Panel-Mount Vacuum-Regulating Valves for Air


- For Use With: Air
 - Temperature Range: Not Rated
 
Regulate vacuum levels from your instrument panel with these valves that have threads below the adjustment handle and a panel-mount nut. They throttle a high vacuum source to maintain a lower vacuum level in your system. Adjust the outlet vacuum level within the range. Valves are constant-bleed style, so they continually release small amounts of process gas to improve accuracy and repeatability.
Valve with gauge comes with a vacuum gauge for monitoring your vacuum level.
Inlet  | Outlet  | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size  | Location | Pipe Size  | Location | Vacuum Range, in. of Hg  | Vacuum Adjustment Method  | Port-to-Port Lg.  | Bleed Type  | Panel Cutout Diameter  | Each | |
Valve  | ||||||||||
NPT Female  | ||||||||||
Anodized Aluminum Body—Aluminum Diaphragm and Buna-N Seal  | ||||||||||
| 1/8 | Side | 1/8 | Bottom | 0 to 20 | Knob | 11/16" | Constant Bleed | 1" | 0000000 | 0000000 | 
Valve with Gauge  | ||||||||||
NPT Female  | ||||||||||
Anodized Aluminum Body—Aluminum Diaphragm and Buna-N Seal  | ||||||||||
| 1/8 | Side | 1/8 | Bottom | 0 to 20 | Knob | 11/16" | Constant Bleed | 1" | 0000000 | 000000 | 
Plastic Panel-Mount Vacuum-Regulating Valves for Air and Inert Gas

- For Use With: Air, Inert Gas
 - Temperature Range: 40° to 150° F
 
A lighter and more corrosion-resistant alternative to metal valves. All valves throttle a high vacuum source to maintain a lower vacuum level in your system. Adjust the outlet vacuum level within the range. Threads below the adjustment knob and an included panel-mount nut let you add these valves to your instrument panel. All are constant-bleed style, so they continually release small amounts of process gas to improve accuracy and repeatability.
Inlet  | Outlet  | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size  | Thread Size  | Location | Pipe Size  | Thread Size  | Location | Vacuum Range, in. of Hg  | Vacuum Adjustment Method  | End-to-End Lg.  | Panel Cutout Dia.  | Each | |
NPT Female  | |||||||||||
Polysulfone Body—Buna-N/EPDM Diaphragm and Polyurethane Seal  | |||||||||||
| 1/8 | __ | Side | 1/8 | __ | Side | 0 to 30 | Knob | 1 9/16" | 9/16" | 00000000 | 000000 | 
UNF Female  | |||||||||||
Polysulfone Body—Buna-N/EPDM Diaphragm and Polyurethane Seal  | |||||||||||
| __ | 10-32 | Side | __ | 10-32 | Side | 0 to 30 | Knob | 1 1/8" | 9/16" | 00000000 | 00000 | 
High-Accuracy Panel-Mount Vacuum-Regulating Valves for Air and Inert Gas

- For Use With: Air, Argon, Nitrogen
 - Temperature Range: -40° to 165° F
 
For precise control over your vacuum level, these valves have ±0.1% accuracy. They throttle a high vacuum source to maintain a lower vacuum level in your system. Adjust the outlet vacuum level within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. All have a gauge port. They are constant-bleed style, so they continually release small amounts of process gas to improve accuracy and repeatability.
Extended-Life Vacuum-Regulating Valves for Air and Inert Gas

- For Use With: Air, Inert Gas
 - Temperature Range: -20° to 180° F
 
For a longer service life than brass vacuum-regulating valves, these are made of bronze for strength and durability. They throttle a high vacuum source to maintain a lower vacuum level in your system. Turning the adjustment screw will adjust the vacuum setting.
Inlet  | Outlet  | |||||||
|---|---|---|---|---|---|---|---|---|
| Pipe Size  | Location | Pipe Size  | Location | Vacuum Range, in. of Hg  | Vacuum Adjustment Method  | End-to-End Lg.  | Each | |
NPT Female  | ||||||||
Bronze Body—Neoprene Diaphragm and Chrome-Plated Bronze Seal  | ||||||||
| 1/2 | Side | 1/2 | Side | 2 to 30 | Screw | 2 7/8" | 0000000 | 0000000 | 
| 3/4 | Side | 3/4 | Side | 2 to 30 | Screw | 2 7/8" | 0000000 | 000000 | 
| 1 | Side | 1 | Side | 2 to 30 | Screw | 4 1/2" | 0000000 | 00000000 | 
| 1 1/4 | Side | 1 1/4 | Side | 2 to 30 | Screw | 4 1/2" | 0000000 | 00000000 | 
| 1 1/2 | Side | 1 1/2 | Side | 8 to 30 | Screw | 5 3/4" | 0000000 | 00000000 | 
| 2 | Side | 2 | Side | 8 to 30 | Screw | 5 3/4" | 0000000 | 00000000 | 
Vacuum-Regulating Valves for Air and Inert Gas

- For Use With: Air, Carbon Dioxide, Inert Gas, Nitrogen
 - Temperature Range: -20° to 180° F
 
Throttle a high vacuum source to maintain a lower vacuum level in your system. Adjust the outlet vacuum level within the range. All valves have a gauge port.