Wire Gauge Wire Gauge |
---|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Ultra Flexible |
Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
System of Measurement System of Measurement |
---|
|
Wire Type Wire Type |
---|
![]() | |
Current Current |
---|
|
Voltage Voltage |
---|
|
Wire Material Wire Material |
---|
|
Wire Finish Wire Finish |
---|
|
Specifications Met Specifications Met |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Minimum Temperature Minimum Temperature |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Wire and Cable
More
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
12,000V DC/17,000V AC | ||||||||||||||
26 | 10 | 26/10 | 6 A @ 86° F | 0.57" | 0.09" | 0.9" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Ribbon Cable

- Use For: Automation, Data, Panel and Equipment (Hook-Up)
- Ultra Flexible
- Temperature Range: 0° to 175° F
- Insulation: PVC Plastic
Often used in electronic prototyping or in the interior of computers, this flat cable is ultra flexible with small-gauge wires so it fits in tight spaces. Unlike standard flat control cable, the wires are bonded together without an overall insulation, so they can be easily separated for installation. Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.