    Cut-to-Length Level Sensor Switches for Conductive Liquids

    Image of Product. Front orientation. Level Sensor Switches. Cut-to-Length Level Sensor Switches for Conductive Liquids, 2 Probes.
    Image of Product. Front orientation. Level Sensor Switches. Cut-to-Length Level Sensor Switches for Conductive Liquids, 3 Probes.
    Image of Specification. Front orientation. ZoomedIn view. Relay. Cut-to-Length Level Sensor Switches for Conductive Liquids.

    2 Probes

    3 Probes

    Relay

    Cut the probes on these switches to fit the size of your tank. They’re designed to use the properties of conductive liquid for operation, and actuate when conductive liquid reaches the probes to close the circuit. Do not use in flammable liquids. Mount them vertically through the top of your tank.
    2 Probes—Switches with two probes detect one level change.
    3 Probes—Switches with three probes detect two level changes, so they can activate your equipment when your tank is empty and when it’s full.
    Level Sensor Switches
    Replacement
    Probes
    Probes
    No.
    of
    Lg.
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Probe Material
    Electrical
    Connection
    Includes
    Certification
    Each
    Each
    120V AC Input Voltage
     
    Aluminum Body
    212"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    000000000000000000000000000000
    218"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    0000000000000000000000000000000
    224"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    0000000000000000000000000000000
    236"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    0000000000000000000000000000000
    312"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    0000000000000000000000000000
    318"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    0000000000000000000000000000000
    324"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    0000000000000000000000000000000
    336"2
    NPT
    Male250 psi @ 70° F-40 to 1501 Off or 1 On
    SPDT
    10 amp @ 120V ACPTFE-Coated Stainless SteelScrew TerminalRelayUL Listed, CSA Certified
    0000000000000000000000000000000
     

    Level Sensor Switches for Conductive Liquids

    Image of Product. Front orientation. Contains Annotated. Level Sensor Switches. Level Sensor Switches for Conductive Liquids.
    Designed to use the properties of conductive liquid for operation, these switches actuate when conductive liquid reaches the probes on the tip to close the circuit. They can be used with dirty fluid and liquid with high solid content, but are not for use with flammable liquids. Mount them horizontally or vertically. All are rated NEMA 6 for protection from washdowns.
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Probe Material
    Electrical
    Connection
    Wire Lead
    Lg., ft.
    Enclosure
    Rating
    Each
     
    PPS Body
    3/4
    NPT
    Male1290 psi @ 70° F-10 to 1751 1/2"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads6IP68, NEMA 6
    00000000000000
    3/4
    NPT
    Male1290 psi @ 70° F-10 to 1753"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads6IP68, NEMA 6
    0000000000000
     
    Polypropylene Body
    3/4
    NPT
    Male185 psi @ 70° F-10 to 1401 1/2"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads6IP68, NEMA 6
    0000000000000
    3/4
    NPT
    Male185 psi @ 70° F-10 to 1403"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads6IP68, NEMA 6
    0000000000000
     

    Noncontact Level Sensor Switches for Conductive Liquids

    Measure the level of conductive liquids without drilling a hole in your tank—these switches mount to the outside of the tank and track the capacitance between them and the tank’s contents. Use them on nonconductive plastic or glass wall tanks; they’re not compatible with metal tanks. They automatically adapt to your tank’s wall thickness, making them ready to use. These switches only respond when the liquid reaches the desired level, so foam and residue on the top of the liquid won’t trigger them early. For even more challenging setups, such as those with thick, sticky fluids, or if your tank has walls as thick as 10 mm, you can teach these switches to avoid false detections. All have LED indicators to show their power and output status.
    Made of plastic, their body is chemical resistant and NEMA and IP rated, so it keeps out dust and dirt, as well as drips of oil and jets of hot water. UL listed, C-UL listed, and CE marked, they meet U.S., Canadian, and European Union safety standards.
    Mount these switches directly on your sight glass using their adhesive back or use the included mounting bracket if you’ll need to remove them frequently. They also include foam pads for mounting them using straps around the outside of your tank.
    Level Sensor Switches with Nano M8 4-Pin Connection
    Image of Product. With Nano M8 4-pin Connection. Front orientation. Level Sensor Switches. Noncontact Level Sensor Switches for Conductive Liquids, Level Sensor Switches with Nano M8 4-Pin Connection.
    Image of Specification. Nano M8 4-pin. Front orientation. Nano M8 Connection. Noncontact Level Sensor Switches for Conductive Liquids, 4 Pins.

    With Nano M8 4-pin

    Connection

    Nano

    M8

    4-pin

    Switches with an Nano M8 4-Pin connection have a standard plug that’s easy to connect.
    PNP Signal Output—PNP switches communicate with your system by sending a positive signal.
    Signal
    Output
    Wd.
    Ht.
    Thk.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Enclosure Rating
    Each
    10V DC to 30V DC Input Voltage
     
    Polybutylene/Polycarbonate Body
    PNP5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DCNEMA 4X, NEMA 12, IP68, IP69K, IP66
    00000000000000
    PNP5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DCNEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
     
    Level Sensor Switches with Wire Lead Connection
    Image of Product. With Wire Lead Connection. Front orientation. Level Sensor Switches. Noncontact Level Sensor Switches for Conductive Liquids, Level Sensor Switches with Wire Lead Connection.

    With Wire Lead Connection

    Switches with wire leads need to be hardwired, so use them in applications where you won’t move them often.
    PNP Signal Output—PNP switches communicate with your system by sending a positive signal.
    NPN Signal Output—NPN switches send a negative signal to communicate with your system.
    Signal
    Output
    Wd.
    Ht.
    Thk.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Wire Lead
    Lg., ft.
    Enclosure Rating
    Each
    10V DC to 30V DC Input Voltage
     
    Polybutylene/Polycarbonate Body
    PNP5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    00000000000000
    PNP5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
    NPN5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
    NPN5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
     
    back to top