Micro M12 Screw-Together Ethernet Connectors
Unlike traditional RJ45 connectors found in data centers, these connectors stand up to rugged industrial environments since they tightly thread to devices with M12 connections, sealing out contaminants and resisting shaking loose from vibration. Use them to transfer high-speed data between sensors, switches, computers, IO modules, programmable logic controllers (PLCs), and other equipment. They can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. These connectors are often used with EtherNet/IP, Profinet, and EtherCAT systems. Since they’re shielded, they block signal interference from nearby devices, maintaining their speed and data integrity. Poles and keyways on the face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
When choosing an Ethernet connector, make sure you match or exceed your network’s category industry designation. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
Receptacles thread into a panel or wall, making them best for permanent installations such as control panels or hardwiring into equipment.
Adapters create a transition point between an M12 and RJ45 connection. Use them in panels or walls—your tough threaded connection on one side and your control panel and computer or PLC on the other.
90° elbow connectors run your cord along the side of equipment, so they fit behind machines and in tight spaces.
Connectors with a screw-on wire connection, also known as field wireable connectors, do not require special tools like crimpers or soldering irons to attach to cables. Connectors with a snap-on wire connection pierce the wire’s insulation, which means you don’t need to strip it.
Connectors with polyurethane or TPE insulation resist chemicals, oil, and sunlight for outdoor use. Because they’re flexible, they’re good for jobs with continuous motion, such as robotics.
IP rated connectors keep out dust and can be used in wet areas when mated or capped. IP65 connectors can be lightly rinsed. IP67 connectors can be submerged temporarily. IP69 connectors withstand high-pressure, high temperature washdowns.
Add caps to protect connectors and maintain their IP ratings when not in use.


Housing Thread | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Wire Gauge | For Cable OD | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Each | |
D-Code | ||||||||||||
| 4 | Shielded | 26-22 | 0.18"-0.35" | Category 5 | 100 Mbps | Chrome-Plated Zinc | M12 | 1 | -40° to 185° | IP65, IP67 | 000000 | 000000 |


Housing Thread | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Each | |
3 ft. Lg. Cable Leads | ||||||||||||
D-Code | ||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 0000000 | 000000 |
16 ft. Lg. Cable Leads | ||||||||||||
D-Code | ||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 0000000 | 00000 |

Housing Thread | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Each | |
3 ft. Lg. Cable Leads | ||||||||||||
D-Code | ||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 0000000 | 000000 |
16 ft. Lg. Cable Leads | ||||||||||||
D-Code | ||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 0000000 | 00000 |


Housing Thread | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Cable OD | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Each | |
D-Code | |||||||||||
| 4 | Shielded | 0.2"-0.38" | Category 5E | 100 Mbps | Nickel-Plated Zinc | M12 | 1 | -40° to 185° | IP67 | 0000000 | 000000 |


Housing Thread | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
5 ft. Lg. Cable Leads | |||||||||||||
D-Code | |||||||||||||
| 4 | Shielded | 24 (4) | TPE Rubber | Category 5E | 100 Mbps | Nickel-Plated Brass | M12 | 1 | -10° to 175° | IP67 | UL Recognized Component | 0000000 | 000000 |
16 ft. Lg. Cable Leads | |||||||||||||
D-Code | |||||||||||||
| 4 | Shielded | 24 (4) | TPE Rubber | Category 5E | 100 Mbps | Nickel-Plated Brass | M12 | 1 | -10° to 175° | IP67 | UL Recognized Component | 0000000 | 00000 |


Housing Thread | Mounting | 1ft. Lg. Wire Leads | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Wire Lead Gauge (No. of Wires) | Wire Insulation Material | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Pipe Size | Thread Type | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
D-Code | |||||||||||||||
| 4 | 22 (4) | PVC Plastic | Not Rated | Gray | Anodized Aluminum | M12 | 1 | 0.875" | 1/2 | NPT | -40° to 175° | IP69 | UL Listed, C-UL Listed | 0000000 | 000000 |


Housing Thread | Mounting | 1ft. Lg. Wire Leads | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Wire Lead Gauge (No. of Wires) | Wire Insulation Material | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Pipe Size | Thread Type | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
D-Code | |||||||||||||||
| 4 | 22 (4) | PVC Plastic | Not Rated | Gray | Anodized Aluminum | M12 | 1 | 0.875" | 1/2 | NPT | -40° to 175° | IP69 | UL Listed, C-UL Listed | 0000000 | 000000 |


Housing Thread | Mounting Thread | Environmental Rating | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Cable Industry Designation | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Size | Pitch, mm | Temperature Range, °F | M12 Connection | RJ45 Connection | Each | |
D-Code Female × RJ45 Female | |||||||||||||||
| 4 | Shielded | Category 5 | 100 Mbps | Silver | Plastic | M12 | 1 | 0.66" | M16 | 1.5 | -40° to 185° | IP65, IP67 | IP20 | 000000 | 000000 |


Housing Thread | Mounting Thread | Environmental Rating | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Cable Industry Designation | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Size | Pitch, mm | Temperature Range, °F | M12 Connection | RJ45 Connection | Each | |
D-Code Female × RJ45 Female | |||||||||||||||
| 4 | Shielded | Category 5 | 100 Mbps | Black | Plastic | M12 | 1 | 0.66" | M16 | 1.5 | -40° to 185° | IP65, IP67 | IP20 | 000000 | 000000 |
Food Industry Micro M12 Screw-Together Ethernet Connectors

FDA compliant to safely touch food and threaded for a tight hold, these connectors won’t vibrate loose as they send high-speed data to sensors and other automated devices in food, beverage, and pharmaceutical plants. They stand up to brief submersion as well as high-heat washdowns and harsh cleaners common to food lines, thanks to their IP ratings, TPE insulation, and stainless steel and polypropylene housing. Their insulation also means they’re flexible and won’t break down from abrasion or UV exposure. Overall, they’re more rugged than traditional RJ45 connectors.
To reduce the risk of signal loss between equipment, these connectors block signal interference from nearby devices. Poles and keyways on their face adhere to standard coding layouts, keeping you from mis-mating connections. D coded, these connectors are often used within Ethernet/IP, Profinet, and EtherCat systems. They can also power devices as they send data, so you don’t need a separate power cord. But, your device must be Power over Ethernet (PoE) compatible.
When choosing an Ethernet connector, make sure you match or exceed your network’s category industry designation. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
For technical drawings and 3-D models, click on a part number.
Housing Thread | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Number of Keyways | Voltage | Current, A | Wire Lead Gauge | Shielding | Transmission Speed, Mbps | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Specifications Met | Each | |
9.5 ft. Lg. Cable Leads | |||||||||||||
Wire Leads—External Thread | |||||||||||||
D-Code—Category 5E | |||||||||||||
| 4 | 2 | 60V DC | 4 | 22 | Shielded | 100 | M12 | 1 | -40° to 220° | IP65, IP68, IP69K | UL Listed, FDA Compliant 21 CFR 177.2600 | 0000000 | 000000 |
32.5 ft. Lg. Cable Leads | |||||||||||||
Wire Leads—External Thread | |||||||||||||
D-Code—Category 5E | |||||||||||||
| 4 | 2 | 60V DC | 4 | 22 | Shielded | 100 | M12 | 1 | -40° to 220° | IP65, IP68, IP69K | UL Listed, FDA Compliant 21 CFR 177.2600 | 0000000 | 000000 |
M8 Ethernet Connectors
The threaded end of these M8 connectors keeps contaminants out and withstands vibration better than RJ45 ends on traditional Ethernet cords. They are often used with sensors, switches, and I/O modules. To protect against signal interference, these connectors are shielded. Connectors are Power over Ethernet (POE) enabled to carry data and power within one connector.
To view wiring diagrams, select a part number and click Product Detail.
Snap-on wire connections pierce wire insulation, eliminating the need for wire stripping. They maintain a secure hold in high-vibration applications.
Connectors with a polyurethane cable bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil.
These connectors are IP rated when mated. IP65 rated connectors protect against dust and low-pressure jets of water. IP67 rated connectors keep out dust and water from temporary submersion.
For technical drawings and 3-D models, click on a part number.

Cable | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Number of Keyways | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | Wire Lead Gauge | OD | Lead Length, ft. | Outer Insulation Material | Shielding | Temperature Range, °F | Environmental Rating | Each | |
D-Coded—Category 5 | ||||||||||||||
| 4 | 3 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 3 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | 0000000 | 000000 |
| 4 | 3 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 6.5 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | 0000000 | 00000 |
| 4 | 3 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 16 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | 0000000 | 00000 |
| 4 | 3 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 32.5 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | 0000000 | 000000 |

| Number of Poles | Number of Keyways | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Shielding | Temperature Range, °F | Environmental Rating | Each | |
D-Coded—Category 5 | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.24"-0.26" | Shielded | -40° to 185° | IP65, IP67 | 0000000 | 000000 |

| Number of Poles | Number of Keyways | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Shielding | Temperature Range, °F | Environmental Rating | Each | |
D-Coded—Category 5 | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.24"-0.26" | Shielded | -40° to 185° | IP65, IP67 | 0000000 | 000000 |