McMaster-Carr logo
    Filter by
    Thermocouple Probe Type
    Thermometer Type
    Number of Probe Inputs
    System of Measurement
    Measurement Unit
    Display Type
    Manufacturer/Brand Model Number
    Maximum Cable Temperature
    Temperature Resolution
    Probe Length
    Probe Material
    Batteries Included
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    13 Products

    Data-Logging Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 2 Probe Inputs.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 4 Probe Inputs.
    Image of Product. Front orientation. Thermometers. Data-Logging Handheld Thermometers, 12 Probe Inputs.

    2 Probe Inputs

    4 Probe

    Inputs

    12 Probe Inputs

    Measure and store temperature readings and upload the data to a PC.
    SD Memory Card—For easy upload, thermometers with an SD memory card store readings in Excel format.
    Thermometers
    Replacement
    Probes
    Probe
    No. of Probe
    Inputs
    Temp. Range
    Resolution,
    ° C
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Thermometer Features
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, and Surfaces
     
    Thermometers with Carrying Case, Protective Holster, RS-232 Port, and Windows-Compatible Software and Cable
    2-22° F to 572° F/-30° C to 300° C0.1/0.1±1.75° F/±0.90° C1.531/8"3/16"Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time ClockCE Marked
    Yes9281T4400000009281T21000000
     
    Thermometers with SD Memory Card, Carrying Case, and RS-232 Port
    4-40° F to 392° F/-40° C to 200° C0.1/0.1±5.8° F/±4.4° C131/8"3/16"Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time ClockCE Marked
    Yes9281T520000009281T2100000
     
    Thermometers with SD Memory Card and Carrying Case
    12-40° F to 482° F/-40° C to 250° C0.1/0.1±1.8° F/±1° C131/8"3/16"Automatic Shutoff, Backlit Display, Data Logging CapabilitiesCE Marked
    Yes9281T54000000009281T2100000
     

    Fluke High-Accuracy Data-Logging Thermometers

    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Data-Logging Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Data-Logging Thermometers, 2 Probe Inputs.
    Image of Product. Type K Probe. Front orientation. Fluke High-Accuracy Data-Logging Thermometers.

    1 Probe Input

    2 Probe Inputs

    Type K Probe

    Store up to 500 readings on these thermometers and determine temperature within ±0.75° F accuracy.
    Thermometers with Calibration Certificate Traceable to NIST—Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
    Probe
    Thermometers
    Thermometers with Calibration
    Certificate Traceable to NIST
    No. of Probe
    Inputs
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Mfr./Brand
    Model No.
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, Solids, and Surfaces
    1-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.4° C23.253/16"1/16"53-2BCE Marked, CSA Certified
    Yes40255K33000000040255K430000000
    2-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.4° C23.253/16"1/16"54-2BCE Marked, CSA Certified
    Yes40255K3400000040255K4400000000
     
    Probes

    Fluke High-Accuracy Handheld Thermometers

    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Handheld Thermometers, 1 Probe Input.
    Image of Product. Front orientation. Thermometers. Fluke High-Accuracy Handheld Thermometers, 2 Probe Inputs.
    Image of Product. Type K Probe. Front orientation. Fluke High-Accuracy Handheld Thermometers.

    1 Probe Input

    2 Probe Inputs

    Type K Probe

    Designed for laboratory applications, these thermometers determine temperature within ±0.75° F accuracy.
    Thermometers with Calibration Certificate Traceable to NIST—Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
    Probe
    Thermometers
    Thermometers with Calibration
    Certificate Traceable to NIST
    No. of Probe
    Inputs
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Mfr./Brand
    Model No.
    Certification
    Batteries
    Included
    Each
    Each
    For Use With Air, Gas, Solids, and Surfaces
    1-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.45° C23.253/16"1/16"51-2CE Marked, CSA Certified
    Yes40255K31000000040255K410000000
    2-40° F to 500° F/-40° C to 260° C/233 K to 533 K0.1/0.1° C/0.1 K±0.75° F/±0.45° C23.253/16"1/16"52-2CE Marked, CSA Certified
    Yes40255K3200000040255K42000000
     