Wire Gauge Wire Gauge |
---|
Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
System of Measurement System of Measurement |
---|
|
Inner Insulation Color Inner Insulation Color |
---|
![]() | Black |
![]() | Blue |
![]() | Green |
![]() | Green/Black |
![]() | Green/Yellow |
![]() | Orange |
![]() | Orange/Black |
![]() | Red |
![]() | Red/Black |
![]() | White |
![]() | White/Black |
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Ultra Flexible |
Voltage Voltage |
---|
|
Wire Type Wire Type |
---|
![]() | |
Use For Use For |
---|
|
Current Current |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Specifications Met Specifications Met |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Wire Finish Wire Finish |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Cable

Use this general purpose cable to supply power to equipment.
For technical drawings and 3-D models, click on a part number.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | Per Ft. | |
Stranded Wire—Black Outer Insulation | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
14 | 10 | 14/10 | 10.5 A @ 86° F | 0.88" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 000000 | 00000 |
No-Conduit-Required Continuous-Flex Cable


- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range: 25° to 175° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic, PVC Plastic
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
14 | 10 | 14/10 | 17 A @ 86° F | 0.63" | 5.04" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 |