Top Material Top Material |
---|
|
Frame Finish Frame Finish |
---|
|
Overall Capacity Overall Capacity |
---|
|
|
Top Capacity Top Capacity |
---|
|
|
Pull metal particles from grinding, cutting, and finishing workpieces into these tables to avoid breathing them. These tables also help keep combustible particles from creating sparks in your work area. Blowers pull dust and powder into the tables through holes in the surface, removing them from the air. Once inside, the particles are captured with filters or water, and clean air is released back into your space.
Vertical shields on the back and sides of these tables help protect you from flying debris. Some shields are removable, so you can make space for large workpieces. The removable trays at the bottom of these tables catch large chips and scraps, making them easy to clean up.
Dry-Capture Tables
These tables pull particles directly into fireproof filters. Made from aluminum, the filters won't spark from metal particles hitting them. Dry-capture tables are best for grinding and cutting jobs that create large particles. They are not designed for capturing fine powders, such as dust from sanding aluminum, titanium, and steel. For large-scale projects, use 1-hp tables. They generate stronger suction than ½-hp tables to capture a large amount of particles.
Wet-Capture Tables
Instead of an aluminum filter, these tables pull particles out of the air and into a water tank. The water traps particles, forming a sludge that settles to the bottom of the tank. Unlike dry-capture tables, wet-capture tables catch the fine dust and powder created by sanding metal. They exhaust clean air either down toward the floor or up and out of your work area. For especially dusty jobs, exhausting the air out of your building helps protect you from breathing in remaining traces of metal powder.
Fill the internal tank by attaching your water source to the inlet. Water level sensors inside the tank make sure you have the right amount of water for filtering. These sensors work with a solenoid on/off valve to automatically start the flow of water when the tank is low, and stop it when the tank is full. Mist traps keep moisture from escaping into the air.
Connect air-powered tools, such as sanders and grinders, directly to these tables via the air inlet. They have an interlocking pneumatic valve that keeps air from running to your tool until the table's blower is fully up to speed. This keeps you from starting up a tool before the table is ready to filter. Roll these tables where they're needed, and lock the casters in place while you're working.
Both the blower and table surface are made from aluminum, which won't spark if metal particles strike it. The motors in these tables meet NEC Class II, Divisions 1 and 2, Groups E, F, and G requirements, which means they will not explode from combustible dust.
For technical drawings and 3-D models, click on a part number.
Tables | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Opening | Replacement Filters | ||||||||||||||
Airflow, cfm | hp | Current, A | Volume, dB | Removes Particle Size Down To, microns | Ht. | Wd. | Dp. | Lg. | Wd. | O'all Cap., lbs. | Features | Includes | Each | Each | ||
Powder-Coated Steel Frame with Stainless Steel Top | ||||||||||||||||
120V AC, 60Hz—Hardwire | ||||||||||||||||
1,790 | 1/2 | 6 | 78 | 250 | 34 3/4" | 65 3/4" | 24 3/4" | 2" | 7/8" | 440 | Removable Side Shields, Removable Tray | Four 250 Micron Fireproof Filters | 00000000 | 000000000 | 00000000 | 0000000 |
240V AC, 60Hz—Hardwire | ||||||||||||||||
1,950 | 1 | 8.5 | 82 | 250 | 34 3/4" | 87 1/2" | 29 1/2" | 2" | 7/8" | 660 | Removable Side Shields, Removable Tray | Four 250 Micron Fireproof Filters | 00000000 | 00000000 | 00000000 | 000000 |
Overall | Opening | Air Inlet and Outlet (NPT Threads) | Water Inlet (NPT Threads) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | hp | Current, A | Volume, dB | Exhaust Direction | Ht. | Wd. | Dp. | Lg. | Wd. | Pipe Size | Gender | Pipe Size | Gender | Tank Cap., gal. | O'all Cap., lbs. | Environment | Features | Includes | Each | |
Powder-Coated Steel Frame with Aluminum Top | ||||||||||||||||||||
240V AC, 60Hz—NEMA L15-20 Plug | ||||||||||||||||||||
1,800 | 3 | 6 | 85 | Down | 59" | 71" | 53" | 1 1/2" | 1/4" | 1/2 | Female | 1/4 | Female | 42 | 2,000 | Hazardous Location | Interlocking Pneumatic Valve, Mist Traps, Removable Side and Back Shields, Removable Tray, Solenoid On/Off Valve | 3/4" Female Garden Hose Swivel Adapter | 00000000 | 0000000000 |
1,800 | 3 | 6 | 85 | Up | 59" | 71" | 53" | 1 1/2" | 1/4" | 1/2 | Female | 1/4 | Female | 42 | 2,000 | Hazardous Location | Interlocking Pneumatic Valve, Mist Traps, Removable Side and Back Shields, Removable Tray, Solenoid On/Off Valve | 3/4" Female Garden Hose Swivel Adapter | 00000000 | 000000000 |
460V AC, 60Hz—NEMA L16-20 Plug | ||||||||||||||||||||
1,800 | 3 | 3.3 | 85 | Down | 59" | 71" | 53" | 1 1/2" | 1/4" | 1/2 | Female | 1/4 | Female | 42 | 2,000 | Hazardous Location | Interlocking Pneumatic Valve, Mist Traps, Removable Side and Back Shields, Removable Tray, Solenoid On/Off Valve | 3/4" Female Garden Hose Swivel Adapter | 00000000 | 000000000 |
1,800 | 3 | 3.3 | 85 | Up | 59" | 71" | 53" | 1 1/2" | 1/4" | 1/2 | Female | 1/4 | Female | 42 | 2,000 | Hazardous Location | Interlocking Pneumatic Valve, Mist Traps, Removable Side and Back Shields, Removable Tray, Solenoid On/Off Valve | 3/4" Female Garden Hose Swivel Adapter | 00000000 | 000000000 |
Keep sawdust and other particles out of the air while drilling, sanding, and finishing wood products. Air blowers pull particles into the table through holes in the surface, making sure you don't breathe them. Inside the table, filters remove the particles, and exhaust vents release clean air back into your shop.
These tables should only be used with wood, plastic composites, and other non-combustible materials. Do not use them to filter materials that may create sparks, such as metallic dust. They are not designed to filter liquids, exhaust fumes, or smoke.
When choosing a table, consider the size of the particles you need to filter.
For cutting, routing, and other jobs that create large particles, use 5-micron tables. Rubber grommets built into the surface help keep your workpiece from slipping. The removable tray catches large chips and scraps that fall to the bottom of the table, making them easy to clean up. These tables have side shields to protect you from flying debris, which fold down if you need to make space for large workpieces. When doing precision work, use the removable plugs to block holes in the tabletop so small parts don't fall through. 65" wide tables have a blower on each side for even suction across the table surface.
3-micron tables are good for jobs that create fine dust and powder, such as sanding wood to an extra-fine finish. They have a stronger motor and higher airflow than 5-micron tables, which creates stronger suction. The table surface has an antislip coating that helps keep your workpiece in place. Roll these tables where you need them, then lock the casters in place while you work. Use the storage compartment to keep tools and other accessories handy.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Horsepower, hp | Current, A | Volume, dB | Ht. | Wd. | Dp. | Opening Dia. | O'all Cap., lbs. | Features | Includes | Each | |
Powder-Coated Steel Frame and Top | ||||||||||||
120V AC, 60Hz—Hardwire | ||||||||||||
1,790 | 1/2 | 6 | 70 | 33 1/2" | 41" | 23 1/2" | 7/8" | 660 | Antislip Rubber Grommets, Removable Side Shields, Removable Tray | Removable Plugs, Two 5 Micron Filters | 00000000 | 000000000 |
1,790 | 1/2 | 6 | 78 | 33 1/2" | 65" | 25 1/2" | 7/8" | 660 | Antislip Rubber Grommets, Removable Side Shields, Removable Tray | Removable Plugs, Two 5 Micron Filters | 00000000 | 00000000 |
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Horsepower, hp | Current, A | Volume, dB | Ht. | Wd. | Dp. | Opening Dia. | O'all Cap., lbs. | Features | Includes | Each | |
Painted Plywood Frame with Oak Top | ||||||||||||
120V AC, 60Hz—3-Prong Plug | ||||||||||||
3,000 | 1 | 13 | 72 | 36" | 41" | 33" | 3/8" | 250 | Antislip Surface, Dust-Tight Electrical Outlets, Storage Compartment | Pre-Filter Blanket, Two MERV 8 Pleated Paper Filters | 00000000 | 000000000 |
3,000 | 1 | 13 | 72 | 36" | 60" | 33" | 3/8" | 250 | Antislip Surface, Dust-Tight Electrical Outlets, Storage Compartment | Pre-Filter Blanket, Two MERV 8 Pleated Paper Filters | 00000000 | 00000000 |