RTD Type | Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure | Overall Lg. | Head Material | Specifications Met | Each | |
316 Stainless Steel Probe | ||||||||||||||||
100 ohms | -40° to 120° | 4" | 1/4" | ±0.5% | 10 | DIN Connection | 1/2 | NPT | Male | 10, 30 | 600 psi @ 70° F | 7 1/4" | Plastic | CE Marked, IP65 | 0000000 | 0000000 |
100 ohms | 0° to 140° | 6" | 1/4" | ±0.5% | 10 | DIN Connection | 1/2 | NPT | Male | 10, 30 | 600 psi @ 70° F | 9 1/4" | Plastic | CE Marked, IP65 | 0000000 | 000000 |
100 ohms | 0° to 200° | 9" | 1/4" | ±0.5% | 10 | DIN Connection | 1/2 | NPT | Male | 10, 30 | 600 psi @ 70° F | 12 1/4" | Plastic | CE Marked, IP65 | 0000000 | 000000 |
A built-in transmitter converts the probe’s air-temperature readings to a 4-20 mA signal for use with switches, controllers, and data loggers. Consider the temperature of your application when selecting a probe. Choose a temperature range that closely matches your application to save time configuring the probe. For more flexibility, choose a probe with a large range. You can reconfigure probes for multiple applications.
Replacement elements include a ¼” probe, spring, and 3” of leads.
For technical drawings and 3-D models, click on a part number.
Probes | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Probe Connection | Conduit Connection | Replacement Elements | ||||||||||||||||
RTD Type | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Head Material | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | DC Voltage | Overall Lg. | Choose a Temperature Range | Each | Each | ||
316 Stainless Steel Probe | |||||||||||||||||||
100 ohms | 4" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 9" | 0000000 | 0000000 | 00000000 | 000000 | |
100 ohms | 6" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 11" | 0000000 | 000000 | 00000000 | 00000 | |
100 ohms | 9" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 14" | 0000000 | 000000 | 00000000 | 00000 | |
100 ohms | 12" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 17" | 0000000 | 000000 | 00000000 | 00000 |
Replacement Transmitter for Probes with 0° to 100° F Temperature Range | 00000000 | Each | 0000000 |
Replacement Transmitter for Probes with 0° to 400° F Temperature Range | 00000000 | Each | 000000 |
Replacement Transmitter for Probes with 0° to 200° F Temperature Range | 00000000 | Each | 000000 |
Replacement Transmitter for Probes with 0° to 300° F Temperature Range | 00000000 | Each | 000000 |
Use these converters to change RTD probe signals to a 4-20 mA signal for compatibility with switches and controllers.
For Panel Cutout | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °C | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | AC Voltage (Phase) | Housing Material | Display | Resolution | For Max. Wire Gauge | Each | |
For Probe Type (100 ohms) | |||||||||||||
-50° to 850° | 1/8 | 1 3/4" | 3 5/8" | 1 7/8" | 3 7/8" | 6 1/16" | 120, 240 (Single) | Aluminum | LCD | 1 | 26 | 00000000 | 0000000 |
Convert thermocouple probe signals to a 4-20 mA signal for use with switches and controllers.
Temp. Range, °F | Dia. | Dp. | DC Voltage Range | Housing Material | For Max. Wire Gauge | Each | |
For Probe Type J | |||||||
---|---|---|---|---|---|---|---|
32° to 572° | 1 11/16" | 13/16" | 12 to 36 | Plastic | 26 | 00000000 | 000000 |
32° to 1292° | 1 11/16" | 13/16" | 12 to 36 | Plastic | 26 | 00000000 | 00000 |
For Probe Type K | |||||||
32° to 1112° | 1 11/16" | 13/16" | 12 to 36 | Plastic | 26 | 00000000 | 00000 |
32° to 2192° | 1 11/16" | 13/16" | 12 to 36 | Plastic | 26 | 00000000 | 00000 |
For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | AC Voltage (Phase) | Frequency, Hz | Housing Material | Display | Resolution | For Max. Wire Gauge | Each | |
For Probe Type J | ||||||||||||||
-238° to 1400° | 1/8 | 1 3/4" | 3 5/8" | 1 7/8" | 3 7/8" | 6 1/16" | 120, 240 (Single) | 60 | Aluminum | LCD | 1 | 26 | 00000000 | 0000000 |
For Probe Type K | ||||||||||||||
-58° to 1999° | 1/8 | 1 3/4" | 3 5/8" | 1 7/8" | 3 7/8" | 6 1/16" | 120, 240 (Single) | 60 | Aluminum | LCD | 1 | 26 | 00000000 | 000000 |