacts per relay.
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Specifications Met | Each | |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
With 1 Auxiliary Contact—1 Off (Normally Open) | ||||||||||||
12 | 24V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 000000 |
12 | 120V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 24V DC | 5.4W | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed | 00000000 | 000000 |
With 1 Auxiliary Contact—1 On (Normally Closed) | ||||||||||||
12 | 24V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 24V DC | 5.4W | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed | 00000000 | 000000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11A | 28A | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |