Measures Measures |
---|
|
|
Minimum Velocity (Linear) Minimum Velocity (Linear) |
---|
|
Maximum Vibration Maximum Vibration |
---|
|
Housing Material Housing Material |
---|
|
Maximum Velocity (Linear) Maximum Velocity (Linear) |
---|
|
Activation Point Range Activation Point Range |
---|
|
Environmental Rating Environmental Rating |
---|
Environment Environment |
---|
|
Specifications Met Specifications Met |
---|
|
This meter comes with a calibration certificate traceable to NIST that states it has passed a test for accuracy.
Measures | Vibration Range, cpm | Acceleration Range, g | Frequency Range, Hz | Velocity Range, in./sec. | Displacement Range, mil | Accuracy | Temp. Range, °F | Max. Reading Display Time | Probe Lg. | Batteries Included | Container Type | Each | |
Vibration, Acceleration, Frequency, Velocity, Displacement | 180-60,000 | 0.02-199.9 | 3-1,000 | 0.02-199.9 | 0.2-199.9 | ±5% | 35° to 120° | 1 min. | 1 1/2" | Yes | Case | 000000 | 0000000 |
In addition to measuring vibration, you can listen to and record machine performance. The magnetic base allows you to mount the probe on a machine for constant readings.
Measures | Vibration Range, cpm | Acceleration Range, g | Frequency Range, Hz | Velocity Range, in./sec. | Accuracy | Temp. Range, °F | Probe Lg. | Batteries Included | Container Type | Each | |
Vibration, Acceleration, Frequency, Velocity | 600-600,000 | 0.01-19.99 | 10-10,000 | 0.01-19.99 | ±2% | -10° to 120° | 4 1/2" | Yes | Case | 000000 | 000000000 |
A flexible steel wire reed detects vibration while the scale on the side of the meter indicates the machine vibration in cycles per minute (cpm). A simple calculation determines motor speed in rpm for engines with multiple cycles.
Set includes one meter for low-speed vibration and one meter for higher speed vibration. A flexible steel wire reed detects vibration while the scale on the side of the meter indicates the machine vibration in cycles per minute (cpm). A simple calculation determines motor speed in rpm for engines with multiple cycles.
Includes | Container Type | Set | |
One Vibration Meter with 200 cpm-2000 cpm Vibration Range and ±15% Accuracy of Reading One Vibration Meter with 2000 cpm-21000 cpm Vibration Range and ±10% Accuracy of Reading | Case | 0000000 | 0000000 |
This monitor is constructed entirely of stainless steel for excellent corrosion resistance and is IP69K rated for high-pressure washdown service. Plug it into your data collector or programmable logic controller to monitor vibration.
Use an optional magnetic base for temporary mounting.
Activation Point | Housing | Power Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, mm/s | Frequency Range, Hz | Vibration Monitoring Range, in./sec. | Current Output, mA | Input Voltage Range | Ht. | Dia. | Temp. Range, °F | Mounting Stud Thread Size | Industry Designation | Number of Wires | Cord Lg., ft. | Specifications Met | Includes | Each | |
0-25 | 10-1,000 | 0-1 | 4-20 | 9.6V DC-32V DC | 2 1/2" | 7/8" | -20° to 220° | M8 | M12 | 2 | 16 | ISO 10816, CE Marked, C-UL Listed, UL Listed | One 1/4"-28 Adapter | 000000 | 0000000 |
Two easy-to-set dials allow you to adjust a set activation point for vibration as well as a time delay to avoid false triggering from start-up vibration. An alarm signals if the set activation point is exceeded. Plug the included cable into your data collector or programmable logic controller. IP67 rated for protection from dust and water.
Use an optional magnetic base for temporary mounting.
Activation Point | Housing | Power Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Frequency Range, Hz | Current Output | Input Voltage Range | Ht. | Dia. | Temp. Range, °F | Mounting Stud Thread Size | Electrical Connection Type | Industry Designation | Number of Wires | Cord Lg., ft. | Specifications Met | Each | |
1 On (Normally Closed) Switch Starting Position | ||||||||||||||
SPST-NC | ||||||||||||||
0"-1" | 10-1,000 | 4-20 mA | 18V DC-32V DC | 2.9" | 1 1/16" | -10° to 175° | M8 | Plug | M12 | 4 | 16 | ISO 10816, CE Marked, C-UL Listed, UL Listed | 0000000 | 0000000 |
0"-2" | 10-1,000 | 4-20 mA | 18V DC-32V DC | 2.9" | 1 1/16" | -10° to 175° | M8 | Plug | M12 | 4 | 16 | ISO 10816, CE Marked, C-UL Listed, UL Listed | 0000000 | 000000 |
Get NEMA 4 and IP66 protection from dirt and water. Switch is rated for hazardous locations for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. If vibration or shock exceeds a set activation point, the contacts actuate to either shut down your machine or activate an alarm. Reset the switch with the push of a button. The activation point is adjustable between 0 to 5 gravity units (g) at 0 to 60 Hz.
Activation Point | Switching | Conduit | Mounting Slot | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, g | Frequency Range, Hz | Current, A | Voltage | Temp. Range, °F | Trade Size | Thread Type | Gender | Mounting Fasteners Included | Number of Mounting Holes | Lg. | Wd. | Environmental Rating | Each | |
1 Off (Normally Open) or 1 On (Normally Closed) Switch Starting Position | ||||||||||||||
SPDT | ||||||||||||||
0-5 | 0-60 | 15 | 125V AC 480V AC | -40° to 155° | 3/4 | NPT | Female | No | 4 | 3/4" | 3/8" | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G IP66 NEMA 4 | 0000000 | 0000000 |