Wire Gauge Wire Gauge |
---|
Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
![]() | Double Shielded |
System of Measurement System of Measurement |
---|
|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Flexible |
Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
Voltage Voltage |
---|
|
|
Wire Finish Wire Finish |
---|
|
Wire Material Wire Material |
---|
|
Wire Application Wire Application |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
12,000V DC/17,000V AC | ||||||||||||||
24 | 8 | 24/8 | 8 A @ 86° F | 0.5" | 0.09" | 1" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Servomotor Continuous-Flex Cable

- Use For: Automation, Continuous Motion, Interference Shielding, Motors
- Continuous Flex
- Temperature Range: -40° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: Polypropylene Plastic
Connect servocontrollers and servomotors in automated equipment and on assembly lines. This cable withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion and oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Cable with signal wires is also known as feedback cable. It sends and receives signals between a servomotor and a PLC.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.

No. of Wires | Wire Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Shielded—30V AC/45V DC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8 | 24 | 24/8 | 1.4 A @ 86° F | 0.29" | 1.87" | Green | Blue, Brown, Gray, Green, Pink, Red, White, Yellow | UL Recognized Component, Flame Rated VW-1 | 0000000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.

- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: PVC Plastic
Continuous-Flex Data Communication Cable

- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, they release minimal particles into the air. All are CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | OD | Bend Radius | Outer Insulation Color | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire with PVC Plastic Insulation | |||||||||||
300V AC | |||||||||||
24 | 8 | 24/8 | 0.31" | 2.33" | Gray | ISO Class 1 | UL Recognized Component, CE Marked, C-UL Recognized Component, Flame Rated VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire with TPE Rubber Insulation | |||||||||||
300V AC | |||||||||||
24 | 8 | 24/8 | 0.35" | 2.24" | Blue | ISO Class 1 | CE Marked | 0000000 | 0000 | 0000 |
Data Communication Cable

- Use For: Data, Interference Shielding
- Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Use this cable for complex data and signal transmission, such as in high-speed computers. It has braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices. The industry designation is CM and CMG, so it’s approved for in-wall installation and has flame-resistant insulation. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||
300V AC | |||||||||||||
24 | 8 | 24/8 | 10 | 12.5 pF | 0.28" | CM, CMG | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | 00000000 | 00000 | 00000 |
Ethernet Cable

- Use For:
Unshielded: Data; Category 3 can also be used for Telephones
Shielded, Double Shielded: Data, Interference Shielding - Flexible
- Insulation: PVC Plastic
Send data between computers, printers, servers, and switches in an office or workstation. This cable is backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Duct-Rated Ethernet Cable

- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Insulation: PVC Plastic
Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Oil-Resistant Ethernet Cable


- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Max. Temperature: 165° F
- Insulation: PVC Plastic
Transmit data in rough industrial applications. An additive in the PVC insulation gives this cable excellent resistance to oil and UV light. It’s backward compatible so it works in networks that meet the same or a lower category.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Duct-Rated Oil-Resistant Ethernet Cable

- Use For: Data
- Flexible
- Max. Temperature: 300° F
- Insulation: FEP Plastic
Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.