About Safety Ratings for Electrical Testing
More
Fluke Clamp-On Multimeters
Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Jaw Opening | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Display Count | Includes | Each | |
Multimeters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | ||||||||||||
324 | 1.18" | CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | __ | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 0000000 |
355 | 2.3" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 600 | 1,000 | 1% | 2,000 | 2,000 | 10,000 | Alligator Clips, Carrying Case, Test Leads, Test Probes | 00000000 | 00000000 |
374 FC | 1.3" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance | 1,000 | 1,000 | 1% | 600 | 600 | 6,000 | Carrying Case, Test Leads | 00000000 | 000000 |
376 FC | 1.3" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Carrying Case, Flexible Current Loop, Test Leads | 00000000 | 000000 |
381 | 1.34" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads | 00000000 | 000000 |
Multimeters with Calibration Certificate | ||||||||||||
True RMS AC Calculation | ||||||||||||
324 | 1.18" | CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | __ | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 000000 |
374 FC | 1.3" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance | 1,000 | 1,000 | 1% | 600 | 600 | 6,000 | Carrying Case, Test Leads | 00000000 | 000000 |
376 FC | 1.3" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Carrying Case, Flexible Current Loop, Test Leads | 00000000 | 000000 |
381 | 1.34" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads | 00000000 | 00000000 |
Clamp-On Multimeters
Suitable for testing high current, these multimeters have jaws that surround a cable to test without interrupting the circuit. They include test leads to perform other electrical tests.
Average sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors. True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Replacement Test Leads | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Jaw Opening | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Display Count | Includes | Each | Pair | ||
Average Sensing AC Calculation | |||||||||||||
1" | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Voltage, Frequency, Resistance, Temperature | 600 | 600 | 1% | 600 | __ | 4,000 | Carrying Case, Temperature Probe, Test Leads | 0000000 | 0000000 | 0000000 | 000000 |
1.7" | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Voltage, Frequency, Resistance, Temperature | 600 | 600 | 1.5% | 1,000 | __ | 4,000 | Built-In Infrared Temperature Sensor, Carrying Case, Test Leads | 0000000 | 000000 | 0000000 | 00000 |
True RMS AC Calculation | |||||||||||||
1.18" | CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 600 | 600 | 1% | 600 | 600 | 6,000 | Carrying Case, Test Leads | 0000000 | 000000 | 0000000 | 00000 |
1.18" | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 750 | 1,000 | 0.8% | 600 | 600 | 6,000 | Temperature Probe, Test Leads | 0000000 | 000000 | 0000000 | 00000 |
1.7" | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 600 | 600 | 1.5% | 1,000 | 1,000 | 4,000 | Built-In Infrared Temperature Sensor, Carrying Case, Temperature Probe, Test Leads | 0000000 | 000000 | 0000000 | 00000 |
2" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.8% | 1,000 | 1,000 | 6,000 | Carrying Case, Test Leads | 0000000 | 000000 | 0000000 | 00000 |
Analog Clamp-On Multimeters
Measure rapidly changing electrical values more easily than with a digital multimeter. Convenient for taking frequent high current measurements, the meter has jaws that surround a cable to test current without interrupting the circuit. Use the included test leads to perform other electrical tests.
This multimeter is average sensing, so it takes accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Jaw Opening | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Hardware Features | Includes | Size | No. Required | Each | |
Average Sensing AC Calculation | |||||||||||
1.5" | AC Current, AC Voltage, DC Voltage, Resistance | 600 | 60 | 4% | 600 | Overload Protection | Test Leads | AA | 1 | 0000000 | 0000000 |
AA Batteries (Pkg. of 4) | 00000000 | Pkg. | 00000 |
Clamp-On Current Meters
Measure current without interrupting the circuit—jaws surround a cable for testing, making these meters convenient for taking frequent measurements.
These current meters are average sensing, so they take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
Display count is an industry designation and not an actual value. For example, a 2,000-count meter shows numbers up to 1,999. A higher display count means the meter can give a more precise measurement.
Safety Rating | AC Current, A | Current Accuracy | Measures | Jaw Opening | Includes | Display Count | Batteries Included | Each | |
Average Sensing AC Calculation | |||||||||
---|---|---|---|---|---|---|---|---|---|
CAT III, 300V | 0-20, 0-200 | 2-3% | AC Current | 1.25" | Carrying Case | 2,000 | Yes | 0000000 | 0000000 |