For Use On For Use On |
---|
Container Type Container Type |
---|
![]() | ![]() |
Can | Aerosol Can |
![]() | ![]() |
Pail | Bottle |
Appearance Appearance |
---|
|
Type Type |
---|
|
Composition Composition |
---|
|
Approximate Coverage @ Thickness Approximate Coverage@ Thickness |
---|
Approximate Coverage Approximate Coverage |
---|
|
For Topcoat Composition For Topcoat Composition |
---|
|
More
Longer-lasting than antislip tape, these coatings contain grit to provide traction. They’re good for areas with pedestrian traffic.
Water-based epoxy coatings are clear and can be applied over nearly any surface, even old coatings, without altering their appearance. These two-part coatings come with a mixer that attaches to a hand-held drill and a roller cover to apply them once mixed. The size listed is the combined total of the two parts.
Apply acrylic coatings with a roller or sprayer. Apply gallon-sized water-based coatings with a roller. Apply gallon-sized solvent-based coatings with a notched trowel, sprayer, or a roller cover for thick coatings (sold separately).
Dry Time | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Size | Composition | Touch | O'all | Approx. Coverage @ Thick. | Approx. Coverage, sq. ft. | Mix Ratio | Application Time After Mixing, min. | For Use On | Primer Required For Use On | Includes | Choose a Color (Appearance) | Each | |
Epoxy—Aerosol Can | |||||||||||||
12 oz. | Solvent Based | 20 min. | 24 hrs. | 15 sq. ft. @ 1 mil | __ | __ | __ | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Iron, Galvanized Iron, Galvanized Steel, Fiberglass, Masonry, Concrete, Stone, Asphalt, Wood | __ | __ | 00000000 | 000000 | |
Epoxy—Can | |||||||||||||
1 gal. | Water Based | 27 min. | 30 min. | 185 sq. ft. @ 38 mil | __ | 4:1 | 25 | Aluminum, Brass, Copper, Steel, Stainless Steel, Galvanized Iron, Galvanized Steel, Plastic, Rubber, Ceramic, Glass, Masonry, Concrete, Stone, Asphalt, Drywall | __ | Mixer, Roller Cover | Clear (Gloss) | 0000000 | 000000 |
1 gal. | Solvent Based | 12 hrs. | 3 days | __ | 50 | __ | __ | Aluminum, Steel, Iron, Fiberglass, Concrete, Wood | Aluminum, Steel, Iron, Concrete, Wood | __ | 00000000 | 000000 | |
Acrylic—Can | |||||||||||||
1 gal. | Water Based | 4 hrs. | 24 hrs. | __ | 70 | __ | __ | Steel, Iron, Concrete, Wood | Steel, Iron, Concrete, Wood | __ | 0000000 | 00000 |
Roller Cover for Solvent-Based Coatings | 0000000 | Each | 00000 |
These high-traction antislip coatings have zero VOCs and are low odor. They contain grit to provide traction for pedestrian, cart, and hand-truck traffic. Apply with a roller. The size listed is the combined total of the two parts.
Container Size, gal. | Composition | O'all Dry Time, hrs. | Approximate Coverage @ Thickness | Mix Ratio | Application Time After Mixing, min. | Max. Temp., °F | Application Temp. Range, °F | Specifications Met | For Use On | Choose a Color (Appearance) | Each | |
Epoxy | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/2 | Water Based | 48 | 50 sq. ft. @ 30 mil | 3:1 | 45 | 300° | 50° to 100° | ADA Standards, ASTM Requirements, OSHA Standards | Aluminum, Steel, Iron, Concrete, Wood | 0000000 | 000000 | |
1 | Water Based | 48 | 50 sq. ft. @ 30 mil | 3:1 | 45 | 300° | 50° to 100° | ADA Standards, ASTM Requirements, OSHA Standards | Aluminum, Steel, Iron, Concrete, Wood | 0000000 | 00000 |
These provide the highest traction and impact resistance of our antislip coatings. Longer-lasting than antislip tape, these coatings contain grit to provide traction. Apply with a roller. The resin and hardener come in separate containers that can be mixed in the pail. The size listed is the combined total of the two parts. They cannot be sold to the regions listed because they exceed local regulatory limits on VOCs (volatile organic compounds).
Coatings that meet MIL-PRF 24667C Type 1 are our most wear and impact resistant. They can also be applied with a notched trowel.
Dry Time | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Touch, hrs. | O'all, days | Approximate Coverage @ Thickness | Application Time After Mixing, hrs. | Max. Temp., °F | Application Temp. Range, °F | Specifications Met | For Use On | Primer Required For Use On | Color (Appearance) | Cannot Be Sold To | Each | |
Epoxy—Can | ||||||||||||||
1 | Solvent Based | 24 | 4 | 25 sq. ft. @ 2 mil | 8 | 160° | 40° to 100° | MIL-PRF 24667C Type 2, Composition G, MIL-PRF 24667C Type 4, Composition G | Aluminum, Steel, Iron, Concrete, Wood | Aluminum, Steel, Iron, Concrete, Wood | Dark Gray (Flat) | Los Angeles County, CA, Orange County, CA, Riverside County, CA, San Bernardino County, CA | 0000000 | 0000000 |
Epoxy—Pail | ||||||||||||||
5 | Solvent Based | 24 | 4 | 125 sq. ft. @ 2 mil | 4 | 160° | 40° to 100° | MIL-PRF 24667C Type 1, Composition G, MIL-PRF 24667C Type 2, Composition G | Aluminum, Steel, Iron, Concrete, Wood | Aluminum, Steel, Iron, Concrete, Wood | Dark Gray (Flat) | Los Angeles County, CA, Orange County, CA, Riverside County, CA, San Bernardino County, CA | 0000000 | 000000 |
5 | Solvent Based | 24 | 4 | 125 sq. ft. @ 2 mil | 8 | 160° | 40° to 100° | MIL-PRF 24667C Type 2, Composition G, MIL-PRF 24667C Type 4, Composition G | Aluminum, Steel, Iron, Concrete, Wood | Aluminum, Steel, Iron, Concrete, Wood | Dark Gray (Flat) | Los Angeles County, CA, Orange County, CA, Riverside County, CA, San Bernardino County, CA | 0000000 | 000000 |
Designed for use in areas with heavy vehicular traffic, these coatings are highly resistant to wear. They contain grit to provide traction to your surface. Apply with a notched trowel, roller, or sprayer. The size listed is the combined total of the two parts. They cannot be sold to the regions listed because they exceed local regulatory limits on VOCs (volatile organic compounds).
Coatings in a pail have a resin and a hardener in separate containers that can be mixed in the pail.
Dry Time | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Touch, hrs. | O'all, days | Approximate Coverage @ Thickness | Application Time After Mixing, hrs. | Max. Temp., °F | Application Temp. Range, °F | Specifications Met | For Use On | Cannot Be Sold To | Choose a Color (Appearance) | Each | |
Epoxy—Can | |||||||||||||
1 | Solvent Based | 12 | 3 | 40 sq. ft. @ 2 mil | 4 | 160° | 50° to 130° | ADA Standards, ASTM Requirements, OSHA Standards | Aluminum, Steel, Iron, Fiberglass, Concrete, Wood | Los Angeles County, CA, Orange County, CA, Riverside County, CA, San Bernardino County, CA | 0000000 | 0000000 | |
Epoxy—Pail | |||||||||||||
5 | Solvent Based | 12 | 3 | 40 sq. ft. @ 2 mil | 4 | 160° | 50° to 130° | ADA Standards, ASTM Requirements, OSHA Standards | Aluminum, Steel, Iron, Fiberglass, Concrete, Wood | Los Angeles County, CA, Orange County, CA, Riverside County, CA, San Bernardino County, CA | 0000000 | 000000 |
Grit in these coatings provides traction and fills hairline cracks. Coatings form a weather- and water-resistant seal to protect and revitalize asphalt surfaces. Apply with a squeegee or brush.
Dry Time | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Touch, hrs. | Overall, hrs. | Approx. Coverage @ Thick. | Max. Temp., °F | Application Temp. Range, °F | For Use On | Color | Each | |
4 3/4 | Oil Based | 2 | 48 | 300 sq. ft. @ 3 mm | 90° | 55° to 90° | Asphalt | Black | 00000000 | 000000 |
Consisting of small, spherical particles, add these to water- or solvent-based floor coatings to create a slip-resistant surface that’s easier to clean than sand-textured surfaces. Additives won’t change the coating’s color.
Use 3.2 oz. bottle with one gallon of floor coating. Use 16 oz. bottle with five gallons of floor coating.
Use these primers on your surface before antislip coatings to maximize longevity. They do not contain grit. Apply with a brush, roller, or sprayer. The size listed is the combined total of the two parts. They cannot be sold to the regions listed because they exceed local regulatory limits on VOCs (volatile organic compounds).
Dry Time | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Touch, min. | Overall, hrs. | Approx. Coverage @ Thick. | Application Time After Mixing, hrs. | Max. Temp., °F | For Topcoat Composition | For Use On | Color | Cannot Be Sold To | Each | |
1 | Solvent Based | 60 | 12 | 270 sq. ft. @ 4 mil | 4 | 160° | Solvent Based | Aluminum, Steel, Iron | Gray | Los Angeles County, CA, Orange County, CA, Riverside County, CA, San Bernardino County, CA | 0000000 | 000000 |
These thin primers penetrate deeply into concrete floors to create a hard surface that can then be coated with any urethane or epoxy coating. Primers resist abrasion and chemicals, such as mild acids, alkalies, salt, and fuel. Apply with a roller. The size listed is the combined total of the two parts.
Mfr. Model | Dry Time | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | No. | Container Size, gal. | Composition | Touch, hrs. | Overall, hrs. | Approx. Coverage @ Thick. | Max. Temp., °F | Application Temp. Range, °F | For Topcoat Composition | For Use On | Color | Each | |
Loctite® Primers | |||||||||||||
Fixmaster Epoxy | PC 7641 | 1 | Water Based | 2 | 6 | 250 sq. ft. @ 2 mil | 180° | 50° to 120° | Solvent Based, Water Based | Ceramic, Concrete, Stone, Wood, Plaster | Clear | 0000000 | 0000000 |
Use these primers on concrete floors before antislip coatings to maximize longevity. They do not contain grit. Apply with a brush or roller. The size listed is the combined total of the two parts.
Container Size, oz. | Composition | Approx. Coverage @ Thick. | Application Time After Mixing, hrs. | Color | Each | |
96 | Solvent Based | 200 sq. in. @ 2 mil | 1 | Amber | 0000000 | 0000000 |
Also known as block filler, these primers fill cracks and smooth surface irregularities. Use them to prepare concrete floors to extend the life of paint and coatings. Apply with a brush, roller, or sprayer.
Dry Time | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Touch, min. | Overall, hrs. | Approx. Coverage @ Thick. | Max. Temp., °F | Application Temp. Range, °F | For Topcoat Composition | For Use On | Color | Each | |
1 | Water Based | 60 | 4 | 80 sq. ft. @ 8 mil | 150° | 50° to 90° | Solvent Based, Water Based | Masonry, Concrete | White | 0000000 | 000000 |