Outer Jacket | Inner Insulation | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | OD | Material | Color | Material | Color | Temp. Range, ° F | Cable Designation | Certification | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | |||
Solid Wire | ||||||||||||||||||
150V AC/150V DC | ||||||||||||||||||
| 20 | 2 | 20/2 | 0.11" | PVC | Brown | Polyethylene | Red, White | 0 to 140 | CL2 | ETL Listed | 8278T11 | 00000 | 000000 | 000000 | 000000 | 000000 | ||
| 20 | 3 | 20/3 | 0.12" | PVC | Brown | Polyethylene | Green, Red, White | 0 to 140 | CL2 | ETL Listed | 8278T12 | 0000 | 00000 | 00000 | 00000 | — | ||
| 20 | 4 | 20/4 | 0.13" | PVC | Brown | Polyethylene | Blue, Green, Red, White | 0 to 140 | CL2 | ETL Listed | 8278T13 | 00000 | 00000 | 00000 | 00000 | 00000 | ||
| 20 | 5 | 20/5 | 0.15" | PVC | Brown | Polyethylene | Blue, Green, Red, White, Yellow | 0 to 140 | CL2 | ETL Listed | 8278T14 | 00000 | 00000 | 00000 | 00000 | 00000 | ||
| 20 | 6 | 20/6 | 0.16" | PVC | Brown | Polyethylene | Blue, Brown, Green, Red, White, Yellow | 0 to 140 | CL2 | ETL Listed | 8278T15 | 00000 | 00000 | 00000 | 00000 | 000000 | ||
| 20 | 8 | 20/8 | 0.17" | PVC | Brown | Polyethylene | Black, Blue, Brown, Green, Orange, Red, White, Yellow | 0 to 140 | CL2 | ETL Listed | 8278T16 | 00000 | 00000 | 00000 | 00000 | 000000 | ||
| 18 | 2 | 18/2 | 0.13" | PVC | Brown | Polyethylene | Red, White | 0 to 140 | CL2 | ETL Listed | 8278T21 | 0000 | 00000 | 00000 | 00000 | 00000 | ||
| 18 | 3 | 18/3 | 0.14" | PVC | Brown | Polyethylene | Green, Red, White | 0 to 140 | CL2 | ETL Listed | 8278T22 | 00000 | 00000 | 00000 | 00000 | 00000 | ||
| 18 | 4 | 18/4 | 0.15" | PVC | Brown | Polyethylene | Blue, Green, Red, White | 0 to 140 | CL2 | ETL Listed | 8278T23 | 00000 | 00000 | 00000 | 00000 | 000000 | ||
| 18 | 5 | 18/5 | 0.17" | PVC | Brown | Polyethylene | Blue, Green, Red, White, Yellow | 0 to 140 | CL2 | ETL Listed | 8278T24 | 00000 | 00000 | 00000 | 00000 | 000000 | ||
| 18 | 6 | 18/6 | 0.19" | PVC | Brown | Polyethylene | Blue, Brown, Green, Red, White, Yellow | 0 to 140 | CL2 | ETL Listed | 8278T25 | 00000 | 00000 | 00000 | 00000 | 000000 | ||
| 18 | 8 | 18/8 | 0.2" | PVC | Brown | Polyethylene | Black, Blue, Brown, Green, Orange, Red, White, Yellow | 0 to 140 | CL2 | ETL Listed | 8278T26 | 00000 | 00000 | 00000 | 00000 | 000000 | ||
Ribbon Cable
Outer Jacket | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | Current @ Temp. | Wd. | Thk. | Material | Color | Temp. Range, ° F | Certification | Flammability Rating | 10 ft. Long | 25 ft. Long | |||
Stranded Wire | |||||||||||||||
150V AC | |||||||||||||||
| 26 | 10 | 26/10 | 1 amp @ 86° F | 0.39" | 0.04" | PVC | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | 0 to 175 | UL Recognized Component | UL 2556 VW-1 | 2674N21 | 000000 | 0000000 | ||
| 26 | 15 | 26/15 | 1 amp @ 86° F | 0.59" | 0.04" | PVC | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | 0 to 175 | UL Recognized Component | UL 2556 VW-1 | 2674N22 | 00000 | 000000 | ||
| 24 | 10 | 24/10 | 2.1 amp @ 86° F | 0.44" | 0.04" | PVC | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | 0 to 175 | UL Recognized Component | UL 2556 VW-1 | 2674N23 | 000000 | 000000 | ||
| 24 | 15 | 24/15 | 2.1 amp @ 86° F | 0.66" | 0.04" | PVC | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | 0 to 175 | UL Recognized Component | UL 2556 VW-1 | 2674N24 | 000000 | 000000 | ||
| 22 | 10 | 22/10 | 3.1 amp @ 86° F | 0.51" | 0.05" | PVC | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | 0 to 175 | UL Recognized Component | UL 2556 VW-1 | 2674N25 | 000000 | 000000 | ||
| 22 | 15 | 22/15 | 3.1 amp @ 86° F | 0.77" | 0.05" | PVC | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | 0 to 175 | UL Recognized Component | UL 2556 VW-1 | 2674N26 | 000000 | 000000 | ||
Speaker Cable
Outer Jacket | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | Temp. Range, ° F | Wd. | Thk. | Material | Color | Certification | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | |||
CL2 Stranded Wire | ||||||||||||||||
150V AC/150V DC | ||||||||||||||||
| 14 | 2 | 14/2 | 0 to 140 | 0.38" | 0.18" | PVC | Clear | ETL Listed, C-ETL Listed | 8260T145 | — | — | — | — | 0000000 | ||
| 12 | 2 | 12/2 | 0 to 140 | 0.41" | 0.19" | PVC | Clear | ETL Listed, C-ETL Listed | 8260T15 | 000000 | 000000 | 000000 | 0000000 | 000000 | ||
M16 Connectors
Female Receptacles
![]() |
No. of Poles | Voltage | Current, amp | Wire Connection Method | Mounting Thread Size | Enclosure Rating | Each | ||
|---|---|---|---|---|---|---|---|---|
| 3 | 150V AC/150V DC | 7 | Solder | M18 | IP69K | 8067N25 | 000000 | |
| 4 | 150V AC/150V DC | 7 | Solder | M18 | IP69K | 8067N27 | 00000 | |
| 5 | 150V AC/150V DC | 7 | Solder | M18 | IP69K | 8067N29 | 00000 | |
| 6 | 150V AC/150V DC | 7 | Solder | M18 | IP69K | 8067N31 | 00000 | |
| 7 | 150V AC/150V DC | 7 | Solder | M18 | IP69K | 8067N33 | 00000 |
Continuous-Flex Lead Wire
Stranded Wire with PVC Outer Jacket