System of Measurement System of Measurement |
---|
|
ID ID | Show |
---|
|
ID ID | Hide |
---|
Shape Shape |
---|
![]() | Round Tube |
Flexibility Flexibility |
---|
|
Performance Properties Performance Properties |
---|
Hardness Hardness |
---|
|
For Use With For Use With |
---|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Comparable To Comparable To |
---|
Density Density |
---|
Maximum Vacuum Maximum Vacuum |
---|
|
Length Length |
---|
|
|
|
Dielectric Strength Dielectric Strength |
---|
|
More
More
More
More
More
More
More
Strong, hard walls give this tubing extra support in high-pressure and vacuum applications. It’s made of FDA listed materials, so it’s suitable for use with food and beverage. Free of plasticizers like DEHP, it won’t impart tastes or odors to the fluid passing through it.
PVC tubing has harder walls than polyethylene tubing and can handle higher pressures. It meets NSF/ANSI Standard 51 for food contact. Tubing is rigid and will not bend. It is clear, so you can easily monitor flow.
For technical drawings and 3-D models, click on a part number.
Metal interlocked strips create a rigid, durable hose that stays strong under high temperatures. Hose is for use with smoke, welding fumes, and oil fumes.
Galvanized steel offers fair corrosion resistance.
304 stainless steel has very good corrosion resistance.
Offering excellent antifriction qualities, 932 bronze also offers good strength and wear resistance. It's also known as SAE 660 and is often used for bearings, bushings, and thrust washers.
For technical drawings and 3-D models, click on a part number.
Fabricate containers, tanks, and lenses for light fixtures with these scratch- and UV-resistant cast acrylic tubes. Cast acrylic, which is comparable to Lucite and Plexiglas® Acrylic, is easier to machine than extruded acrylic. This material stands up to outdoor use better than polycarbonate and maintains clarity over time.
Comparable to Lexan, Hyzod, Tuffak, and Makrolon, these polycarbonate tubes are half the weight of glass and maintain excellent impact resistance across a wide temperature range. Use them to make instrument gauge covers and display racks.
These impact- and wear-resistant tubes offer 360° protection from scrapes and strikes to wires, cords, and anything that can slide through them. UHMW has a low-friction surface that resists sticking and binding.
Tubes with an oversized OD also have an undersized ID for finishing to the sizes listed.
Tightly braided nylon fibers give this sleeving excellent abrasion resistance. As it wears, the fibers frizz and make the outer wall thicker for improved protection. The interior is smooth to reduce snags during installation. It meets Mine Safety and Health Administration (MSHA) standards for fire protection in mines. Because this sleeving is non-expandable, it does not stretch, so it’s best for applications where you know the exact diameter of the items you need to protect.
This sleeving has excellent tear resistance and better abrasion resistance than standard polyester sleeving. Made of Nomex fabric, it resists most acids and alkalies, alcohol, hydraulic fluid, oil, gasoline, salt water, and solvents. It won’t irritate skin like fiberglass, so it’s easier to handle. Because this sleeving is non-expandable, it does not stretch, so it’s best for applications where you know the exact diameter of the items you need to protect.
Offering greater strength and better electrical-insulating properties than Garolite CE tubes, these Garolite XX tubes are often fabricated into low-cost electrical components. Garolite XX is constructed of a phenolic resin with paper reinforcement, which makes it easy to machine. It's also known as paper-grade industrial laminate, phenolic, and Bakelite.
For technical drawings and 3-D models, click on a part number.
OD | OD Tolerance | ID | ID Tolerance | Lg. | Each | |
1/16" Wall Thick. (-0.008" to 0.008") | ||||||
---|---|---|---|---|---|---|
2" | -0.008" to 0.008" | 1 7/8" | -0.005" to 0.005" | 40" | 00000000 | 000000 |
Even at high temperatures, these tubes remain flexible to stretch over components without tearing. They restrict absorption of water, air, and gas and are typically used on hot and cold water lines and electrical components.
ID | ID Tolerance Range | For Pipe Size | Lg., ft. | R Value | Flexibility | Each | |
3/8" Wall Thick. | |||||||
---|---|---|---|---|---|---|---|
1 7/8" | -0.4" to 0.4" | 1 1/2 | 6 | 1 | Flexible | 00000000 | 0000000 |
Soft and easy to install, this insulation restricts absorption of water, air, and gas. It is often used on cold and hot water lines and refrigeration lines. Seal with contact adhesive (sold separately). To use outdoors, coat in acrylic paint.
Slit tubes have an adhesive strip closure.
Less flexible than rubber foam, this insulation restricts absorption of water, air, and gas. It is typically used in plumbing applications. Seal with contact adhesive (sold separately). To use outdoors, coat in acrylic paint.
These rigid, lightweight melamine foam tubes are wrapped in an ISO Class 5 (Class 100) clean room jacket that is suitable for sanitary and washdown applications. They’re typically used on cold and hot water piping and with refrigeration systems. The jacket has an adhesive strip closure. Seal seams with a silicone sealant and join lengths with tape (both sold separately).
Melamine has a lightweight construction that allows quick and easy installation. Use on cold and hot water piping and with refrigeration systems. Insulation has an all-service jacket (ASJ) made of kraft paper with an adhesive strip closure. Seal seams with silicone sealant and join lengths with tape (both sold separately).
Very rigid with a 0% water absorption rate, this insulation is unaffected by corrosive environments, organic solvents, and most acids. It is typically used in chemical-processing systems and underground lines. Insulation is flame resistant, meeting ASTM E84 0/0 for flame and smoke. Seal with tape (sold separately). Outdoor and underground use require metal jacketing (sold separately).
Tubes have a kraft paper jacket with an adhesive strip for sealing.
Hook-and-loop fasteners make it easy to install, remove, and reuse this flexible insulation. Use on steam, hot water, and process pipes and fittings.
3/8" Wall Thick. | ||||||
---|---|---|---|---|---|---|
ID | For Pipe Size | Lg., ft. | Flexibility | R Value | Each | |
1 7/8" | 1 1/2 | 20 | Flexible | 1.7 | 00000000 | 0000000 |
3/8" Wall Thick. | |||||
---|---|---|---|---|---|
ID | For Pipe Size | Flexibility | R Value | Each | |
1 7/8" | 1 1/2 | Flexible | 1.7 | 000000000 | 000000 |
3/8" Wall Thick. | |||||
---|---|---|---|---|---|
ID | For Pipe Size | Flexibility | R Value | Each | |
1 7/8" | 1 1/2 | Flexible | 1.7 | 000000000 | 000000 |
3/8" Wall Thick. | |||||
---|---|---|---|---|---|
ID | For Pipe Size | Flexibility | R Value | Each | |
1 7/8" | 1 1/2 | Flexible | 1.7 | 000000000 | 000000 |
3/8" Wall Thick. | |||||
---|---|---|---|---|---|
ID | For Pipe Size | Flexibility | R Value | Each | |
1 7/8" | 1 1/2 | Flexible | 1.7 | 000000000 | 000000 |
3/8" Wall Thick. | |||||
---|---|---|---|---|---|
ID | For Pipe Size | Flexibility | R Value | Each | |
1 7/8" | 1 1/2 | Flexible | 1.7 | 000000000 | 000000 |
Rigid and flame resistant, these insulation tubes meet ASTM E84 5/0 for flame and smoke. They are typically used in process piping and mechanical systems and perform best at temperatures up to 600° F. To use outdoors, add metal jacketing.
This common insulation material is typically used on hot and cold water lines and in process piping. To use outdoors, add metal jacketing.
Tubes, elbows, and tees are formed to provide the best fit on pipe and are the easiest to install. If your pipe is larger than the sizes we offer, choose a sheet/strip.
Tubes have an all-service jacket (ASJ) made of kraft paper with an adhesive strip closure. Seal with reinforced insulation tape (sold separately).
Elbows and tees with PVC jacketing seal using reinforced HVAC tape (sold separately).
ID | For Pipe Size | Lg., ft. | Flexibility | R Value | Each | |
1/2" Wall Thick. | ||||||
---|---|---|---|---|---|---|
1 7/8" | 1 1/2 | 3 | Rigid | 2.2 | 0000000 | 00000 |
1" Wall Thick. | ||||||
1 7/8" | 1 1/2 | 3 | Rigid | 4.3 | 0000000 | 0000 |
1 1/2" Wall Thick. | ||||||
1 7/8" | 1 1/2 | 3 | Rigid | 6.5 | 0000000 | 00000 |
2" Wall Thick. | ||||||
1 7/8" | 1 1/2 | 3 | Rigid | 8.7 | 0000000 | 00000 |
3" Wall Thick. | ||||||
1 7/8" | 1 1/2 | 3 | Rigid | 13 | 00000000 | 00000 |
Reinforced Insulation Tape (3" × 30 ft.) | 00000000 | Each | 00000 |
This very rigid insulation offers the lowest heat-flow rate of our pipe insulation and restricts absorption of water, air, and gas. It is typically used in process piping and chiller plants and performs best in applications below 50° F. To use outdoors, add metal jacketing.
Tubes have a kraft paper all-service jacket (ASJ) that resists mold and mildew by allowing moisture to evaporate. They have an adhesive strip closure.