Wire Gauge Wire Gauge |
---|
System of Measurement System of Measurement |
---|
|
Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Ultra Flexible |
Inner Insulation Color Inner Insulation Color |
---|
![]() | Black |
![]() | Blue |
![]() | Green |
![]() | Green/Black |
![]() | Green/Yellow |
![]() | Orange |
![]() | Orange/Black |
![]() | Red |
![]() | Red/Black |
![]() | White |
![]() | White/Black |
Voltage Voltage |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Wire Type Wire Type |
---|
![]() | |
Use For Use For |
---|
|
Current Current |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Specifications Met Specifications Met |
---|
|
Wire Finish Wire Finish |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Cable

Use this general purpose cable to supply power to equipment.
For technical drawings and 3-D models, click on a part number.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
16 | 10 | 16/10 | 5 A @ 86° F | 0.62" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 |
No-Conduit-Required Continuous-Flex Cable


- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range: 25° to 175° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic, PVC Plastic
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
16 | 10 | 16/10 | 12 A @ 86° F | 0.56" | 4.48" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 |
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
20,000V DC/28,000V AC | ||||||||||||||
16 | 10 | 16/10 | 26 A @ 86° F | 1.14" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 000000 | 000000 |