Airflow @ Static Pressure Airflow @ Static Pressure |
---|
Housing Material Housing Material |
---|
|
Blade Material Blade Material |
---|
|
Motor Speed Motor Speed |
---|
Motor Enclosure Type Motor Enclosure Type |
---|
|
Overall Diameter Overall Diameter |
---|
|
|
|
Overall Depth Overall Depth |
---|
|
|
|
Overall Height Overall Height |
---|
Volume Volume |
---|
|
Current Current |
---|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Specifications Met Specifications Met |
---|
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
About Exhaust Fans
More
Direct-Drive Corrosion-Resistant Duct Fans

A galvanized steel housing offers good corrosion resistance. All of these direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, they install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Motor Speed, rpm | Power, hp | Dia. | Ht. | Dp. | Max. Temp., °F | Housing Material | Blade Material | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||
4" | 90 cfm @ 3/8 in. of H₂O 115 cfm @ 1/8 in. of H₂O | 3,000 | 1/40 | 8 3/4" | 10 3/4" | 6 1/2" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 0000000 |
5" | 105 cfm @ 3/8 in. of H₂O 135 cfm @ 1/8 in. of H₂O | 3,000 | 1/40 | 8 3/4" | 10 3/4" | 5 1/2" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
6" | 240 cfm @ 3/8 in. of H₂O 280 cfm @ 1/8 in. of H₂O | 2,700 | 1/10 | 11 3/8" | 13 3/8" | 6" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
8" | 360 cfm @ 3/8 in. of H₂O 425 cfm @ 1/8 in. of H₂O | 2,550 | 1/6 | 13 3/8" | 15 3/8" | 6" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
8" | 435 cfm @ 3/8 in. of H₂O 480 cfm @ 1/8 in. of H₂O | 2,950 | 1/5 | 13 3/8" | 15 3/8" | 6" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
10" | 540 cfm @ 3/8 in. of H₂O 570 cfm @ 1/8 in. of H₂O | 3,100 | 1/4 | 13 3/8" | 15 3/8" | 5 7/8" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
12" | 620 cfm @ 3/8 in. of H₂O 700 cfm @ 1/8 in. of H₂O | 2,600 | 1/4 | 16" | 18" | 8 1/4" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
120V AC, Single Phase—Plug | ||||||||||||
4" | 90 cfm @ 3/8 in. of H₂O 115 cfm @ 1/8 in. of H₂O | 3,000 | 1/40 | 8 3/4" | 10 3/4" | 6 1/2" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
5" | 105 cfm @ 3/8 in. of H₂O 135 cfm @ 1/8 in. of H₂O | 3,000 | 1/40 | 8 3/4" | 10 3/4" | 5 1/2" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
6" | 240 cfm @ 3/8 in. of H₂O 280 cfm @ 1/8 in. of H₂O | 2,700 | 1/10 | 11 3/8" | 13 3/8" | 6" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
8" | 360 cfm @ 3/8 in. of H₂O 425 cfm @ 1/8 in. of H₂O | 2,550 | 1/6 | 13 3/8" | 15 3/8" | 6" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
8" | 435 cfm @ 3/8 in. of H₂O 480 cfm @ 1/8 in. of H₂O | 2,950 | 1/5 | 13 3/8" | 15 3/8" | 6" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
10" | 540 cfm @ 3/8 in. of H₂O 570 cfm @ 1/8 in. of H₂O | 3,100 | 1/4 | 13 3/8" | 15 3/8" | 5 7/8" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
12" | 620 cfm @ 3/8 in. of H₂O 700 cfm @ 1/8 in. of H₂O | 2,600 | 1/4 | 16" | 18" | 8 1/4" | 140° | Galvanized Steel | Polypropylene Plastic | C-UL Listed, UL Listed | 0000000 | 000000 |
Belt-Drive Corrosion-Resistant Duct Fans

A 304 stainless steel housing offers good corrosion resistance. All of these belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Dp. | Max. Temp., °F | Housing Material | Blade Material | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
12" | 1,600 cfm @ 3/8 in. of H₂O 1,800 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 3,050 | 3/4 | 14 1/16" | 25 5/8" | 20" | 200° | 304 Stainless Steel | Stainless Steel | No | 7/16" | 0000000 | 000000000 |
18" | 4,600 cfm @ 3/8 in. of H₂O 4,800 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 2,350 | 1 1/2 | 20 1/16" | 32 11/16" | 20" | 200° | 304 Stainless Steel | Stainless Steel | No | 7/16" | 0000000 | 00000000 |
24" | 7,200 cfm @ 3/8 in. of H₂O 7,900 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,700 | 2 | 26 11/16" | 38 3/4" | 21" | 200° | 304 Stainless Steel | Stainless Steel | No | 7/16" | 0000000 | 00000000 |
Heater and Air Conditioner Duct Booster Fans

Insert these fans directly into your ductwork. They give small heaters and air conditioners a boost to circulate air through ductwork. The crimped end construction makes inserting the fans easy.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
An optional thermostat (sold separately) adjusts from 40° to 110° F.
For Duct Dia. | No. of Speeds | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Overall Dp. | Max. Temp., °F | Housing Material | Blade Material | Each | |
120V AC, Single Phase—Plug | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
4" | 1 | 65 cfm @ 0 in. of H₂O | 47 dB @ 15 ft. | 3,200 | 6" | 140° | Galvanized Steel | Polycarbonate Plastic | 0000000 | 000000 |
12" | 1 | 650 cfm @ 0 in. of H₂O | 50 dB @ 15 ft. | 1,300 | 8" | 140° | Galvanized Steel | Aluminum | 0000000 | 00000 |
120V AC, Single Phase—Hardwire | ||||||||||
6" | 1 | 240 cfm @ 0 in. of H₂O | Not Rated | 1,600 | 7 1/4" | 255° | Galvanized Steel | Aluminum | 0000000 | 00000 |
6" | 2 | 180 cfm @ 0 in. of H₂O | 44 dB @ 15 ft. | 1,650 | 6" | 140° | Galvanized Steel | Polycarbonate Plastic | 0000000 | 00000 |
8" | 1 | 420 cfm @ 0 in. of H₂O | Not Rated | 1,600 | 7 1/4" | 255° | Galvanized Steel | Aluminum | 0000000 | 00000 |
10" | 1 | 650 cfm @ 0 in. of H₂O | Not Rated | 1,600 | 8" | 212° | Galvanized Steel | Aluminum | 0000000 | 000000 |
14" | 1 | 1,350 cfm @ 0 in. of H₂O | Not Rated | 1,600 | 9 1/8" | 212° | Galvanized Steel | Aluminum | 0000000 | 000000 |
Optional Thermostat | 0000000 | Each | 000000 |
Low-Voltage Heater and Air Conditioner Duct Booster Fans

Often used in vehicles, these fans operate on DC power. Insert them directly into your ductwork. They give small heaters and air conditioners a boost to circulate air through ductwork. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
An optional thermostat (sold separately) adjusts from 40° to 110° F.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Volume | Ht. | Wd. | Dp. | Max. Temp., °F | Housing Material | Blade Material | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
12V DC—Hardwire | ||||||||||||
3" | 130 cfm @ 0 in. of H₂O | 55 dB @ 15 ft. | 3 3/16" | 5" | 5 1/4" | 200° | Polypropylene Plastic | Polypropylene Plastic | No | 3/16" | 00000000 | 000000 |
4" | 230 cfm @ 0 in. of H₂O | 55 dB @ 15 ft. | 4 3/16" | 6" | 5 1/4" | 200° | Polypropylene Plastic | Polypropylene Plastic | No | 3/16" | 00000000 | 00000 |
Optional Thermostat | 0000000 | Each | 000000 |
Cutout-Mount Heater and Air Conditioner Duct Booster Fans

Mount this fan into a hole in your ductwork. It gives small heaters and air conditioners a boost to circulate air through ductwork.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
An optional thermostat (sold separately) adjusts from 40° to 110° F.
Direct-Drive Duct Fans

Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Motor Speed | Power, hp | Dia. | Ht. | Dp. | Max. Temp., °F | Housing Material | Blade Material | Specifications Met | Hardware Included | Hole Diameter | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||
4" | 95 cfm @ 3/8 in. of H₂O 135 cfm @ 1/8 in. of H₂O | Not Rated | 1/40 | 9 1/2" | 9 1/2" | 9 5/8" | 140° | ABS/Polycarbonate Plastic | ABS/Polycarbonate Plastic | C-UL Listed, UL Listed | Yes | 0.244" | 00000000 | 0000000 |
5" | 105 cfm @ 3/8 in. of H₂O 150 cfm @ 1/8 in. of H₂O | Not Rated | 1/40 | 9 1/2" | 9 1/2" | 7 7/8" | 140° | ABS/Polycarbonate Plastic | ABS/Polycarbonate Plastic | C-UL Listed, UL Listed | Yes | 0.244" | 00000000 | 000000 |
6" | 250 cfm @ 3/8 in. of H₂O 300 cfm @ 1/8 in. of H₂O | Not Rated | 1/10 | 11 3/4" | 11 3/4" | 9 5/8" | 140° | ABS/Polycarbonate Plastic | ABS/Polycarbonate Plastic | C-UL Listed, UL Listed | Yes | 0.244" | 00000000 | 000000 |
High-Output Direct-Drive Duct Fans

Produce three times the airflow as standard direct-drive duct fans. All of these direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, they install inline in ductwork for use as an exhaust, supply, or booster fan. All have a TEFC (totally enclosed fan cooled) motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | Mounting | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Dp. | Bolt Circle Dia. | Max. Temp., °F | Housing Material | Blade Material | Fasteners Included | For Screw Size | Hole Dia. | No. of Holes | Each | |
120/230V AC, Single Phase—Hardwire | |||||||||||||||||
12" | 1,900 cfm @ 3/8 in. of H₂O 2,000 cfm @ 1/8 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 1/2 | 14 1/16" | 14 1/16" | 20" | 13 1/8" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 0000000 |
15" | 2,100 cfm @ 3/8 in. of H₂O 2,700 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,750 | 1/2 | 17 1/16" | 17 1/16" | 20" | 16 1/8" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 00000000 |
18" | 3,900 cfm @ 3/8 in. of H₂O 4,500 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,750 | 3/4 | 20 1/16" | 20 1/16" | 20" | 19 1/8" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 00000000 |
24" | 4,900 cfm @ 3/8 in. of H₂O 5,800 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,750 | 3/4 | 26 11/16" | 26 11/16" | 21" | 25 13/16" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||||
12" | 1,900 cfm @ 3/8 in. of H₂O 2,000 cfm @ 1/8 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 1/2 | 14 1/16" | 14 1/16" | 20" | 13 1/8" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 000000 |
15" | 2,100 cfm @ 3/8 in. of H₂O 2,700 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,750 | 1/2 | 17 1/16" | 17 1/16" | 20" | 16 1/8" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 00000000 |
18" | 3,900 cfm @ 3/8 in. of H₂O 4,500 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,750 | 3/4 | 20 1/16" | 20 1/16" | 20" | 19 1/8" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 00000000 |
24" | 4,900 cfm @ 3/8 in. of H₂O 5,800 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,750 | 3/4 | 26 11/16" | 26 11/16" | 21" | 25 13/16" | 100° | Steel | Aluminum | No | 3/8" | 7/16" | 8 | 0000000 | 00000000 |
Belt-Drive Duct Fans

Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Dp. | Max. Temp., °F | Housing Material | Blade Material | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||
12" | 1,400 cfm @ 3/8 in. of H₂O 1,600 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 3,450 | 1/2 | 14 1/16" | 23 7/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 000000000 |
15" | 2,800 cfm @ 3/8 in. of H₂O 3,200 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 2,275 | 3/4 | 17 1/16" | 26 15/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
18" | 2,500 cfm @ 3/8 in. of H₂O 3,400 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,600 | 1/2 | 20 1/16" | 30 3/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
18" | 4,400 cfm @ 3/8 in. of H₂O 4,800 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 2,150 | 1 | 20 1/16" | 30 3/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
24" | 7,000 cfm @ 3/8 in. of H₂O 7,900 cfm @ 1/8 in. of H₂O | 70 dB @ 15 ft. | 1,800 | 1 1/2 | 26 11/16" | 36 11/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
36" | 13,300 cfm @ 3/8 in. of H₂O 15,200 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,000 | 2 | 39 1/4" | 49 1/4" | 16" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
Belt-Drive Hazardous Location Duct Fans

These fans have an explosion-proof motor that is rated for hazardous environments. All are belt-drive fans that are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. Fans rated IP44 have a motor enclosure that's rated for protection in damp environments. Fans rated IP56 have a motor enclosure that’s rated for protection in damp, dusty, and washdown environments. UL, CSA, and EEV standards apply to the motor.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Dp. | Max. Temp., °F | Housing Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||
12" | 1,400 cfm @ 3/8 in. of H₂O 1,600 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 3,025 | 1/2 | 14 1/16" | 23 7/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 000000000 |
15" | 2,800 cfm @ 3/8 in. of H₂O 3,200 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 2,275 | 3/4 | 17 1/16" | 26 15/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
18" | 2,500 cfm @ 3/8 in. of H₂O 3,400 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,600 | 1/2 | 20 1/16" | 30 3/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
18" | 4,400 cfm @ 3/8 in. of H₂O 4,800 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 2,150 | 1 | 20 1/16" | 30 3/16" | 12" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
24" | 7,000 cfm @ 3/8 in. of H₂O 7,900 cfm @ 1/8 in. of H₂O | 70 dB @ 15 ft. | 1,800 | 1 1/2 | 26 11/16" | 36 11/16" | 16" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
36" | 13,300 cfm @ 3/8 in. of H₂O 15,200 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,000 | 2 | 39 1/4" | 49 1/4" | 16" | 175° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
Direct-Drive Hazardous Location Duct Fans

These fans have an explosion-proof motor that is UL listed for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G hazardous environments. All are direct-drive fans that have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, they install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a TEFC (totally enclosed fan cooled) motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Dp. | Max.Temp., °F | Housing Material | Blade Material | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||
12" | 1,900 cfm @ 3/8 in. of H₂O 2,000 cfm @ 1/8 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 1/2 | 14 1/16" | 14 1/16" | 20" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 000000000 |
15" | 2,100 cfm @ 3/8 in. of H₂O 2,700 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,750 | 1/2 | 17 1/16" | 17 1/16" | 20" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
18" | 3,900 cfm @ 3/8 in. of H₂O 4,500 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,750 | 3/4 | 20 1/16" | 20 1/16" | 20" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
24" | 4,900 cfm @ 3/8 in. of H₂O 5,800 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,750 | 3/4 | 26 11/16" | 26 11/16" | 21" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
12" | 1,900 cfm @ 3/8 in. of H₂O 2,000 cfm @ 1/8 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 1/2 | 14 1/16" | 14 1/16" | 20" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
15" | 2,100 cfm @ 3/8 in. of H₂O 2,700 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,750 | 1/2 | 17 1/16" | 17 1/16" | 20" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
18" | 3,900 cfm @ 3/8 in. of H₂O 4,500 cfm @ 1/8 in. of H₂O | 60 dB @ 15 ft. | 1,750 | 3/4 | 20 1/16" | 20 1/16" | 20" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
24" | 4,900 cfm @ 3/8 in. of H₂O 5,800 cfm @ 1/8 in. of H₂O | 65 dB @ 15 ft. | 1,750 | 3/4 | 26 11/16" | 26 11/16" | 21" | 100° | Steel | Aluminum | No | 7/16" | 0000000 | 00000000 |
Exterior-Wall-Mount Exhaust Fans



Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to an outside wall and work with or without duct. To use with duct, add an angle ring (not included). All fans are direct-drive fans and have fewer moving parts than belt-drive fans for less maintenance. Use them to draw stagnant and humid air out of a room or area.
120V AC fans have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
120/230V AC fan has a totally enclosed fan cooled motor for use in dirty, dusty, and damp environments
Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
Grilles (sold separately) have fixed blades.
Louvers (sold separately) are gravity operated. The blades open when air flows and close when it stops, preventing backdrafts.
For technical drawings and 3-D models, click on a part number.
Fans | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Opening | Overall | Grilles | Louvers | ||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Wd. | Dia. | Dp. | Max. Ambient Temperature | Specifications Met | Each | Each | Each | |||
120V AC, Single Phase—Hardwire | |||||||||||||||||
7" | 190 cfm @ 0 in. of H₂O | 39 dB @ 15 ft. | 1,050 | 1/25 | 8" | 8" | 8" | 17 1/8" | 13" | 180° F | C-UL Listed UL Listed | 000000 | 0000000 | 0000000 | 000000 | 0000000 | 000000 |
10" | 250 cfm @ 1/4 in. of H₂O 550 cfm @ 0 in. of H₂O | 42 dB @ 15 ft. | 1,050 | 1/25 | 10" | 10" | 10" | 21 1/8" | 16" | 180° F | C-UL Listed UL Listed | 000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
13" | 1,400 cfm @ 1/4 in. of H₂O 1,600 cfm @ 0 in. of H₂O | 51 dB @ 15 ft. | 1,075 | 1/6 | 12" | 12" | 12" | 30 3/16" | 28 3/4" | 180° F | C-UL Listed UL Listed | 000000 | 00000000 | 0000000 | 00000 | 0000000 | 00000 |
16" | 2,400 cfm @ 1/4 in. of H₂O 2,800 cfm @ 0 in. of H₂O | 57 dB @ 15 ft. | 1,075 | 1/3 | 14" | 16" | 16" | 34 11/16" | 30 7/8" | 180° F | C-UL Listed UL Listed | 000000 | 00000000 | 0000000 | 000000 | 0000000 | 00000 |
120/230V AC, Single Phase—Hardwire | |||||||||||||||||
18" | 4,000 cfm @ 1/4 in. of H₂O 4,300 cfm @ 0 in. of H₂O | 60 dB @ 15 ft. | 1,125 | 3/4 | 20" | 20" | 20" | 39 7/16" | 35 5/8" | 180° F | C-UL Listed UL Listed | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |