McMaster-Carr logo
    Filter by
    Number of Displays
    Timer Resolution
    Maximum Number of Events
    Battery Size
    Mounting Location
    Enclosure Rating
    Industrial Info Compare
    Timing Adjustment Style
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Number of Circuits Controlled
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    92 Products

    Digital Timers

    Image of Product. Front orientation. Timers. Digital Timers, Style A.
    Image of Product. Front orientation. Timers. Digital Timers, Style B.
    Image of Product. Front orientation. Timers. Digital Timers, Style C.
    Image of Product. Front orientation. Timers. Digital Timers, Style D.

    Style A

    Style B

    Style C

    Style D

    Image of Product. Front orientation. Timers. Digital Timers, Style E.
    Image of Product. Front orientation. Timers. Digital Timers, Style F.
    Image of Product. Front orientation. Timers. Digital Timers, Style G.
    Image of Product. Front orientation. Timers. Digital Timers, Style H.

    Style E

    Style F

    Style G

    Style H

    Image of Product. Front orientation. Timers. Digital Timers, Style J.
    Image of Product. Front orientation. Timers. Digital Timers, Style K.
    Image of Product. Front orientation. Timers. Digital Timers, Style L.
    Image of Product. Front orientation. Timers. Digital Timers, Style M.

    Style J

    Style K

    Style L

    Style M

    Image of Product. Front orientation. Timers. Digital Timers, Style N.
    Image of Product. Front orientation. Timers. Digital Timers, Style P.
    Image of Product. Front orientation. Timers. Digital Timers, Style Q.
    Image of Product. Front orientation. Timers. Digital Timers, Style R.

    Style N

    Style P

    Style Q

    Style R

    Image of Product. Front orientation. Timers. Digital Timers, Style S.
    Image of Product. Front orientation. Timers. Digital Timers, Style T.
    Image of Product. Front orientation. Timers. Digital Timers, Style U.
    Image of Product. Front orientation. Timers. Digital Timers, Style V.

    Style S

    Style T

    Style U

    Style V

    Image of Product. Front orientation. Timers. Digital Timers, Style W.
    Image of Product. Front orientation. Timers. Digital Timers, Style X.
    Image of Product. Front orientation. Timers. Digital Timers, Style Y.

    Style W

    Style X

    Style Y

    Timers with Calibration Certificate Traceable to NIST Timers—Timers with a calibration certificate traceable to NIST have been tested to NIST standards to ensure accuracy.
    Style S—Style S timers have an extra-loud alarm that can be heard over background noise in a typical manufacturing environment.
    Memory Function—Timers with a memory function automatically return the display to the last programmed time. Good for timing repetitive intervals.
    IP65 Enclosure Rating—IP65-rated timers protect against dust and low-pressure washdowns. They also resist impacts up to 4 ft.
    Case
    Style
    Timing Functions
    Max. No.
    of Events
    Max. Timer
    Duration
    Max. Alarm
    Duration
    Timer
    Resolution
    Ht.
    Wd.
    Dia.
    Dp.
    Material
    Color
    Backing
    Type
    Batteries
    Included
    Features
    Enclosure
    Rating
    Each
    Timers
    ACount Up
    Count Down
    Pause
    1100 min.12 sec.1 sec.2 3/4"2 3/8"1/4"PlasticGrayMagneticYesAlarm12315T25000000
    BCount Up
    Count Down
    Pause
    1100 min.12 sec.1 sec.2 1/8"2 1/2"1"PlasticWhiteMagneticYesAlarm
    Built-In Stand
    Memory Function
    12475T370000
    CCount Up
    Count Down
    Pause
    Clock
    124 hr.Continuous1 sec.1 3/4"3 1/8"PlasticWhiteYesAlarm
    Memory Function
    12175T7500000
    DCount Up
    Count Down
    Pause
    124 hr.12 sec.1 sec.2 1/2"3 3/4"1"PlasticGrayMagneticYesAlarm
    Built-In Stand
    Memory Function
    12595T900000
    ECount Up
    Count Down
    Pause
    19,999 min.Continuous1 min.2"3"5/8"PlasticRedMagneticYesAlarm
    Built-In Stand
    Memory Function
    3879T4200000
    FCount Up
    Count Down
    Pause
    Clock
    124 hr.1 min.1/100 sec.3 3/4"3 3/4"3"PlasticGrayYesAlarm
    Built-In Stand
    Memory Function
    1223T800000
    GCount Up
    Count Down
    Pause
    Clock
    4100 hr.1 min.1 sec.2 1/2"2 3/4"1/2"PlasticWhiteYesAlarm
    Memory Function
    12525T200000
    HCount Up
    Count Down
    Pause
    Clock
    6100 hr.1 min.1 sec.2 3/8"2 3/4"1"PlasticGrayYesAlarm
    Memory Function
    9608T1100000
    JCount Up
    Count Down
    Clock
    23,000 day15 sec.1/100 sec.2 7/8"5"7/8"PlasticSilverYesBuilt-In Stand3879T11100000
    KCount Up
    Count Down
    224 hr.1 min.1 sec.3 3/4"5"1/2"PlasticWhiteYesAlarm
    Memory Function
    3879T11400000
    LCount Up
    Count Down
    4100 hr.1 min.1 sec.2 7/8"2 1/2"1/2"PlasticBlackMagneticYesAlarm
    Built-In Stand
    3879T11500000
    MCount Up
    Count Down
    124 hr.5 min.1 sec.5 1/4"7 3/4"1"PlasticBlackYesAlarm
    Built-In Stand
    Memory Function
    IP65
    12595T2300000
    NCount Up
    Count Down
    1100 min.1 min.1 sec.2 1/2"4"1"PlasticWhiteMagneticYesBuilt-In Stand
    Clip
    Vibrating Alarm
    12595T2200000
    PCount Up424 hr.Continuous1 min.5 1/2"8 7/8"1"PlasticWhiteMagneticYesAlarm
    Built-In Stand
    Clip
    Dry Eraseable
    12595T2100000
     
    Timers with Calibration Certificate Traceable to NIST Timers
    ECount Up
    Count Down
    Pause
    19,999 min.Continuous1 min.2"3"5/8"PlasticRedMagneticYesAlarm
    Built-In Stand
    Memory Function
    3879T4300000
    JCount Up
    Count Down
    Clock
    23,000 day15 sec.1/100 sec.2 7/8"5"7/8"PlasticSilverYesBuilt-In Stand3879T11600000
    QCount Up
    Count Down
    Pause
    1100 min.1 min.1 sec.2 1/4"2 1/2"1/2"PlasticBlueMagneticYesAlarm
    Built-In Stand
    8456T1200000
    RCount Up
    Count Down
    Pause
    Clock
    224 hr.1 min.1 sec.2 1/8"2 3/4"7/8"PlasticBlackMagneticYesAlarm
    Built-In Stand
    Memory Function
    6099T7700000
    SCount Up
    Count Down
    Pause
    2100 hr.1 min.1 sec.3"3 1/2"5/8"PlasticWhiteMagneticYesAlarm
    Built-In Stand
    Memory Function
    3516T4600000
    TCount Up
    Count Down
    Pause
    Clock
    320 hr.1 min.1 sec.3 7/8"2 5/8"1"PlasticBlackYesAlarm
    Memory Function
    1399T1500000
    UCount Up
    Count Down
    1100 hr.1 min.1 sec.2"1 1/2"3/4"PlasticWhiteMagneticYesAlarm
    Clip
    Keychain Ring
    6099T11200000
    VCount Up
    Count Down
    1100 min.1 min.1 sec.2 3/4"3"1"PlasticWhiteYesAlarm
    Built-In Stand
    6099T11300000
    WCount Up
    Count Down
    1100 min.1 min.1 sec.3 1/4"3"1/2"PlasticWhiteYesAlarm
    Built-In Stand
    Memory Function
    Suction Cups
    Waterproof
    6099T11400000
    XCount Down3100 hr.1 min.1 sec.3 1/4"2"1/2"PlasticWhiteMagneticYesAlarm
    Built-In Stand
    Memory Function
    6099T11600000
    YCount Up
    Count Down
    124 hr.1 min.1 sec.3 1/4"2 1/2"1/2"PlasticWhiteYesAlarm
    Built-In Stand
    Memory Function
    Repeat Function
    Voice Alerts
    6099T11700000
     

    Panel-Mount Set-to-the-Minute Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Panel-Mount Set-to-the-Minute Time and Day Activated Switches, 7-Day Timing Cycle, 1 Circuit Controlled.
    Image of Product. Front orientation. Timer Switches. Panel-Mount Set-to-the-Minute Time and Day Activated Switches, 7-Day Timing Cycle, 2 Circuits Controlled.

    7-Day Timing Cycle

    1 Circuit Controlled

    7-Day Timing

    Cycle, 2 Circuits

    Controlled

    Install these switches in a panel cutout. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. The seven-day timing cycle can perform a different program each day of the week. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
    2 Circuits Controlled—Two-circuit switches can apply a different program to each circuit.
    For Panel
    Cutout
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    With
    Override
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Wire
    Connection
    Certification
    Each
    7-Day Timing Cycle—With Battery Backup
    115 amp @ 277V AC12V AC/24V AC/24V DC201Push ButtonYesSPDT
    2.8"2.8"1.5"2.63"2.63"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K910000000
    115 amp @ 277V AC120V AC/277V AC201Push ButtonYesSPDT
    2.8"2.8"1.5"2.63"2.63"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K111000000
    215 amp @ 250V AC120V AC/240V AC201Push ButtonYesSPST-NO
    2.8"2.8"2.2"2.68"2.68"Screw TerminalUL Recognized Component, CSA Certified
    70395K81000000
     

    Large-Display Digital Timers

    Image of System. Front orientation. Contains Annotated. Timers. Large-Display Digital Timers.
    Read elapsed or remaining time from up to 150 ft. away—roughly half the length of a football field. These timers count up and down from zero. When counting down past zero, they flash and display a negative symbol before the time. To start, pause, and reset these timers, they require a controller (sold separately).
    Controllers—The controller comes with a 20 ft. RJ45 cable to connect it to the timer.
    Splitters—Add a splitter to connect two timers to the same controller.
    Timers
    Controllers
    Splitters
    Case
    Timing Functions
    Max. No.
    of Events
    Max. Timer
    Duration, hr.
    Max. Alarm
    Duration
    Timer Resolution,
    sec.
    Ht.
    Wd.
    Dp.
    Material
    Color
    Electrical
    Connection Type
    Includes
    Features
    Each
    Each
    Each
    Count Up
    Count Down
    Pause
    1100Continuous16 1/4"15 1/2"1 1/2"PlasticBlackHardwireMounting BracketAlarm7384N1200000007384N1100000007384N13000000
     

    Smart DIN-Rail Mount Multifunction Timer Relays

    Image of ProductInUse. Front orientation. Timer Relays. Smart DIN-Rail Mount Multifunction Timer Relays, 1 Circuit Controlled.
    Image of ProductInUse. Front orientation. Timer Relays. Smart DIN-Rail Mount Multifunction Timer Relays, 2 Circuits Controlled.

    1 Circuit Controlled

    2 Circuits Controlled

    Whether installed in an electrical cabinet or hard-to-reach area, these timer relays are controlled remotely from your smartphone. They connect to your phone via a free downloadable app with NFC (Near Field Communication), so you can set time delay ranges, adjust settings, and save programs. An LED indicator on the relay shows that your switch is on and whether it’s actuated. Mount them directly to 35 mm DIN rail (also known as DIN 3 rail).
    Although these relays have 30 different functions, they all fall into 11 categories. Within these categories, you can select different functions to allow you to add a switch, program a delay, or change how the relay responds to a trigger (turning on or off, pausing, or resetting).
    Delayed Start (Delay on Make) Timer—These functions allow you to set how long it takes for the relay to turn on after input voltage is applied. For example, a drill starts pumping lubricant immediately, but it does not start rotating until the set time has elapsed.
    Delayed Switch Off (Delay on Break) Timer—These functions use a switch instead of input voltage. When the switch is turned off, the relay remains on for a programmed amount of time before turning off. For example, a projector’s light is turned off with a switch, but its cooling fan continues to run for a set time.
    Delayed Switch-On with Delayed Switch-Off Timer—This function uses a switch instead of an input voltage. It allows you to set how long it takes the relay to turn on after a switch is turned on, and how long it will stay on after the switch is turned off. For example, a furnace turns on, but the fan doesn’t start pushing air through the vents until it has been heated. When the furnace turns off, the fan keeps blowing to circulate all the hot air.
    Interval Timer—These functions use input voltage to turn on the relay for a programmed amount of time. For example, when a part moving down a conveyor reaches a certain location, a cleaning spray comes on for a set amount of time.
    Switch on (Single Shot) Timer—These functions require a switch to activate the relay, which stays on for the programmed amount of time. For example, lights in a storage room are turned on with a switch and stay on for a set time before turning off.
    Repeat-Cycle Timer—These functions start with an on cycle and then alternate between an on cycle and off cycle of equal durations until input voltage is removed, such as with a flashing light.
    Asymmetrical-Repeat-Cycle Timer—These functions start with an on-cycle and then have an off-cycle, but these cycles have different durations. The cycles repeat until input voltage is removed. For example, a sprinkler system sprays in short bursts followed by longer rest periods, on and off until input voltage is removed.
    Manual-Switch-Control Timer—Use these functions to turn the relay on and off with a switch.
    Fixed On/Off Timer—The on function keeps the relay on whenever input voltage is applied; it will only turn off if the voltage is removed. The off function keeps the relay in an off state, even if input voltage is applied.
    Star-to-Delta Timer—These functions allow you to set the time delay within the relay's range to switch contacts on a three-phase motor from star to delta configuration. Since star configuration takes less voltage to start than delta, these functions prevent voltage dips that often happen when a motor starts and are gentler on mechanical parts.
    Switch-On Asymmetrical Repeat Cycle Timer—These functions require a switch to activate the timing function. The input voltage is applied the whole time, and when you turn the switch on, the relay begins with an on-cycle followed by an off-cycle. These cycles have different durations, and they repeat until you turn the switch off. They could be used to turn on a motor or other system for a short period and then turn it off for a longer rest period, repeating that pattern until the switch is turned off.
    No. of
    Terminals
    Input Voltage
    Control
    Power, W
    Timer Relay Function
    Overall Timing
    Range
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Operating System Compatibility
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    812V AC, 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC0.15Manual Switch Control
    Fixed On/Off
    Switch on (Single Shot)
    Delayed Start (Delay on Make)
    Delayed Switch Off (Delay on Break)
    Delayed Switch-On with Delayed Switch-Off
    Interval
    Repeat Cycle
    Asymmetrical Repeat Cycle
    Switch-On Asymmetrical Repeat Cycle
    0.1 sec. to 999 day8 amp @ 240V AC2504.1"0.7"2.5"Android 5.0 or Later, iOS 14.4 or LaterLED Indicator8491N12000000
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    924V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC0.6Manual Switch Control
    Fixed On/Off
    Switch on (Single Shot)
    Delayed Start (Delay on Make)
    Delayed Switch Off (Delay on Break)
    Delayed Switch-On with Delayed Switch-Off
    Interval
    Repeat Cycle
    Asymmetrical Repeat Cycle
    Switch-On Asymmetrical Repeat Cycle
    Star-to-Delta
    0.1 sec. to 999 hr.8 amp @ 240V AC2503.5"0.9"2.9"Android 4.4 or Later, iOS 14.5 or LaterLED Indicator8491N11000000
     

    Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    365-Day Timing Cycle—Seven-day/365-day switches can perform a different program each day of the week or year, and compensate for leap year and daylight savings time. Override regular programming for up to 99 holidays for any length of time. They can also be used to activate equipment such as bells and signals for just a few seconds.
    Astronomical Timing—Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Mounting
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Hole
    Dia.
    Knockout
    Trade Size
    Wire
    Connection
    Environment
    Certification
    Each
    24-Hr. Timing Cycle—With Battery Backup, Lockout
    130 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    SPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K650000000
    230 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K67000000
     
    7 day—With Battery Backup, Lockout, Day Skipper
    230 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K86000000
     
    7 day—With Battery Backup, Lockout, Day Skipper, Astronomical Timing
    130 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    SPDT
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K91000000
     
    7 day/365 day—With Battery Backup, Lockout, Astronomical Timing
    130 amp @ 240V AC120/208/240/2774,000 per yr.1Push ButtonSteelSPDT
    8 5/8"5 3/4"3 5/8"No0.19"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed, CSA Certified
    70915K77000000
    230 amp @ 240V AC120/208/240/2774,000 per yr.1Push ButtonSteelSPDT
    8 5/8"5 3/4"3 5/8"No0.19"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed, CSA Certified
    70915K81000000
     

    Set-to-the-Minute High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Set-to-the-Minute High-Current Time and Day Activated Switches.
    For precise control of high-current equipment such as landscape lighting, pumps, and heaters, these switches schedule on/off times to the exact minute. A backup battery or capacitor maintains the program during a power outage.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week. They have a day skipper that can suspend operation for one to six days.
    2 Circuits Controlled—Two-circuit switches can apply a different program to each circuit.
    Mounting
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Hole
    Dia.
    Knockout
    Trade Size
    Wire
    Connection
    Environment
    Certification
    Each
    7 day—With Battery Backup, Lockout, Day Skipper
    230 amp @ 240V AC120/208/240/277281Push ButtonSteelSPST, DPST
    7 3/4"5"3"No0.16"1/2, 3/4
    Screw TerminalIndoor OnlyUL Listed, CSA Certified
    7459K890000000
     
    24-Hr. Timing Cycle—With Capacitor Backup, Lockout
    130 amp @ 240V AC120/208/240/277481Push ButtonSteelSPST
    7 7/8"5 1/8"3 7/16"No3/16"1/2, 3/4
    Screw TerminalIndoor OnlyUL Listed, CSA Certified
    7459K81000000
    230 amp @ 240V AC120/208/240/277481Push ButtonSteelSPST, DPST
    7 7/8"5 1/8"3 7/16"No3/16"1/2, 3/4
    Screw TerminalIndoor OnlyUL Listed, CSA Certified
    7459K82000000
     
    7-Day Timing Cycle—With Capacitor Backup, Day Skipper, Lockout
    130 amp @ 240V AC120/208/240/277481Push ButtonSteelSPST
    7 7/8"5 1/8"3 7/16"No3/16"1/2, 3/4
    Screw TerminalIndoor OnlyUL Listed, CSA Certified
    7459K83000000
     

    Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Time and Day Activated Switches, 7-Day Timing Cycle.

    7-Day Timing Cycle

    Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Astronomical Timing—Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
    Electrical
    Switching Current
    @ Voltage
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    With
    Override
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Connection
    No. of
    Blades
    Certification
    Each
    7-Day Timing Cycle—With Astronomical Timing, Random On/Off Option
    15 amp @ 120V AC141Push ButtonYes23"3 1/2"3 1/2"Straight Blade3UL Listed, C-UL Listed
    7001K58000000
     

    Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches, 24-Hr. Timing Cycle.
    Image of Product. Front orientation. Timer Switches. Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches, 7-Day Timing Cycle.

    24-Hr. Timing Cycle

    7-Day Timing Cycle

    Mount these switches to a flat surface or attach to DIN rail. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
    24-Hr. Timing Cycle—24-hour switches repeat the same program daily. They control two circuits and can apply a different program to each circuit.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Mounting
    For Panel
    Cutout
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    With
    Override
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    No. of
    Holes
    For DIN
    Rail Ht., mm
    Ht.
    Wd.
    Wire
    Connection
    Certification
    Each
    24-Hr. Timing Cycle—With Battery Backup
    215 amp @ 250V AC120V AC/240V AC121Push ButtonYesSPST-NO
    3.8"3.8"2.2"No2353.62"3.62"Screw TerminalUL Recognized Component, CSA Certified
    70395K710000000
     
    7-Day Timing Cycle—With Battery Backup
    115 amp @ 277V AC12V AC/24V AC/24V DC201Push ButtonYesSPDT
    4.1"2.9"2.2"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K161000000
    115 amp @ 277V AC120V AC/277V AC201Push ButtonYesSPDT
    4.1"2.9"2.2"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K171000000
    115 amp @ 277V AC120V AC/277V AC501Push ButtonYesSPDT
    4.1"2.9"2.2"Screw TerminalUL Recognized Component, C-UL Recognized Component
    71075K211000000
     

    Smart Time and Day Activated Switches

    Image of ProductInUse. Front orientation. Contains MultipleImages. Timer Switches. Smart Time and Day Activated Switches.
    Use your smart phone to turn equipment on and off at a set time and day. These switches connect to your phone via NFC (near field communication) and work with a free app to set schedules, adjust settings, and save programs. They can perform a different program each day of the week, and they compensate for leap year and daylight savings time. You can remotely apply programs across compatible switches, so it’s easy to reprogram lighting or equipment in large facilities. These switches mount to a flat surface or attach to DIN rail.
    Astronomical Timing—Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage
    Max. On/Off
    Cycles, per wk.
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Electrical
    Connection
    Operating System Compatibility
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Certification
    Each
    7-Day Timing Cycle
    116 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickSPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    7818N1010000000
    216 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickDPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    7818N102000000
     
    7-Day Timing Cycle—With Astronomical Timing
    116 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickSPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    7818N103000000
    216 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickDPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    7818N104000000
     

    Stopwatches

    Image of Product. Front orientation. Stopwatches. Stopwatches, Style A.
    Image of Product. Front orientation. Stopwatches. Stopwatches, Style B.
    Image of Product. Front orientation. Stopwatches. Stopwatches, Style D.
    Image of Product. Front orientation. Stopwatches. Stopwatches, Style E.

    Style A

    Style B

    Style D

    Style E

    Image of Product. Front orientation. Stopwatches. Stopwatches, Style F.
    Image of Product. Front orientation. Stopwatches. Stopwatches, Style G.
    Image of Product. Front orientation. Stopwatches. Stopwatches, Style H.

    Style F

    Style G

    Style H

    Quickly view starts and finishes on a digital screen.
    Stopwatches with Calibration Certificate Traceable to NIST—Stopwatches with a calibration certificate traceable to NIST have been tested to NIST standards to ensure accuracy.
    Case
    Style
    Timing Functions
    Max. Timer
    Duration
    Accuracy
    Max. No. of
    Laps Stored
    Material
    Color
    Lens
    Material
    Water
    Resistance
    Backing
    Type
    Batteries
    Included
    Features
    Includes
    Each
    Stopwatches
    ACount Up, Split, Lap10 hr.±0.04 sec./1 hr.PlasticBlackPlasticWater ResistantYesLanyard1314T15000000
    BCount Up, Split, Lap, Pause, Count Down10 hr.±0.04 sec./1 hr.PlasticBlackPlasticWater ResistantYesAlarmLanyard8434T1300000
    DCount Up, Count Down100 min.±0.08 sec./1 hr.PlasticWhiteGlassNoneMagneticYesAlarmLanyard2504T1500000
    ECount Up, Split, Lap, Count Down, Clock10 hr.±0.2 sec./1 hr.30PlasticGreenPlasticNoneYesAlarm, Thermometer, Humidity IndicatorLanyard2504T1600000
     
    Stopwatches with Calibration Certificate Traceable to NIST
    ACount Up, Split, Lap10 hr.±0.0216PlasticBlackPlasticWater ResistantYesLanyard1314T1900000
    FCount Up, Split, Lap, Pause, Clock24 hr.±0.04 sec./1 hr.PlasticBlackPlasticWater ResistantYesAlarmLanyard6327T7700000
    GCount Up, Split, Pause, Clock24 hr.±0.4 sec./1 hr.PlasticYellowPlasticWater ResistantYesAlarmLanyard6327T4400000
    HCount Up, Split, Lap, Pause, Count Down10 hr.±0.04 sec./1 hr.300PlasticGrayGlassWater ResistantYesAlarmLanyard2504T1700000
     
    Clipboards

    Wall-Mount Timer Switches

    Use these switches in place of standard wall switches to automatically turn electrical equipment on or off after a set interval of time. They’re often used with lights.
    Push Button with Countdown LCD, Set Time Recall and Beep and Light Alerts
    Image of Product. Front orientation. Timer Switches. Wall-Mount Timer Switches, Countdown LCD, Timing-Adjustment Push Button.
    Switches with set time recall retain the last setting; hold the button down to restart the timer with that setting.
    Set switches with beep and light signals to alert when the timer is almost done; the signals can also be turned off.
    With Override—Switches with override can bypass the automatic shut-off.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current @ Voltage
    hp @ Switching
    Voltage
    Set Time
    For Outlet Box
    Designation
    Wire
    Connection
    Choose a Color
    Each
    With Override
    11 Off
    41 mA @ 24V AC, 12 mA @ 24V DC5 min. to 12 hr.1 Gang
    Screw Terminal
    Almond
    ,
    Black
    ,
    Gray
    ,
    Ivory
    ,
    White
    6550T20000000
    11 Off
    6.6 amp @ 120V AC, 4.3 amp @ 277V AC1/6 hp @ 125V AC5 min. to 12 hr.1 Gang
    Screw Terminal
    Almond
    ,
    Black
    ,
    Gray
    ,
    Ivory
    ,
    White
    6550T100000
     

    Faucet Timers for Handwashing

    Image of ProductInUse. Front orientation. Faucet Timers. Faucet Timers for Handwashing.
    Image of Product. Front orientation. Faucet Timers. Faucet Timers for Handwashing.
    Attach these timers to faucets to make sure you’re following handwashing protocols that help prevent the spread of illness. Most health organizations recommend washing your hands for at least 20 seconds to eliminate germs. These timers have a 30-second countdown, which is enough time to pump soap, wash for 20 seconds, and rinse your hands. An easy-to-read LCD display shows you the amount of time you have left. They also beep to alert you when the countdown is done, so you don’t have to watch the timer.
    These timers are touch-free—a sensor triggers the countdown as soon as water starts flowing, and they automatically reset after 30 seconds. The countdown continues even if the flow of water stops, so you can install them on both manual and touch-free sinks. Connect timers directly to a male-threaded faucet, or use the male adapter to connect to a female-threaded faucet. They include a wrench, so you don’t need tools on hand to install them.
    Made from impact-resistant ABS, these timers hold up to bumps and scrapes from regular use. The chrome finish blends in with silver faucets. An aerator at the base of the timer prevents splashes and helps create a smooth flow of water. They also have a rubber gasket to keep water from leaking through the faucet connection.
    Thread
    Size
    Gender
    Timer Duration,
    sec.
    Dia.
    Ht.
    Flow Rate,
    gpm
    Batteries
    Included
    Features
    Includes
    Each
    55/64"-27
    Female302 7/8"5 1/4"2YesAuto Reset, LCD Display15/16"-27 Male Adapter, Wrench4282N110000000

    Outdoor Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor Time and Day Activated Switches, 24-Hr. Timing Cycle.
    Image of Product. Front orientation. Timer Switches. Outdoor Time and Day Activated Switches, 7-Day Timing Cycle.

    24-Hr. Timing Cycle

    7-Day Timing Cycle

    Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week. They have astronomical timing that can be set to turn lights on and off based on sunrise and sunset.
    NEMA 3R Enclosure Rating—NEMA 3R rated switches are protected against falling liquids and light splashing.
    Light Sensor Control—Switches with light sensor control allow one device to be controlled by the presence or absence of light.
    Electrical
    Mounting
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Tripper
    Type
    No. of
    Trippers
    Switching Current
    @ Voltage
    No. of
    Outlets
    Features
    Ht.
    Wd.
    Dp.
    Connection
    No. of
    Blades
    Cord Lg.,
    ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Min. Ht.,
    ft.
    Each
    24-Hr. Timing Cycle—NEMA 3R
    1230TripperRemovable415 amp @ 120V AC2Light Sensor Control9 3/8"5 1/2"3 3/8"Straight Blade32No41/4"7185K260000000
     
    7-Day Timing Cycle
    71Push Button15 amp @ 120V AC2Astronomical Timing, Random On/Off Option5 1/8"5 1/4"1 7/8"Straight Blade32No20.31"4.57001K5600000
     
    Trippers

    Scheduling Timers

    Image of Product. Front orientation. Scheduling Timers.
    Image of Product. Front orientation. ZoomedIn view. Contains Border. Scheduling Timers.
    Program this timer to trigger an audible signal for events throughout the week such as lunch and break times. It has a keypad for scheduling events and adjusting the signal duration. Keypad has a user-defined security code to restrict access. The backup battery saves programmed data and lasts for 10 years. It does not power the timers.
    Timers
    Replacement
    Backup Batteries
    Max. No. of
    Events per wk.
    For Max. No.
    of Alarms
    Alarm Duration, sec.
    Ht.
    Wd.
    Dp.
    Material
    Color
    Time Convention,
    hr.
    Electrical
    Connection Type
    Current,
    amp
    Voltage,
    V AC
    Backup Battery
    Life, yr.
    Each
    Pkg.
    Qty.
    Pkg.
    9,9999,9991 to 9, Continuous8 1/2"11"6 1/2"Polycarbonate
    Gray12, 24Hardwire2.5120109579T4200000000017701K3400000
    Audible Alarms

    Metal- and X-Ray-Detectable Stopwatches

    Image of Product. Front orientation. Stopwatches. Metal- and X-Ray-Detectable Stopwatches.
    Image of Product. Breakaway Clasp. Front orientation. Contains Border. Stopwatches. Metal- and X-Ray-Detectable Stopwatches.

    Breakaway Clasp

    Track time on food processing lines while reducing the risk of contaminating the food. To help you comply with Hazard Analysis and Critical Control Point (HACCP) programs, these plastic stopwatches contain metal and chemical additives that will set off metal detectors and show up on X-ray machines. They’re also bright blue, so it’s easy to spot any broken pieces that may fall into your line. They are FDA compliant for direct contact with food.
    These stopwatches have a lanyard with a breakaway clasp, which keeps you safe while working near your line—the clasp will break if the lanyard gets caught.
    Case
    Timing Functions
    Max. Timer
    Duration, hr.
    Accuracy
    Timer Resolution,
    sec.
    Ht.
    Wd.
    Dp.
    Material
    Color
    Lens
    Material
    Batteries
    Included
    Features
    Includes
    Food Industry Std.
    Each
    Count Up, Pause, Clock8Not Rated1/1003"2"7/8"PlasticBluePlasticYesAlarm, Memory FunctionLanyardFDA Compliant 21 CFR 177.1520
    6934N11000000
     

    Outlet-Box-Mount Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outlet-Box-Mount Time and Day Activated Switches, 7-Day Timing Cycle.

    7-Day Timing

    Cycle

    Switches fit 1 gang outlet boxes. Program them to turn a device on and off at a set time and day. They’re often used with lamps and other small electrical loads.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Astronomical Timing—Use the astronomical timing to turn lights on and off based on sunrise and sunset; this option can be used independently or in combination with timed programming.
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Max. On/Off
    Cycles, per wk.
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    For Outlet Box
    Designation
    Wire
    Connection
    Wire Lead
    Lg.
    Certification
    Each
    7-Day Timing Cycle—With Astronomical Timing, Battery Backup, LCD Display
    115 amp @ 120V AC401Push Button1 Gang
    Wire Leads6"CSA-US Certified, CSA Certified
    7367K61000000
     

    Multifunction Smartwatches

    Image of ProductInUse. Front orientation. ZoomedIn view. Contains Border. Wristwatches. Multifunction Smartwatches, Compass.
    Image of ProductInUse. GPS Navigation. Front orientation. ZoomedIn view. Contains Border. GPS Navigation. Multifunction Smartwatches.
    Image of ProductInUse. Health and Fitness Tracking. Front orientation. ZoomedIn view. Contains Border. Health and Fitness Tracking. Multifunction Smartwatches.

    Compass

    GPS Navigation

    Health and Fitness

    Tracking

    Image of ProductInUse. Night Vision Mode. Front orientation. ZoomedIn view. Contains Border. Night Vision Mode. Multifunction Smartwatches.
    Image of ProductInUse. Weather and Elevation Monitoring. Front orientation. ZoomedIn view. Contains Border. Weather and Elevation Monitoring. Multifunction Smartwatches.
    Image of Product. Front orientation. Wristwatches. Multifunction Smartwatches.

    Night Vision Mode

    Weather and

    Elevation Monitoring

    Keep your phone in your pocket and your hands free—these smartwatches perform a variety of functions on your wrist. They connect to Apple and Android phones via Bluetooth, informing you when calls, texts, and other notifications arrive. Designed for harsh environments and rugged use, they meet military standards for resistance to hot and cold temperatures, shock, splashes, and submersion in up to 100 meters of water. These watches have a compass and GPS for tasks such as navigation, tracking and saving location coordinates, and calculating the area of a location by walking the perimeter. With weather and elevation monitoring, you can set the rate of barometric pressure change that will trigger a storm alert. These watches track health and fitness metrics over time, including heart rate, blood oxygen levels, and exercise. They have a solar battery in addition to a rechargeable lithium-ion one to extend the time between plug-in charging.
    Display
    Housing
    Band
    Lg.
    Wd.
    Display Time,
    hr.
    Temp. Range,
    ° F
    Material
    Color
    Material
    Color
    Closure
    Method
    Power Source
    Battery
    Life, day
    Features
    Mil. Spec.
    Each
    7/8"7/8"12, 240 to 140Fiber-Reinforced PlasticBlackSilicone Rubber
    BlackBuckleBattery, Solar28Compass
    GPS Navigation
    Health and Fitness Tracking
    Night Vision Mode
    Weather and Elevation Monitoring
    MIL-STD-8105262N110000000

    Combination Wristwatch/Weather Monitors

    Image of Product. Front orientation. Wristwatches. Combination Wristwatch/Weather Monitors.
    Monitor your environment when working outdoors. These wristwatches display time, date, temperature, barometric pressure, and altitude. They also have a stopwatch and digital compass.
    Stopwatch
    Housing
    Band
    Face
    Dia.
    Display Time,
    hr.
    Timing Function
    Max. Time,
    hr.
    Temp. Range,
    ° F
    Material
    Color
    Material
    Color
    Closure
    Method
    Power
    Source
    Each
    2 1/8"12, 24Count Down, Split1,00014 to 140PlasticBlackPlasticBlackBuckleSolar8431T620000000

    Time and Date Stamps

    Image of Product. Front orientation. Stamps. Desktop Mount, Time, Date.
    Record the time and date on invoices, freight bills, legal papers, and other time-sensitive documents. Stamp automatically prints when forms are inserted. Precision can be adjusted to penetrate multiple copies.
    Stamps
    Replacement
    Ink Ribbon
    Ht.
    Wd.
    Dp.
    Features
    Ink
    Color
    Electrical
    Connection Type
    Cord Lg.,
    ft.
    Each
    Each
    5 5/8"6 1/2"6 3/4"Digital DisplayBlackPlug In58389T2600000008389T27000000

    Total-the-Hours Time Clocks

    Image of Product. Front orientation. Time Clocks. Total-the-Hours Time Clocks.
    These clocks save you time at the end of a pay period by automatically totaling each employee’s hours on their time cards. They print automatically when a card is inserted. The display shows the date, day of the week, and time (an internal calendar auto-adjusts for daylight saving time). Time cards are sold separately.
    Time Clocks
    Replacement Keys
    For Max. No.
    of Employees
    Printing
    Method
    Ht.
    Wd.
    Dp.
    Material
    Color
    Ink
    Color
    Pay Period
    Records
    Date
    Recorded
    Electrical
    Connection Type
    Cord Lg.,
    ft.
    Mounting Hardware
    Included
    Includes
    Each
    Pkg.
    Qty.
    Pkg.
    Desktop and Wall Mount
    100Automatic7 1/4"7"6 1/2"PlasticBlackBlackWeekly, Biweekly, Semi-Monthly, MonthlyTimeDay, MonthPlug In5NoTwo Keys6838T21000000026838T24000000
     
    Accessories and Replacements for Time Clocks

    Proximity-Touch Time Clocks

    Image of ProductInUse. Front orientation. Time Clocks. Proximity-Touch Time Clocks.
    Record attendance with the touch of a badge or key fob. The included software lets you generate and edit reports. Upload data to your PC using a CAT5 ethernet cable. This clock is compatible with common payroll software such as QuickBooks and ADP. The display shows the time, date, and day of the week.
    Time Clocks
    Time Clock Badges
    Key Fobs
    For Max. No.
    of Employees
    Ht.
    Wd.
    Dp.
    Material
    Color
    Pay Period
    Records
    Date
    Recorded
    Tracks
    Overtime
    Mounting Hardware
    Included
    Includes
    Each
    Pkg.
    Qty.
    Pkg.
    Pkg.
    Qty.
    Pkg.
    Wall Mount
    505 3/4"5"2"PlasticBlackWeekly, Biweekly, Semi-Monthly, MonthlyTimeDay, MonthYesYes15 Time Badges, Software1116N110000000151116N1200000051116N13000000
     

    Time Clocks with Message Stamp

    Image of Product. Desktop. Front orientation. Time Clocks. Time Clocks with Message Stamp, 6" High.
    Image of Product. Desktop and Wall Mount. Front orientation. Time Clocks. Time Clocks with Message Stamp, 6 7/8" High.

    Desktop

    Desktop and Wall Mount

    Stamp your time cards with messages such as PAID and VOID as well as time information. Clocks print automatically when a card is inserted. The display shows the date and time (an internal calendar auto-adjusts for daylight saving time). The housing locks to prevent tampering. Time cards are sold separately.
    Create-Your-Own—Create-your-own-message clock lets you enter your own message up to 20 characters. Display includes day of the week.
    Time Clocks
    Replacement Keys
    Message
    Printing
    Method
    Ht.
    Wd.
    Dp.
    Material
    Color
    Ink
    Color
    Records
    Date Recorded
    Electrical
    Connection Type
    Cord Lg.,
    ft.
    Includes
    Each
    Pkg.
    Qty.
    Pkg.
    Desktop Mount
    Apr'd, Cfm'd, Cmpl'd, Fax'd, File, Orign, Paid, Rcv'd, Sent, VoidAutomatic6"5 1/2"6 1/2"PlasticBlackBlackMessage, TimeDay, Month, YearPlug In5One Key, One Lithium Backup Battery12735T320000000212735T7000000
     
    Desktop and Wall Mount
    Create-Your-OwnAutomatic6 7/8"5 7/8"6"PlasticBlackBlackMessage, TimeDay, Month, YearPlug In6One Key12735T34000000212465T900000
     
    Accessories and Replacements for Time Clocks
    back to top