For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
Flow Rate Flow Rate |
---|
|
Pump Type Pump Type |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Housing Material Housing Material |
---|
|
For Container Size For Container Size |
---|
|
Discharge Pipe Size Discharge Pipe Size |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Discharge Connection Type Discharge Connection Type |
---|
|
Maximum Self-Priming Height Maximum Self-Priming Height |
---|
|
Intake Connection Type Intake Connection Type |
---|
|
Concentration Ratio Concentration Ratio |
---|
|
Discharge Connection Style Discharge Connection Style |
---|
|
Flow Adjustment Mechanism Flow Adjustment Mechanism |
---|
|
Intake Connection Style Intake Connection Style |
---|
|
Runs Dry Runs Dry |
---|
|
More
More
More
More
Inject chemicals into your water supply without using electricity—these pumps install directly in your pipeline and activate when water flows into the pump head. They provide consistent metering regardless of pressure and flow changes and have an adjustment dial for altering dosing concentration. Pumps are often used with bleach, cleaning solutions, and water-treatment chemicals. All are self-priming and create suction to draw liquid upward. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Max. Pressure, psi | Max. Viscosity, cP | Concentration Ratio | Max. Temp., °F | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Dia. | Ht. | Includes | Each | |
0.05-14 | 85 | 200 | 1:500 to 1:50 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 19" | 6-ft. PVC Plastic Intake Tube | 0000000 | 0000000 |
0.05-14 | 85 | 200 | 1:3,000 to 1:333 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 21" | 6-ft. PVC Plastic Intake Tube | 0000000 | 00000000 |
0.05-14 | 85 | 1,700 | 1:100 to 1:10 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 19" | 6-ft. PVC Plastic Intake Tube | 0000000 | 00000000 |
0.05-14 | 85 | 1,700 | 1:200 to 1:20 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 19" | 6-ft. PVC Plastic Intake Tube | 0000000 | 00000000 |
With a nozzle and hose, these pumps allow you to dispense directly into your container. They move liquid by pressurizing the drum, so they have few moving parts prone to wear and tear. They are often used with fuel and lubricating oil. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. Pumps come set at 6 psi.
Temp. Range, °F | Air Connection | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | ID | Lg., ft. | Each | |
18 | 55 | 1,200 | Not Rated | 140° | 10-120 | 6 | 2 NPT | Air Hose Quick-Connect Coupling | 1/4 | Female | NPT | 1 1/4" | 21"-36" | 3/4" | 8 | 0000000 | 0000000 |
Replacement Hose with Nozzle | 000000 | Each | 0000000 |
Since these pumps move liquid by pressurizing your drum, they have few moving parts prone to wear and tear. They are often used with fuel and lubricating oil. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. Pumps come set at 6 psi.
Temp. Range, °F | Air Connection | Intake | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Spout Type | Each | |
18 | 55 | 1,200 | Not Rated | 125° | 10-120 | 6 | 2 NPT | Air Hose Quick-Connect Coupling | 1/4 | Female | NPT | 1 1/4" | 21"-36" | Removable | 0000000 | 0000000 |
Hose with Nozzle | 000000 | Each | 0000000 |
A nozzle and hose allow you to dispense directly into your container. The lever handle maximizes output with each stroke for low-effort dispensing. The handle delivers fluid on both the forward and backward strokes to quickly move drum contents. Lock the handle with a padlock (not included). Flow is reversible.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with metering nozzle record flow rate for batches and total volume. The batch meter is resettable and registers up to 99.9 gallons. The meter for total volume is nonresettable and registers up to 99,999.99 gallons.
Repair kits include components such as gaskets, valve assemblies, and piston rings.
Temp. Range, °F | Intake | Discharge | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Hose OD | Hose Lg., ft. | Max. Shackle Dia. | Each | |
Pumps with Metering Nozzle | |||||||||||||
26 | 15-55 | 319 | -15° | 150° | 2 NPT | Drum Connector | 1" | 20"-35" | 5/8" | 8 | 1/4" | 0000000 | 0000000 |
These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | For Discharge Tube ID | Spout Type | Each | |
Stainless Steel Intake Tube and Housing | ||||||||||||
6, 8, 10, 12 | 15-55 | 2,000 | Not Rated | 140° | 1 1/2 NPT, 2 NPT | Drum Connector | 1 1/8" | 18 1/2"-32 1/2" | 11/16" | Removable | 0000000 | 0000000 |
Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
Style C pumps have a steel enclosure that protects the motor from dusty, dirty, and damp environments.
Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation. Pedestal kit converts your pump from a drum mount to a pedestal mount.
Temp. Range, °F | Intake | Discharge | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max.Lift, ft. | For Drum Opening Size | Gender | Pipe Size | Thread Type | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Max. Shackle Dia. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
20 | 22 | 10 | -40° | 150 | 1/3 hp | 5.5 | 10 | 2 NPT | Female | 1 1/4 | NPT | 3/4" | 12 | 1 1/8" | Lockable, Manual Shut-Off, Metering | 3/8" | Hardwire | 0000000 | 0000000 |
Temp. Range, °F | Intake | Discharge | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max.Lift, ft. | For Drum Opening Size | Gender | Pipe Size | Thread Type | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Max. Shackle Dia. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
18 | 22 | 10 | -40° | 150 | 1/3 hp | 5.5 | 10 | 2 NPT | Female | 1 1/4 | NPT | 3/4" | 12 | 1 1/8" | Lockable, Manual Shut-Off, Metering | 3/8" | Hardwire | 0000000 | 000000000 |
Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with metering nozzle record total volume up to 99,999.9 gallons.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | ID | Lg., ft. | Nozzle Type | Each | |
For 12V DC Battery Voltage, Single Phase—With Thermal Overload Protection | ||||||||||||||||
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Metering, Manual Shut-Off | 0000000 | 0000000 |