Actuator Style Actuator Style |
|---|
![]() | Rocker |
Illumination Illumination |
|---|
|
Wire Connection Type Wire Connection Type |
|---|
![]() | |
| Quick- Disconnect Terminals | Screw Terminals |
| Wire Leads |
System of Measurement System of Measurement |
|---|
|
For Panel Cutout Width For Panel Cutout Width |
|---|
|
Position Designation Position Designation |
|---|
|
Bulb Voltage Bulb Voltage |
|---|
|
Maximum Voltage Maximum Voltage |
|---|
|
Quick-Disconnect Tab Width Quick-Disconnect Tab Width |
|---|
|
For Panel Cutout Height For Panel Cutout Height |
|---|
|
Number of Positions Number of Positions |
|---|
|
Switch Action Switch Action |
|---|
|
Mount Type Mount Type |
|---|
|
Switching Current Switching Current | Show |
|---|
|
Switching Current Switching Current | Hide |
|---|
For Maximum Panel Thickness For Maximum Panel Thickness |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
Choosing an Electrical Switch
More
About Relays
More
Miniature Rocker Switches


Maximize space in a panel—these switches are smaller than most standard rocker switches.
Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
For technical drawings and 3-D models, click on a part number.
Wire Leads | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | No. of | Lg. | Quick-Disconnect Tab Wd. | Bulb Type | Choose a Color | Each | |
2 Position with Quick-Disconnect Terminals—Illuminated | |||||||||||||||
For 3/4" Ht.×1/2" Wd. Panel Cutout | |||||||||||||||
| 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | __ | __ | 0.187" | Neon | 0000000 | 00000 | |
2 Position with Wire Leads—Illuminated | |||||||||||||||
For 3/4" Ht.×1/2" Wd. Panel Cutout | |||||||||||||||
| 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | 4 | 12" | __ | Neon | Green | 00000000 | 00000 |
| 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | 4 | 12" | __ | Neon | Red | 00000000 | 00000 |
| 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | 4 | 12" | __ | Neon | Yellow | 00000000 | 00000 |
High-Current Relays

Use these relays with large motors and lighting systems. Also known as IEC contactors, they are built to International Electrotechnical Commission (IEC) dimensional standards. All have recessed terminals to prevent contact with live connections. Mount to 35 mm DIN rail.
Auxiliary contacts allow you to add a signaling device or control another relay. Add one front-mount contact per relay or two side-mount contacts per relay.
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Specifications Met | Each | |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
| 12 | 24V AC | 6.5VA | 9A | 25A | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 000000 |
| 12 | 120V AC | 6.5VA | 9A | 25A | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
| 12 | 240V AC | 6.5VA | 9A | 25A | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | UL Listed C-UL Listed | 000000000 | 00000 |
| 12 | 24V DC | 5.4W | 9A | 25A | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | UL Listed C-UL Listed | 00000000 | 000000 |



























