Clear All
Actuator Style Actuator Style |
---|
![]() | Plunger |
Switching Voltage Switching Voltage | Show |
---|
|
Switching Voltage Switching Voltage | Hide |
---|
Environment Environment |
---|
|
Switch Action Switch Action |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | Wire Leads |
Switch Starting Position Switch Starting Position |
---|
|
Mounting Location Mounting Location |
---|
|
Switch Type Switch Type |
---|
|
Mounting Thread Size Mounting Thread Size |
---|
|
Housing Material Housing Material |
---|
|
Mounting Thread Type Mounting Thread Type |
---|
|
Cable Lead Length Cable Lead Length |
---|
|
Operating Temperature Range Operating Temperature Range |
---|
|
Operating Temperature Range Operating Temperature Range |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Choosing an Electrical Switch
More
Ultra-Precision Wet-Location Limit Switches

These switches actuate with the slightest push for a high degree of accuracy. All are rated IP67 for protection from wet locations and temporary submersion. They’re often used for determining manufacturing tolerances and detecting minute expansions and contractions.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Switching Current @ Voltage | Max. Voltage | Operating Temp. Range, °F | Actuator Ht., mm | Wire Connection Type | No. of Wire Leads | Cable Lead Lg., ft. | Housing Ht., mm | Housing Material | Actuator Material | Mounting Thread Size | Each | |
1 | 1 On (Normally Closed) | Springs Back (Momentary) | SPST-NC | 50 mA @ 24 V AC, 2 mA @ 15 V DC | 24V AC 15V DC | -4° to 167° | 4 | Wire Leads | 2 | 2.5 | 21 | Nickel-Plated Brass | Ruby | M8 | 0000000 | 0000000 |
Ultra-Precision Limit Switches

These switches actuate with the slightest push for a high degree of accuracy. They’re often used for determining manufacturing tolerances and detecting minute expansions and contractions.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Switching Current @ Voltage | Max. Voltage | Operating Temp. Range, °F | Actuator Ht., mm | Wire Connection Type | No. of Wire Leads | Cable Lead Lg., ft. | Housing Ht., mm | Housing Material | Actuator Material | Mounting Thread Size | Environmental Rating | Each | |
1 | 1 On (Normally Closed) | Springs Back (Momentary) | SPST-NC | 50 mA @ 24 V AC, 2 mA @ 15 V DC | 24V AC 15V DC | -4° to 167° | 11.5 | Wire Leads | 2 | 2 1/2 | 10 | Nickel-Plated Brass | Zirconium Ceramic | M8 | IP50 | 0000000 | 0000000 |