McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    91 Products

    DIN-Rail Mount Fuse Blocks for UL Class CC Midget Fuses

    Image of Product. For 1 Fuse. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class CC Midget Fuses, For 1 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class CC Midget Fuses, For 2 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class CC Midget Fuses, For 3 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class CC Midget Fuses, For 4 Fuses.

    For 1 Fuse

    For 2 Fuses

    For 3 Fuses

    For 4 Fuses

    Covered terminals prevent contact with live electrical circuits.
    For Fuse
    For No.
    of Fuses
    UL
    Class
    Current,
    amp
    Type
    Voltage
    Wire
    Connection
    For DIN
    Rail Size, mm
    Features
    Wd.
    Ht.
    Dp.
    Certification
    Each
    For Fuse Manufacturer Equivalent: ATQ-R, ATM-R, ATD-R, CCMR, FNQ-R, KLD-R, KLK-R, KTK-R, LP-CC
    1CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals0.7"3.1"2.3"UL Listed, CSA Certified
    6113T11000000
    1CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals, Blown-Fuse Indicator0.7"3.1"2.3"UL Listed, CSA Certified
    6113T1400000
    2CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals1.4"3.1"2.3"UL Listed, CSA Certified
    6113T1200000
    2CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals, Blown-Fuse Indicator1.4"3.1"2.3"UL Listed, CSA Certified
    6113T1500000
    3CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals2.1"3.1"2.3"UL Listed, CSA Certified
    6113T1300000
    3CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals, Blown-Fuse Indicator2.1"3.1"2.3"UL Listed, CSA Certified
    6113T16000000
    4CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals2.8"3.1"2.3"UL Listed, CSA Certified
    6113T21000000
    4CC1/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals, Blown Fuse Indicator2.8"3.1"2.3"UL Listed, CSA Certified
    6113T22000000
     

    Modular DIN-Rail Mount Terminal Blocks

    Image of System. Front orientation. Contains Annotated. Terminal Blocks. Modular DIN-Rail Mount Terminal Blocks.
    Mix and match these terminal blocks to get the exact number of circuits you need in a single setup. Add blocks for thermocouples, fuses, and grounding wire as needed. The blocks clip side by side onto DIN rail in control panels, creating tidy rows of circuits that you can identify and access on the spot.
    The screw-clamp terminals flatten your wire so it stays put when vibrated or pulled. If you need to change wiring frequently without adjusting a screw, consider a quick-connect terminal block with spring-clamp or lever-clamp terminals.
    Fuse Terminal Blocks with Screw-Clamp Terminals
    Image of Product. Front orientation. Terminal Blocks. Modular DIN-Rail Mount Terminal Blocks, Fuse Terminal Blocks with Screw-Clamp Terminals.
    Install a fuse in the built-in fuse holder so excess current doesn't damage your equipment. If the current exceeds the limit, the fuse will blow and cut power to connected components.
    Blown Fuse Indicator—A light goes on when the fuse blows, so you can spot an overloaded circuit without cutting power or touching equipment.
    Covers—Snap onto the exposed side of a terminal block to prevent accidental contact with a live wire.
    End Stops—Mount at the end of a group of terminal blocks so they don't slide when vibrated or bumped.
    Bar Jumpers—Metal poles create an electrical connection between blocks, so you can connect multiple components with a single wire. Blocks must be the same width for the jumpers to fit. Cut jumpers to size with a hacksaw or high-force wire cutter. Add covers so jumpers don't touch the screws on the outermost blocks.
    Insulation—Terminal blocks with insulated jumpers maintain their IP20 rating to prevent shocks and short circuits. Blocks with noninsulated jumpers lose their IP20 rating for touch protection because the jumpers introduce exposed metal to the circuit.
    Terminal Blocks
    Covers
    End Stops
    Bar Jumpers
    For Fuse
    Each
    No. of
    Circuits
    No. of Terminals
    per Circuit
    For Wire
    Ga.
    Wd.,
    mm
    Ht.,
    mm
    Trade
    Size
    Overall
    Dia.
    Overall
    Lg.
    Type
    Circuit Status
    Indicator Type
    Blown Fuse Indicator
    Voltage
    For DIN Rail
    Trade Size
    Enclosure
    Rating
    Choose a
    Color
    1-24
    25-Up
    Each
    Each
    Insulation
    Each
     
    300V AC/300V DC—6.3 amp per Circuit
    2
    1 (Ground)
    2
    1 (Ground)
    20 to 128995 mm20 mmCeramic, Glass3IP20
    Gray7641K8610000000000007641K765000007641K75700000Noninsulated7641K16000000
    2
    1 (Ground)
    2
    1 (Ground)
    20 to 128995 mm20 mmCeramic, GlassBlown Fuse24V DC
    60V DC
    110V AC
    3IP20
    Gray7641K86400000000007641K76500007641K7570000Noninsulated7641K1600000
    2
    1 (Ground)
    2
    1 (Ground)
    20 to 128995 mm20 mmCeramic, GlassBlown Fuse110V AC
    230V AC
    3IP20
    Gray7641K86500000000007641K76500007641K7570000Noninsulated7641K1600000
     
    400V AC/400V DC—6.3 amp per Circuit
    1222 to 128565 mm20 mmCeramic, GlassBlown Fuse24V AC
    24V DC
    1, 3IP20
    Gray7641K94300000000007641K3700007641K350000———0
    1222 to 128565 mm20 mmCeramic, GlassBlown Fuse110V AC
    230V AC
    1, 3IP20
    Gray7641K94200000000007641K3700007641K350000———0
     
    600V AC—6.3 amp per Circuit
    2224 to 12885.55 mm20 mmCeramic, GlassBlown Fuse110V AC
    230V AC
    1, 3IP20
    Gray7641K86300000000007641K75900007641K7570000Insulated7641K76400000
    2212
    885.55 mm20 mmCeramic, GlassBlown Fuse24V AC
    24V DC
    1, 3IP20
    Gray7641K86200000000007641K75900007641K7570000Insulated7641K76400000
     
    630V AC—6.3 amp per Circuit
    1222 to 128565 mm20 mmCeramic, Glass1, 3IP20
    Gray, Orange7641K55000000007641K3700007641K350000———0
     
    630V AC/630V DC—6.3 amp per Circuit
    2224 to 12885.55 mm20 mmCeramic, Glass1, 3IP20
    Gray7641K84900000000007641K75900007641K7570000Insulated7641K76400000
     
    800V AC/800V DC—10 amp per Circuit
    1222 to 101385.13AG1/4"GlassBlown Fuse24V AC
    24V DC
    1, 3IP20
    Black7641K94600000000007641K4900007641K350000———0
    1222 to 101385.13AG1/4"GlassBlown Fuse110V AC
    230V AC
    1, 3IP20
    Black7641K94500000000007641K4900007641K350000———0
     
    800V AC—16 amp per Circuit
    1222 to 101385.13AG1/4"Glass1, 3IP20
    Black7641K360000000007641K4900007641K350000———0
     
    800V AC—30 amp per Circuit
    1218 to 62290.713/32"1 1/2"Cartridge1, 3IP20
    Gray7641K9320000000000———07641K350000———0
     
    Markers

    Quick-Connect Modular DIN-Rail Mount Terminal Blocks

    Image of System. Front orientation. Contains Annotated. Terminal Blocks. Quick-Connect Modular DIN-Rail Mount Terminal Blocks.
    Pop wire in and out of these terminal blocks without adjusting a screw. Lift the clamp with a screwdriver or built-in lever, then release the clamp down onto the wire. Once clamped in place, the wire will stay put when vibrated, bent, or pulled.
    Mix and match these terminal blocks to get the exact number of circuits you need in a single setup. Add blocks for thermocouples, fuses, and grounding wire as needed. The blocks clip side by side onto DIN rail in control panels, creating tidy rows of circuits that you can identify and access on the spot.
    Fuse Terminal Blocks with Spring-Clamp Terminals
    Image of Product. Front orientation. Terminal Blocks. Quick-Connect Modular DIN-Rail Mount Terminal Blocks, Fuse Terminal Blocks with Spring-Clamp Terminals.
    Install a fuse in the built-in fuse holder so excess current doesn't damage your equipment. If the current exceeds the limit, the fuse will blow and cut power to connected components.
    Blown Fuse Indicator—A light goes on when the fuse blows, so you can spot an overloaded circuit without cutting power or touching equipment.
    Covers—Snap onto the exposed side of a terminal block to prevent accidental contact with a live wire.
    End Stops—Mount at the end of a group of terminal blocks so they don't slide when vibrated or bumped.
    Adjacent Jumpers—Metal poles create an electrical connection between adjacent terminal blocks, so you can connect multiple components with a single wire. Blocks must be the same width for the jumpers to fit.
    Terminal Blocks
    Covers
    End Stops
    Adjacent Jumpers
    For Fuse
    Each
    No. of
    Circuits
    No. of Terminals
    per Circuit
    For Wire
    Ga.
    Wd.,
    mm
    Ht.,
    mm
    Trade
    Size
    Overall
    Dia.
    Overall
    Lg., mm
    Type
    Circuit Status
    Indicator Type
    Color
    For DIN Rail
    Trade Size
    1-24
    25-Up
    Each
    Each
    Insulation
    Each
     
    24V AC/24V DC—30 amp per Circuit
    1224 to 10885AutomotiveBlown FuseGray39553T120000000000009553T9000009473T14400000Insulated9473T11800000
     
    110V AC/110V DC—10 amp per Circuit
    1228 to 128605 mm20Ceramic, GlassBlown FuseGray39553T1100000000009553T200009473T1440000Insulated9473T1150000
    1228 to 1210603AG1/4"GlassBlown FuseGray39553T1300000000009553T200009473T1440000Insulated9473T1150000
     
    600V AC/600V DC—10 amp per Circuit
    1228 to 128605 mm20Ceramic, GlassGray39553T100000000009553T200009473T1440000Insulated9473T1150000
    1228 to 1210603AG1/4"GlassGray39553T300000000009553T200009473T1440000Insulated9473T1150000
     
    600V AC/600V DC—30 amp per Circuit
    1224 to 10885AutomotiveGray39553T800000000009553T900009473T1440000Insulated9473T1180000
     
    Markers

    DIN-Rail Mount Fuse Blocks for UL Class J Fuses

    Image of Product. For 1 Fuse. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class J Fuses, For 1 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class J Fuses, For 2 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class J Fuses, For 3 Fuses.

    For 1 Fuse

    For 2 Fuses

    For 3 Fuses

    Covered terminals prevent contact with live electrical circuits.
    For Fuse
    For No.
    of Fuses
    UL
    Class
    Current,
    amp
    Type
    Voltage,
    V AC
    Wire
    Connection
    For DIN
    Rail Size, mm
    Features
    Wd.
    Ht.
    Dp.
    Certification
    Each
    For Fuse Manufacturer Equivalent: A4J, AJT, JKS, JLS, JTD, LPJ
    1J1 to 30Cartridge600Screw Terminal35Covered Terminals1.28"4.49"3.15"UL Listed, CSA Certified
    7721K15000000
    1J1 to 30Cartridge600Screw Terminal35Covered Terminals, Blown-Fuse Indicator1.28"4.49"3.15"UL Listed, CSA Certified
    7721K1600000
    1J31 to 60Cartridge600Screw Terminal35Covered Terminals1.57"4.8"3 1/2"UL Listed, CSA Certified
    7721K1700000
    1J31 to 60Cartridge600Screw Terminal35Covered Terminals, Blown-Fuse Indicator1.57"4.8"3 1/2"UL Listed, CSA Certified
    7721K1800000
    2J1 to 30Cartridge600Screw Terminal35Covered Terminals2.56"4.49"3.15"UL Listed, CSA Certified
    7721K2300000
    2J1 to 30Cartridge600Screw Terminal35Covered Terminals, Blown-Fuse Indicator2.56"4.49"3.15"UL Listed, CSA Certified
    7721K2400000
    2J31 to 60Cartridge600Screw Terminal35Covered Terminals3.14"4.8"3 1/2"UL Listed, CSA Certified
    7721K2900000
    2J31 to 60Cartridge600Screw Terminal35Covered Terminals, Blown-Fuse Indicator3.14"4.8"3 1/2"UL Listed, CSA Certified
    7721K31000000
    3J1 to 30Cartridge600Screw Terminal35Covered Terminals3.84"4.49"3.15"UL Listed, CSA Certified
    7721K25000000
    3J1 to 30Cartridge600Screw Terminal35Covered Terminals, Blown-Fuse Indicator3.84"4.49"3.15"UL Listed, CSA Certified
    7721K26000000
    3J31 to 60Cartridge600Screw Terminal35Covered Terminals4.71"4.8"3 1/2"UL Listed, CSA Certified
    7721K32000000
    3J31 to 60Cartridge600Screw Terminal35Covered Terminals, Blown-Fuse Indicator4.71"4.8"3 1/2"UL Listed, CSA Certified
    7721K33000000
     

    DIN-Rail/Surface-Mount Fuse Blocks

    Image of Product. For 1 Fuse. Front orientation. Fuse Blocks. DIN-Rail/Surface-Mount Fuse Blocks, For 1 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail/Surface-Mount Fuse Blocks, For 2 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail/Surface-Mount Fuse Blocks, For 3 Fuses.

    For 1 Fuse

    For 2 Fuses

    For 3 Fuses

    Fuse blocks have a universal hole pattern, so they can be mounted on either DIN-rail or directly onto surfaces.
    For Fuse
    For No.
    of Fuses
    UL
    Class
    Current,
    amp
    Type
    Voltage
    Wire Connection
    For DIN
    Rail Size, mm
    Certification
    Each
    For Fuse Manufacturer Equivalent: A2D-R, FLN-R, FRN-R, LLN-RK, LPN-RK, TR-R
    1RK1, RK51 to 30Cartridge250V AC/250V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K11000000
    1RK1, RK531 to 60Cartridge250V AC/250V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K1400000
    2RK1, RK51 to 30Cartridge250V AC/250V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K1200000
    2RK1, RK531 to 60Cartridge250V AC/250V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K1500000
    3RK1, RK51 to 30Cartridge250V AC/250V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K1300000
    3RK1, RK531 to 60Cartridge250V AC/250V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K1600000
     
    For Fuse Manufacturer Equivalent: A4J, AJT, JKS, JLS, JTD, LPJ-SP
    1J1 to 30Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K3100000
    1J31 to 60Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K3400000
    2J1 to 30Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K3200000
    2J31 to 60Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K3500000
    3J1 to 30Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K3300000
    3J31 to 60Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K3600000
     
    For Fuse Manufacturer Equivalent: A6K-R, FLS-R, FRS-R, IDSR, KLS-R, KTS-R, LLS-RK, LPS-RK, TRS-R
    1RK1, RK51 to 30Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K2100000
    1RK1, RK531 to 60Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K2400000
    2RK1, RK51 to 30Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K2200000
    2RK1, RK531 to 60Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K2500000
    3RK1, RK51 to 30Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K2300000
    3RK1, RK531 to 60Cartridge600V AC/600V DCBox-Lug Terminal35UL Listed, CSA Certified
    4294K2600000
     

    DIN-Rail Mount Fuse Blocks for Midget Fuses

    Image of Product. For 1 Fuse. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for Midget Fuses, For 1 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for Midget Fuses, For 2 Fuses.
    Image of Product. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for Midget Fuses, For 3 Fuses.

    For 1 Fuse

    For 2 Fuses

    For 3 Fuses

    Sized to fit non-UL Class Midget Fuses, these fuse blocks are suitable for switchboard panels, small motors, and transformers. The covered terminals prevent contact with live electrical circuits.
    For
    Fuse
    For No.
    of Fuses
    Current,
    amp
    Type
    Voltage
    Wire
    Connection
    For DIN
    Rail Size, mm
    Features
    Wd.
    Ht.
    Dp.
    Certification
    Each
    For Fuse Manufacturer Equivalent: ATM, ATQ, BAF, BLF, FLM, FLQ, FNM, FNQ, KLK, KTK, OTM, TRM
    11/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals0.7"3.1"2.3"UL Recognized Component, CSA Certified
    7722K21000000
    11/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals, Blown-Fuse Indicator0.7"3.1"2.3"UL Recognized Component, CSA Certified
    7722K2200000
    21/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals1.4"3.1"2.3"UL Recognized Component, CSA Certified
    7722K2300000
    21/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals, Blown-Fuse Indicator1.4"3.1"2.3"UL Recognized Component, CSA Certified
    7722K2400000
    31/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals2.1"3.1"2.3"UL Recognized Component, CSA Certified
    7722K2500000
    31/10 to 30Cartridge600V AC/600V DCScrew Terminal35Covered Terminals, Blown-Fuse Indicator2.1"3.1"2.3"UL Recognized Component, CSA Certified
    7722K26000000
     

    Space-Saving Modular DIN-Rail Mount Terminal Blocks

    Image of System. Front orientation. Contains Annotated. Terminal Blocks. Space-Saving Modular DIN-Rail Mount Terminal Blocks.
    These handle the same voltage and power as our other modular blocks while taking up about half the vertical space. Snap them onto DIN 2 rail (also known as mini rail), which is lower in height than DIN 3 rail.
    The screw-clamp or spring-clamp terminals flatten your wire so it stays put when vibrated or pulled. For an even stronger and more conductive connection, crimp a terminal or wire ferrule onto the end of the wire.
    Mix and match blocks to get the exact number of circuits you need in a single setup. Add terminal blocks for fuses and grounding wire as needed. The blocks clip side by side onto DIN rail in control panels, creating tidy rows of circuits that you can identify and access on the spot.
    Fuse Terminal Blocks with Screw-Clamp Terminals
    Image of Product. Front orientation. Terminal Blocks. Space-Saving Modular DIN-Rail Mount Terminal Blocks, Fuse Terminal Blocks with Screw-Clamp Terminals.
    Install a fuse in the built-in fuse holder so excess current doesn't damage your equipment. If the current exceeds the limit, the fuse will blow and cut power to connected components.
    A screw presses the clamp onto the wire for a secure hold.
    Covers—Snap onto the exposed side of a terminal block to prevent accidental contact with a live wire.
    End Stops—Mount at the end of a group of terminal blocks so they don't slide when vibrated or bumped.
    Terminal Blocks
    Covers
    End Stops
    For Fuse
    Each
    No. of
    Circuits
    No. of Terminals
    per Circuit
    For Wire
    Ga.
    Wd.,
    mm
    Ht.,
    mm
    Overall
    Dia., mm
    Overall
    Lg., mm
    Type
    Color
    For DIN Rail
    Trade Size
    Enclosure
    Rating
    1-24
    25-Up
    Each
    Each
     
    630V AC—6.3 amp per Circuit
    1218 to 12859.5520Ceramic, GlassGray2IP20
    7641K5800000000007641K37000007641K6900000
     
    Markers

    DIN-Rail Mount Fuse Blocks for UL Class CF Fuses

    Image of ProductInUse. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for UL Class CF Fuses.
    These fuse blocks have covered terminals to prevent accidental contact with live electrical circuits. Gang them together to create double- and triple-pole configurations.
    For Fuse
    For No.
    of Fuses
    UL
    Class
    Current,
    amp
    Type
    Protection
    Type
    Voltage
    Wire
    Connection
    For DIN
    Rail Size, mm
    Features
    Wd.
    Ht.
    Dp.
    Certification
    Specs. Met
    Each
    1CF1 to 30Branch CircuitTouch Safe600V AC/300V DCScrew Terminal35Covered Terminals0.76"2.3"1.36"UL Listed, CSA Certified
    EN 63000, IEC 630008078K31000000
    1CF35 to 60Branch CircuitTouch Safe600V AC/300V DCScrew Terminal35Covered Terminals1.03"2.6"1.6"UL Listed, CSA Certified
    EN 63000, IEC 630008078K3200000
    1CF70 to 100Branch CircuitTouch Safe600V AC/300V DCScrew Terminal35Covered Terminals1.05"2.91"2.01"UL Listed, CSA Certified
    EN 63000, IEC 630008078K4100000
     

    DIN-Rail Mount Fuse Blocks for 1,000V DC Fast-Acting Fuses

    Image of ProductInUse. Front orientation. Fuse Blocks. DIN-Rail Mount Fuse Blocks for 1,000V DC Fast-Acting Fuses.
    Designed for the solar industry, these fuse blocks can handle the requirements of high-voltage DC applications. The covered terminals prevent contact with live electrical circuits.
    For Fuse
    For No.
    of Fuses
    Current,
    amp
    Overall
    Dia.
    Overall
    Lg.
    Type
    Voltage,
    V DC
    Wire
    Connection
    For DIN
    Rail Size, mm
    Features
    Certification
    Specs. Met
    Each
    For Fuse Manufacturer Equivalent: DCT, PV
    11 to 1513/32"1 1/2"Cartridge1,000Screw Terminal35Covered TerminalsUL Recognized Component
    EN 63000, IEC 630004504K7000000
    11 to 1513/32"1 1/2"Cartridge1,000Screw Terminal35Covered Terminals, Blown-Fuse IndicatorUL Recognized Component
    EN 63000, IEC 630004504K900000
     
    back to top