Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
![]() | Double Shielded |
Wire Gauge Wire Gauge |
---|
System of Measurement System of Measurement |
---|
|
Wire Type Wire Type |
---|
![]() | |
Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Ultra Flexible |
![]() |
Flexible |
Inner Insulation Marking Inner Insulation Marking |
---|
|
Voltage Voltage |
---|
|
|
Wire Finish Wire Finish |
---|
|
Wire Material Wire Material |
---|
|
Use For Use For |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Wire and Cable
More
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
12,000V DC/17,000V AC | ||||||||||||||
24 | 10 | 24/10 | 8 A @ 86° F | 0.62" | 0.09" | 1" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.

- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: PVC Plastic
Ribbon Cable

- Use For: Automation, Data, Panel and Equipment (Hook-Up)
- Ultra Flexible
- Temperature Range: 0° to 175° F
- Insulation: PVC Plastic
Often used in electronic prototyping or in the interior of computers, this flat cable is ultra flexible with small-gauge wires so it fits in tight spaces. Unlike standard flat control cable, the wires are bonded together without an overall insulation, so they can be easily separated for installation. Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Continuous-Flex Data Communication Cable

- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, they release minimal particles into the air. All are CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | OD | Bend Radius | Outer Insulation Color | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire with PVC Plastic Insulation | |||||||||||
300V AC | |||||||||||
24 | 10 | 24/10 | 0.33" | 2.48" | Gray | ISO Class 1 | UL Recognized Component, CE Marked, C-UL Recognized Component, Flame Rated VW-1, NFPA 79 | 0000000 | 00000 | 00000 |
Data Communication Cable

- Use For: Data, Interference Shielding
- Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Use this cable for complex data and signal transmission, such as in high-speed computers. It has braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices. The industry designation is CM and CMG, so it’s approved for in-wall installation and has flame-resistant insulation. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||
300V AC | |||||||||||||
24 | 10 | 24/10 | 10 | 12.5 pF | 0.31" | CM, CMG | Gray | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | Uninsulated Ground Wire | 00000000 | 00000 | 00000 |
Twisted-Pair Data Communication Cable

- Use For: Data, Interference Shielding
- Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
This cable has twisted pairs of wires that cancel signal interference from multiple transmission lines, as well as foil and braid shielding over the entire cable. It's often used to transmit data in high speed computers near variable-frequency drive motors, where voltage fluctuations and current spikes can distort signals. The industry designation is CM and CMG, so it’s approved for in-wall installation and has flame-resistant insulation. The uninsulated ground wire is not counted in the number of wires.