Choosing an Electrical Switch
More
Vibration-Resistant Plastic 22 mm Emergency
Stop Panel-Mount Push-Button Switches
A single-piece construction prevents the contact block from separating from the actuator in high-vibration applications. These switches immediately cut power with a single push. All meet EN 60947-5-5 for compliance with European machine directives for emergency stop applications. They have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. These switches meet American, Canadian, European, and other global safety requirements. They’re rated NEMA 4X, NEMA 13, and IP65 for protection from corrosion, washdowns, and oil/coolant spraying.
Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
When-on illuminated switches light up when you push the button, so you can tell if the power has been cut.
Continuously illuminated switches stay lit once installed for high visibility in dark areas.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Environmental Rating | Each | |
Turn Reset with Screw Terminals | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | __ | 1 9/16" | 1 7/8" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 000000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | __ | 1 9/16" | 1 7/8" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
Turn Reset with Screw Terminals—Illuminated (When On) | ||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
Turn Reset with Screw Terminals—Illuminated (Continuous) | ||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 24V AC 24V DC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 120V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 3 A @ 220 V AC, 1.1 A @ 110 V DC | 600V AC 600V DC | 240V AC | 1 9/16" | 2 1/2" | 1 | NEMA 4X, NEMA 13, IP65 | 0000000 | 00000 |
Emergency Stop Label—Yellow Plastic | 0000000 | Each | 00000 |
Solid State Circular-Pin Relays
With no moving parts, these solid state relays are faster switching, quieter, and longer lasting than mechanical switches. The circular-pin terminals plug into relay sockets for easy installation.
Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) or can be mounted to a flat surface.