For Use With For Use With |
---|
|
Valve Type Valve Type |
---|
|
Core Material Core Material |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Hose Connection Thread Type Hose ConnectionThread Type |
---|
|
Manifold Type Manifold Type |
---|
|
Tap into refrigerant lines to drain and fill your system. These valves are self-piercing and can be installed without drilling a hole into the line. A valve cap is included.
Valve Port Thread | Core | ||||||||
---|---|---|---|---|---|---|---|---|---|
For Tube OD | Lg. | Dia. | Type | Gender | Dia. | Material | Body Material | Each | |
1/4" | 1 1/2" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 00000 |
5/16" | 1 1/2" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 0000 |
3/8" | 1 1/2" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 0000 |
1/2" | 1 1/2" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 0000 |
5/8" | 1 1/2" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 0000 |
3/4" | 1 1/2" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 00000 |
1/4" SAE Brass Caps (Pkg. of 10) | 0000000 | Pkg. | 00000 |
Tap into refrigerant lines to drain and fill your system. These valves are self-piercing and can be installed without drilling a hole into the line. A valve cap is included.
Style 2 has a removable core to provide unobstructed flow for your refrigerant once the core is removed.
Replacement cores and core kits are sold separately. The kits include a core remover with four valve cores.
Valves | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Valve Port Thread | Core | Replacement Cores | Core Kits | ||||||||||||
Style | For Tube OD | Lg. | Dia. | Type | Gender | Dia. | Material | Body Material | Each | Pkg. Qty. | Pkg. | Each | |||
1 | 1/4", 5/16", 3/8" | 1 3/4" | 1/4" | SAE Flared | Male | __ | __ | Zinc | 0000000 | 00000 | __ | 000000 | 00 | 000000 | 00 |
1 | 1/2", 5/8" | 2 1/8" | 1/4" | SAE Flared | Male | __ | __ | Zinc | 0000000 | 0000 | __ | 000000 | 00 | 000000 | 00 |
2 | 1/4", 5/16", 3/8" | 1 1/2" | 1/4" | SAE Flared | Male | 1/4" | Stainless Steel | Zinc | 0000000 | 0000 | 6 | 0000000 | 00000 | 0000000 | 000000 |
2 | 1/2", 5/8" | 1 13/16" | 1/4" | SAE Flared | Male | 1/4" | Stainless Steel | Zinc | 0000000 | 00000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
1/4" SAE Brass Caps (Pkg. of 10) | 0000000 | Pkg. | 00000 |
For hard-to-reach spaces, these valves are longer than standard air conditioner service valves. They tap into refrigerant lines to drain and fill your system. All have a removable core to provide unobstructed flow for your refrigerant once the core is removed. A valve cap is included.
Replacement cores and core kits are sold separately. The kits include a core remover with four valve cores.
Valves | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Valve Port Thread | Core | Replacement Cores | Core Kits | ||||||||||||
For Tube OD | Lg. | Dia. | Type | Gender | Dia. | Material | Body Material | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | Each | |||
1/8" | 3" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 00000 | 6 | 0000000 | 00000 | 0000000 | 000000 |
1/4" | 2 15/16" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 0000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
5/16" | 2 13/16" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 0000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
3/8" | 2 13/16" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 0000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
1/2" | 2 1/8" | 1/4" | SAE Flared | Male | 1/4" | Nickel-Plated Brass | Brass | 3 | 0000000 | 00000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
1/4" SAE Brass Caps (Pkg. of 10) | 0000000 | Pkg. | 00000 |
Monitor refrigerant pressure with analog gauges when servicing air conditioning systems. All manifolds have double O-ring piston valves. Manifolds with sight glass allow you to view liquid levels.
Replacement gauges are sold separately.
Optional gauge cover sets (sold separately) include one blue and one red gauge cover. They are not for use with the manifolds for R-410A refrigerant.
Hose | Gauge | |||||||
---|---|---|---|---|---|---|---|---|
For Refrigerant Number | Valve Material | Connection | Lg., ft. | Dia. | Color | Includes | Each | |
Two Valve | ||||||||
R-134a | Brass | 1/2 Acme × 1/4 SAE Flared × 1/4 SAE Flared | 5 | 2 1/2" | One Blue and One Red | __ | 0000000 | 0000000 |
R-134a, R-404A, R-407C | Aluminum | 1/4 SAE Flared × 1/4 SAE Flared × 1/4 SAE Flared | 5 | 3 1/8" | One Blue and One Red | Sight Glass | 0000000 | 000000 |
R-22, R-404A, R-410A | Aluminum | 1/4 SAE Flared × 1/4 SAE Flared × 1/4 SAE Flared | 5 | 3 1/8" | One Blue and One Red | Sight Glass | 0000000 | 000000 |
R-410A | Brass | 1/4 SAE Flared × 1/4 SAE Flared × 1/4 SAE Flared | 5 | 2 1/2" | One Blue and One Red | __ | 0000000 | 000000 |
Four Valve | ||||||||
R-134a, R-404A, R-407C | Aluminum | 1/4 SAE Flared × 1/4 SAE Flared × 1/4 SAE Flared × 3/8 SAE Flared | 5 | 3 1/8" | One Blue and One Red | Sight Glass | 0000000 | 000000 |
R-22, R-404A, R-410A | Aluminum | 1/4 SAE Flared × 1/4 SAE Flared × 1/4 SAE Flared × 3/8 SAE Flared | 5 | 3 1/8" | One Blue and One Red | Sight Glass | 0000000 | 000000 |
For Manifold Type | Includes | Set | |
Two Valve, Four Valve | One Blue Cover, One Red Cover | 0000000 | 000000 |
Monitor refrigerant pressure on an LCD when servicing air conditioning systems. This manifold automatically calculates how much refrigerant is needed in a system based on measurements taken with its thermocouples.
Display | |||||||
---|---|---|---|---|---|---|---|
For Refrigerant Number | Valve Material | Hose Connection | Type | Size | Batteries Included | Each | |
Three Valve | |||||||
R-134a, R-22, R-404A, R-410A | Brass | 1/4 NPT Flared × 1/4 NPT Flared × 1/4 NPT Flared | Digital | 5" | Yes | 0000000 | 0000000 |
Dispense programmed amounts of refrigerant. This scale weighs refrigerant cylinders to dispense the correct amount. It has an LCD to display weight in lbs. and kg.
Each comb fits two different fin spacings. Use them to clean as well as straighten fins on condensers and evaporators to keep cold air flowing.
Kits include a handle and six interchangeable heads to fit a variety of fin spacings. Use them to clean as well as straighten fins on condensers and evaporators to keep cold air flowing.
Additional heads are sold separately.
Tablets gradually dissolve, preventing deposits from developing on the pan. They keep your condensate pan clean and odor-free. Use one tablet per ton of system capacity each month.
For Max. Air Conditioner Cooling Cap., Btu/hr. | Number of Tablets | Useful Life | Each | |
180,000 | 200 | 1 Month | 0000000 | 000000 |
Brush Lg. | Overall Lg. | Bristle Material | Handle Material | Each | |
20" | 26" | Polypropylene Plastic | Thermoplastic Rubber | 0000000 | 00000 |
Optional fill-level switch (sold separately) can be added to the 30- and 50-lb. cap. cylinders to prevent overfilling.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., lbs. | Max. Pressure, psi | Dia. | Ht. | For Refrigerant Type | For Refrigerant Number | Air Tank Valve Opening | Valve Shape | Color | Useful Life | Specifications Met | Each | |
1/4 SAE Flared Hose Connection | ||||||||||||
15 | 400 | 8" | 13" | CFC (chlorofluorocarbon) HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-22, R-404A, R-407C, R-502 | __ | Wye | Gray and Yellow | Reusable | D.O.T. 4BA | 00000000 | 0000000 |
30 | 350 | 9" | 18" | CFC (chlorofluorocarbon) HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-22, R-404A, R-407C, R-502 | 1/4" | Wye | Gray and Yellow | Reusable | D.O.T. 4BA | 00000000 | 000000 |
30 | 400 | 9" | 19" | CFC (chlorofluorocarbon) HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-134a, R-22, R-404A, R-407C, R-502 | __ | Wye | Gray and Yellow | Reusable | D.O.T. 4BA | 00000000 | 000000 |
50 | 350 | 12" | 19" | CFC (chlorofluorocarbon) HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-134a, R-22, R-404A, R-407C, R-502 | 1/4" | Wye | Gray and Yellow | Reusable | D.O.T. 4BA | 00000000 | 000000 |
50 | 400 | 12" | 19" | CFC (chlorofluorocarbon) HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-22, R-404A, R-407C, R-502 | 1/4" | Wye | Gray and Yellow | Reusable | D.O.T. 4BA | 00000000 | 000000 |
1/2 ACME Hose Connection | ||||||||||||
50 | 400 | 12" | 19" | CFC (chlorofluorocarbon) HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-22, R-404A, R-407C, R-502 | 1/4" | Wye | Blue | Reusable | D.O.T. 4BA | 00000000 | 000000 |
Optional Fill Level Switch for 30- and 50-lb. Cap. Cylinders | 00000000 | Each | 000000 |
Remove moisture and contaminants from your system to prevent corrosion and maintain efficient operation. Dryers contain desiccants. Braze them in place with the copper connections. Note: Maximum air conditioner cooling capacity is based on use with R-22 refrigerant.
Two-way liquid-line filter dryer allows flow through the dryer in either direction without allowing the escape of contaminants already filtered out.
For Line Type | Copper Tube Size | For Max. Air Conditioner Cooling Cap., Btu/hr. | For Refrigerant Type | For Refrigerant Number | Removes Particle Size Down To, microns | Each | |
Liquid | 3/8 | 72,000 | HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-134a, R-22, R-404A, R-407C, R-410A, R-502, R-507 | 25 | 0000000 | 000000 |
Two-Way Liquid | 3/8 | 66,000 | HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-134a, R-22, R-404A, R-407C, R-410A, R-502, R-507 | 25 | 0000000 | 00000 |
Suction | 5/8 | 60,000 | HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-134a, R-22, R-404A, R-407C, R-410A, R-502, R-507 | 25 | 0000000 | 00000 |
Suction | 7/8 | 84,000 | HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-134a, R-22, R-404A, R-407C, R-410A, R-502, R-507 | 25 | 0000000 | 00000 |
Pump liquid and vapor refrigerant out of a system and into a refrigerant cylinder (sold separately). After use, switch to purge mode to expel excess refrigerant from unit.
Hose Connection | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Refrigerant Type | For Refrigerant Number | Thread Size | Thread Type | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Compressor Lubrication | Each | |
120V AC—Three Prong Plug | |||||||||||
CFC (chlorofluorocarbon) HCFC (hydrochlorofluorocarbon) HFC (hydrofluorocarbon) | R-12, R-134a, R-22, R-404A, R-407C, R-502 | 1/4 | SAE Flared | 13" | 12" | 19" | 5 | Plastic | Oilless | 0000000 | 000000000 |
Use hose to charge and test your air conditioning units.
Thread Size | ID | OD | Max. Pressure | Choose a Color | Each | |
3-ft. Lengths | ||||||
---|---|---|---|---|---|---|
Brass Threaded UNF Female × Brass Threaded UNF Female | ||||||
3/8" × 3/8" | 5/16" | 5/8" | 600 psi @ 72° F | Black | 0000000 | 000000 |
Brass Threaded UNF Female × Brass 45° Flared UNF Female | ||||||
1/4" × 1/4" | 3/16" | 1/2" | 800 psi @ 72° F | 000000 | 00000 | |
5-ft. Lengths | ||||||
Brass Threaded UNF Female × Brass 45° Flared UNF Female | ||||||
1/4" × 1/4" | 3/16" | 1/2" | 800 psi @ 72° F | 000000 | 00000 | |
6-ft. Lengths | ||||||
Brass Threaded UNF Female × Brass Threaded UNF Female | ||||||
3/8" × 3/8" | 5/16" | 5/8" | 600 psi @ 72° F | Black | 0000000 | 00000 |
Brass Threaded UNF Female × Brass 45° Flared UNF Female | ||||||
1/4" × 1/4" | 3/16" | 1/2" | 800 psi @ 72° F | 000000 | 00000 | |
Brass Threaded UNF Female × Brass 45° Flared Ball Valve UNF Female | ||||||
1/4" × 7/16" | 3/16" | 1/2" | 800 psi @ 72° F | 0000000 | 00000 |
Each hose is a different color so you can differentiate your lines.
Thread Size | ID | OD | Max. Pressure | Each | |
3-ft. Lengths | |||||
---|---|---|---|---|---|
Brass Threaded UNF Female × Brass 45° Flared UNF Female | |||||
1/4" × 1/4" | 3/16" | 1/2" | 800 psi @ 72° F | 0000000 | 000000 |
5-ft. Lengths | |||||
Brass Threaded UNF Female × Brass 45° Flared UNF Female | |||||
1/4" × 1/4" | 3/16" | 1/2" | 800 psi @ 72° F | 0000000 | 00000 |
6-ft. Lengths | |||||
Brass Threaded UNF Female × Brass 45° Flared UNF Female | |||||
1/4" × 1/4" | 3/16" | 1/2" | 800 psi @ 72° F | 0000000 | 00000 |
Brass Threaded UNF Female × Brass 45° Flared Ball Valve UNF Female | |||||
1/4" × 7/16" | 3/16" | 1/2" | 800 psi @ 72° F | 0000000 | 000000 |
Spray on to clean without rinsing. Use these cleaners to remove dirt, oil, and contaminants from air conditioner coils. They are NSF registered P1 for use in food-processing environments.
Container | ||||||||
---|---|---|---|---|---|---|---|---|
Type | Size, oz. | Composition | Harshness | For Use On | For Removing | Specifications Met | Each | |
Liquid | ||||||||
Aerosol Can | 18 | Water Based | Harsh | Aluminum, Brass, Bronze, Copper, Galvanized Steel, Iron, Stainless Steel, Steel | Dirt, Grease/Oil, Wax | NSF Registered P1 | 00000000 | 000000 |
Brush or spray on; then rinse off. These cleaners contain sodium hydroxide for tough jobs. Use them to remove dirt, oil, and contaminants from air conditioner coils.
Spray gun is sold separately. Add cleaner to the included bottle and connect to a garden hose.
Container | |||||||
---|---|---|---|---|---|---|---|
Type | Size | Composition | Harshness | For Use On | For Removing | Each | |
Liquid Concentrate | |||||||
Bottle | 32 oz. | Water Based | Harsh | Aluminum, Brass, Bronze, Copper, Galvanized Steel, Iron, Stainless Steel, Steel | Dirt, Grease/Oil, Wax | 00000000 | 000000 |
Pail | 5 gal. | Water Based | Harsh | Aluminum, Brass, Bronze, Copper, Galvanized Steel, Iron, Stainless Steel, Steel | Dirt, Grease/Oil, Wax | 00000000 | 000000 |
Spray Guns with Two Quart Bottle | 00000000 | Each | 0000000 |
Prevent condensation from forming on refrigeration and air conditioning lines and cold-water piping. These coatings adhere to metal, PVC, and CPVC.