Motor Switches

Use these switches to turn motors on and off, or to control lighting and electric heat circuits. They do not provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Specifications Met | Each | |
Stays Switched (Maintained) | |||||||||||
2 | Single (3 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 30 | 600V AC | 3.7" | 1.8" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
2 | Single (5 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 60 | 600V AC | 3.8" | 1.7" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
3 | Three (10 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 60 | 600V AC | 3.8" | 1.7" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 3.7" | 1.8" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 00000 |
Enclosed Motor Switches

These switches are housed in a protective enclosure. Use them to turn motors on and off, or with lighting and electric heat circuits. They do not provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Environment | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | |||||||||||||
2 | Single (3 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 30 | 600V AC | 4.2" | 2.8" | Screw Terminals | Indoor | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 |
2 | Single (5 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 60 | 600V AC | 4.5" | 4.7" | Screw Terminals | Indoor | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 |
3 | Three (10 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 60 | 600V AC | 4.5" | 4.7" | Screw Terminals | Indoor | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 |
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 4.2" | 2.8" | Screw Terminals | Indoor | NEMA 1 | UL Listed, CSA Certified | 0000000 | 00000 |
Washdown Enclosed Motor Switches

Rated NEMA 4X and 12K, these switches are protected from corrosion, washdowns, and oil/coolant dripping. Use them to turn motors on and off, or with other circuits such as lighting and electric heat circuits. They do not provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||||||
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 7.6" | 5.1" | Screw Terminals | NEMA 4X, IP69K, NEMA 12K | UL Listed, C-UL Listed, CSA Certified, UL 746C, UL 94 5VA | 0000000 | 0000000 |
Hazardous Location Enclosed Motor Switches

Use these switches where ignitable gas and dust may be present. They're rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G for hazardous locations. Use them to turn motors on and off, or with other circuits such as lighting and electric heat circuits. They do not provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||||||
2 | Single (3 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 0000000 |
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000 |
Raintight Enclosed Motor Switches

These switches are rated NEMA 3R for protection from falling water and light splashing. Use them to turn motors on and off, or with other circuits such as lighting and electric heat circuits. They do not provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||||||
2 | Single (3 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 30 | 600V AC | 5.8" | 4.5" | Screw Terminals | NEMA 3R | CSA Certified, UL Listed, UL 94 V-2 | 0000000 | 000000 |
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 5.8" | 4.5" | Screw Terminals | NEMA 3R | CSA Certified, UL Listed, UL 94 V-2 | 0000000 | 000000 |
Build-Your-Own Manual Motor Starters

Indicating Light
and Steel Wall Plate

Power Indicating
Light and Steel Housing



Assemble your own motor starter by combining a switch and a thermal overload element.
NEMA 4 and 12 rated switches are protected from washdowns and oil/coolant dripping.
Thermal overload elements shut motors off if current exceeds the full-load current rating. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s horsepower and voltage).
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Electrical Phase (hp) | Ht. | Wd. | Wire Connection Type | Environment | Environmental Rating | Each | |
With Power-Indicating Light | ||||||||
---|---|---|---|---|---|---|---|---|
Steel Wall Plate | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.5" | 2.8" | Screw Terminals | Indoor | __ | 0000000 | 000000 |
2 | Single (3/4 hp @ 115 V DC) Single (3/4 hp @ 230 V DC) Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.5" | 2.8" | Screw Terminals | Indoor | __ | 0000000 | 00000 |
Steel Housing | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor | NEMA 1 | 0000000 | 00000 |
2 | Single (3/4 hp @ 115 V DC) Single (3/4 hp @ 230 V DC) Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor | NEMA 1 | 0000000 | 000000 |
Without Power-Indicating Light | ||||||||
Steel Wall Plate | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.5" | 2.8" | Screw Terminals | Indoor | __ | 0000000 | 00000 |
Steel Housing | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor | NEMA 1 | 0000000 | 00000 |
2 | Single (3/4 hp @ 115 V DC) Single (3/4 hp @ 230 V DC) Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor | NEMA 1 | 0000000 | 00000 |
Zinc Housing | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 5.5" | 3.6" | Screw Terminals | Oily, Washdown | NEMA 4, NEMA 12 | 0000000 | 000000 |
2 | Single (3/4 hp @ 115 V DC) Single (3/4 hp @ 230 V DC) Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 5.5" | 3.6" | Screw Terminals | Oily, Washdown | NEMA 4, NEMA 12 | 0000000 | 000000 |