McMaster-Carr logo
    Filter by
    Mounting Location
    Electrical Phase
    Drive Type
    Blade Material
    Number of Speeds
    Power Source
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    168 Products

    Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 1.
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 2.
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.

    Style 1

    Style 2

    Style 3

    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 4.
    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 4

    Style 5

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 1.
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 2.
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 4.

    Style 1

    Style 2

    Style 3

    Style 4

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient Temp.,
    ° F
    Frame
    Material
    Blade
    Material
    Certification
    Each
    Each
    18"520Not RatedDirect3,12511/1012 1/4"12 1/4"3 1/8"8149SteelSteelUL Recognized Component
    0000000000000———0
    110"1,000Not RatedDirect2,65011/414 5/8"14 5/8"3 1/4"12Not RatedSteelSteelUL Recognized Component
    000000000000———0
    112"1,500Not RatedDirect2,85011/417"17"3 3/4"14Not RatedSteelSteelUL Recognized Component
    000000000000———0
    114"1,800Not RatedDirect1,52511/419"19"4 1/8"1877SteelSteelUL Recognized Component
    000000000000———0
    217"3,225Not RatedDirect1,62013/821 7/16"6 1/2"19Not RatedSteelSteelUL Recognized Component
    000000000000———0
    310"680Not RatedDirect1,56031/2012 1/2"12 1/2"9 5/8"11104SteelAluminum
    ETL Listed
    0000000000000———0
    312"825Not RatedDirect1,56031/1214 1/2"14 1/2"11"14100SteelAluminum
    UL Recognized Component
    0000000000000———0
    316"2,100Not RatedDirect1,66031/819"19"12"21100SteelAluminum
    UL Recognized Component
    0000000000000———0
    318"2,300Not RatedDirect1,66031/821"21"10 3/4"26104SteelAluminum
    ETL Listed
    0000000000000———0
    320"2,925Not RatedDirect1,14021/423"23"12"35100SteelAluminum
    UL Recognized Component
    0000000000000———0
    324"4,80056 dB @ 5 ft.Direct85011/230"30"15 1/2"45104SteelAluminum
    000000000000000000000000000
    430"7,30061 dB @ 5 ft.Direct82511/236"36"13 3/4"75104SteelSteel0000000000000000000000000000
    436"8,60065 dB @ 5 ft.Direct82511/242"42"12 1/4"95104SteelSteel0000000000000000000000000000
    120V AC, Single Phase (Hardwire)—Totally Enclosed Air-Over (TEAO) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.

    Style 3

    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Each
    38"40034 dBA @ 15 ft.Direct1,55011/3013"13"6 5/8"15104SteelAluminum
    00000000000000
    208 to 230V AC/460V AC, Three Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 4.

    Style 4

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Each
    Each
    430"7,30061 dB @ 5 ft.Direct82511/236"36"13 3/4"74104SteelSteel000000000000000000000000000000
    436"8,60064 dB @ 5 ft.Direct1,14013/442"42"12 1/4"95104SteelSteel0000000000000000000000000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 5

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Each
    Each
    518"3,90066 dB @ 5 ft.Direct1,75011/224"24"10"42104SteelSteel000000000000000000000000000
    524"4,60056 dB @ 5 ft.Direct85011/230"30"15 1/2"70104SteelAluminum
    0000000000000000000000000000
    524"6,80072 dB @ 5 ft.Direct1,7501130"30"12 1/4"78104SteelSteel000000000000000000000000000
    530"14,40080 dB @ 5 ft.Direct1,7501336"36"14 1/4"148104SteelSteel0000000000000000000000000000
    536"20,30083 dB @ 5 ft.Direct1,7501542"42"15 3/4"225104SteelSteel0000000000000000000000000000
    542"26,60080 dB @ 5 ft.Direct1,1501548"48"20"295104SteelSteel0000000000000000000000000000
    548"37,10082 dB @ 5 ft.Direct1,15017 1/254"54"22 1/2"470104SteelSteel0000000000000000000000000000

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Direct-Drive Wall-Mount Exhaust Fans .
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Exhaust Fan Collars—Use a collar (sold separately) to connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Certification
    Each
    Each
    8"40053 dBA @ 5 ft.Direct1,55011/2512 1/8"12 1/8"5 3/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    0000000000000000000000000000
    10"80057 dBA @ 5 ft.Direct1,55011/2016 1/8"16 1/8"8 3/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    12"1,50060 dBA @ 5 ft.Direct1,55011/816 1/8"16 1/8"8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    14"2,40068 dBA @ 5 ft.Direct1,55011/320 1/8"20 1/8"9 7/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    16"3,40069 dBA @ 5 ft.Direct1,55013/420 1/8"20 1/8"11 1/4"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    18"4,20069 dBA @ 5 ft.Direct1,55013/424 1/8"24 1/8"11 3/4"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    20"4,10064 dBA @ 5 ft.Direct1,07511/224 1/8"24 1/8"10 5/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    24"6,60067 dBA @ 5 ft.Direct1,07513/430 1/8"30 1/8"11 1/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. 120V AC. Direct-Drive Wall-Mount Exhaust Fans .
    Louvers—Fans with louvers create a weather-tight seal when they're turned off. The louvers open automatically on startup and spring closed when not in use.
    Hoods—Hoods (sold separately) help extend the life of your exhaust fan by protecting it from harsh weather, such as severe wind, and debris.
    Exhaust Fans
    Hoods
    For
    Opening
    Overall
    Mounting
    Hole
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Dia.
    Location
    No.
    of
    Includes
    Each
    Each
    12"900Not RatedDirect1,72511/1013 3/4"13 3/4"16 1/8"16 1/8"15 3/16"100Galvanized SteelAluminum
    3/16"Frame4Louvers0000000000000000000000000000
    15"2,300Not RatedDirect1,72511/318"18"20"20"17 1/4"100Galvanized SteelAluminum
    3/16"Frame4Louvers00000000000000000000000000
    20"3,100Not RatedDirect1,72511/322"22"23 1/2"23 1/2"18 3/4"100Galvanized SteelAluminum
    3/16"Frame4Louvers000000000000000000000000000
    24"4,800Not RatedDirect1,72511/225 1/4"25 1/4"28 1/4"28 1/4"20 3/4"100Galvanized SteelAluminum
    3/16"Frame4Louvers000000000000000000000000000

    Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

    These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    10"680Not RatedDirect1,56031/1210 1/2"10 1/2"13"13"8 1/8"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000
    12"825Not RatedDirect1,56031/1212 1/2"12 1/2"15"15"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    14"1,520Not RatedDirect1,66031/814 1/2"14 1/2"17"17"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    18"2,300Not RatedDirect1,66031/818 1/2"18 1/2"21"21"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    20"2,925Not RatedDirect1,14021/420 1/2"20 1/2"23"23"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    30"3,950Not RatedDirect1,14021/430 1/2"30 1/2"33"33"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    120V AC, Single Phase—3-Blade Plug
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    10"680Not RatedDirect1,56031/1210 1/2"10 1/2"13"13"8 1/8"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000
    12"825Not RatedDirect1,56031/1212 1/2"12 1/2"15"15"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    14"1,520Not RatedDirect1,66031/814 1/2"14 1/2"17"17"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    18"2,300Not RatedDirect1,66031/818 1/2"18 1/2"21"21"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    20"2,925Not RatedDirect1,14021/420 1/2"20 1/2"23"23"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    30"3,950Not RatedDirect1,14021/430 1/2"30 1/2"33"33"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    20"2,820Not RatedDirect1,72011/320 1/2"20 1/2"23"23"12 1/2"100SteelAluminum
    No1/4"UL Recognized Component
    000000000000000
    24"3,950Not RatedDirect1,72011/224 1/2"24 1/2"28"28"17"100SteelAluminum
    No1/4"UL Recognized Component
    00000000000000
    30"5,745Not RatedDirect85011/230 1/2"30 1/2"33"33"15 1/4"100SteelAluminum
    No1/4"UL Recognized Component
    00000000000000

    Equipment-Cooling Fan Guards

    Image of Product. Style A. Front orientation. Fan Guards. Equipment-Cooling Fan Guards, For Round and Square Fans, Style A.
    Image of Product. Style B. Front orientation. Fan Guards. Equipment-Cooling Fan Guards, For Round and Square Fans, Style B.
    Image of Product. Style D. Front orientation. Fan Guards. Equipment-Cooling Fan Guards, For Round and Oblong Fans, Style D.

    Style A

    Style B

    Style D

    Protect fingers, cables, and debris from coming into contact with moving fan blades.
    For Round and Square Fans
    Image of Product. Style A. Front orientation. Fan Guards. Equipment-Cooling Fan Guards, For Round and Square Fans, Style A.
    Image of Product. Style B. Front orientation. Fan Guards. Equipment-Cooling Fan Guards, For Round and Square Fans, Style B.

    Style A

    Style B

    For
    Fan
    Nickel-Plated
    Steel
    Black
    Electrocoated Steel
    Gray
    Powder-Coated Steel
    Style
    Ht.
    Wd.
    Dia.
    Each
    Each
    Each
    A0.98" (25 mm)0.98" (25 mm)0.98" (25 mm)0000000000000———0———0
    B0.98" (25 mm)0.98" (25 mm)0.98" (25 mm)———000000000000000———0
    B1.18" (30 mm)1.18" (30 mm)1.18" (30 mm)00000000000000000000000000———0
    B1.37" (35 mm)1.37" (35 mm)1.37" (35 mm)0000000000000———0———0
    B1.41" (36 mm)1.41" (36 mm)1.41" (36 mm)0000000000000———0———0
    B1.57" (40 mm)1.57" (40 mm)1.57" (40 mm)0000000000000000000000000———0
    B1.97" (50 mm)1.97" (50 mm)1.97" (50 mm)0000000000000000000000000———0
    B2.36" (60 mm)2.36" (60 mm)2.36" (60 mm)0000000000000000000000000———0
    B2.75" (70 mm)2.75" (70 mm)2.75" (70 mm)0000000000000———0———0
    B3.15" (80 mm)3.15" (80 mm)3.15" (80 mm)0000000000000000000000000———0
    B3.62" (92 mm)3.62" (92 mm)3.62" (92 mm)0000000000000000000000000———0
    B4.69", 4.72" (119 mm, 120 mm)4.69", 4.72" (119 mm, 120 mm)4.69", 4.72" (119 mm, 120 mm)0000000000000000000000000———0
    B4.72" (120 mm)4.72" (120 mm)4.72" (120 mm)0000000000000———0———0
    B5", 5.31" (127 mm, 135 mm)5", 5.31" (127 mm, 135 mm)5", 5.31" (127 mm, 135 mm)000000000000———0———0
    B5.31" (127 mm)5.31" (127 mm)5.31" (127 mm)———00000000000000———0
    B6.89" (175 mm)6.89" (175 mm)6.89" (175 mm)000000000000———0———0
    B7.87" (200 mm)7.87" (200 mm)7.87" (200 mm)0000000000000———0———0
    B8.86" (225 mm)8.86" (225 mm)8.86" (225 mm)———0———000000000000000
    B10" (254 mm)10" (254 mm)10" (254 mm)0000000000000000000000000———0
    B11.02" (280 mm)11.02" (280 mm)11.02" (280 mm)———0———00000000000000
     
    For Round and Oblong Fans
    Image of Product. Style D. Front orientation. Fan Guards. Equipment-Cooling Fan Guards, For Round and Oblong Fans, Style D.

    Style D

    For
    Fan
    Nickel-Plated
    Steel
    Black
    Electrocoated Steel
    Style
    Ht.
    Wd.
    Dia.
    Each
    Each
    D5.91" (150 mm)6.77" (172 mm)5.91", 6.77" (150 mm, 172 mm)000000000000000000000000000
     

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    10"87056 dBA @ 5 ft.Direct1,55011/2017 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    12"1,50060 dBA @ 5 ft.Direct1,55011/817 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    16"2,50061 dBA @ 5 ft.Direct1,30011/221 1/4"21 1/4"23 1/2"23 1/2"25 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    18"3,80065 dBA @ 5 ft.Direct1,30013/425 1/4"25 1/4"27 1/2"27 1/2"26 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    24"6,60067 dBA @ 5 ft.Direct1,07513/431 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    Replacement Fan Motors
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    24"5,20069 dBA @ 5 ft.Direct1,12511/231 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    Replacement Fan Motors
    230/460V AC, Three Phase—Hardwire
    Cannot Be Sold to California—Fans that cannot be sold to California are restricted by local energy efficiency requirements.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Cannot Be
    Sold To
    Each
    30"8,40074 dBA @ 5 ft.Direct1,1251137 1/4"37 1/4"39 1/2"39 1/2"27 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California00000000000000000
    36"12,30074 dBA @ 5 ft.Direct85011 1/243 1/4"43 1/4"45 1/2"45 1/2"31 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California0000000000000000

    Belt-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans with Louvers .
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"19"152104SteelSteelSteelNo3/16"0000000000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"19"121104SteelSteelSteelNo3/16"000000000000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"19"270104SteelSteelSteelNo3/16"000000000000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"19"266104SteelSteelSteelNo3/16"000000000000000
    Replacements for Exhaust Fans
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"25"153104SteelSteelSteelNo3/16"0000000000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"25"225104SteelSteelSteelNo3/16"000000000000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"25"250104SteelSteelSteelNo3/16"000000000000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"25"324104SteelSteelSteelNo3/16"000000000000000
    Replacements for Exhaust Fans

    Belt-Drive Wall-Mount Exhaust Fans

    Use these fans to draw stagnant and humid air out of a room or area. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Back orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans .
    Image of Product. Front orientation. Exhaust Fan Collars. Belt-Drive Wall-Mount Exhaust Fans .

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    30"8,20056 dB @ 5 ft.Belt60011/236"36"18 3/8"SteelSteel0000000000000000000000000000
    36"10,60056 dB @ 5 ft.Belt42511/242"42"18 5/8"SteelSteel0000000000000000000000000000
    48"18,50061 dB @ 5 ft.Belt4001154"54"24 3/4"SteelSteel0000000000000000000000000000
    Replacements for Exhaust Fans
    230/460V AC, Three Phase—Hardwire
    Image of Product. Back orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans .
    Image of Product. Front orientation. Exhaust Fan Collars. Belt-Drive Wall-Mount Exhaust Fans .

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    30"8,20056 dB @ 5 ft.Belt60011/236"36"18 3/8"SteelSteel0000000000000000000000000000
    36"10,60056 dB @ 5 ft.Belt42511/242"42"18 5/8"SteelSteel00000000000000000000000000
    48"18,50056 dB @ 5 ft.Belt4001154"54"24 3/4"SteelSteel0000000000000000000000000000
    Replacements for Exhaust Fans

    Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.
    Image of Product. Front orientation. Exhaust Fan Collars. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    36"14,20068 dB @ 5 ft.Belt80011 1/242"42"19 1/8"SteelSteel000000000000000000000000000000
    48"26,80072 dB @ 5 ft.Belt6001354"54"24 7/8"SteelSteel0000000000000000000000000000
    54"37,60070 dB @ 5 ft.Belt5251560"60"23 1/2"SteelSteel0000000000000000000000000000
    60"50,00079 dB @ 5 ft.Belt50017 1/266"66"23 1/2"SteelSteel0000000000000000000000000000

    Panel Fans

    Image of ProductInUse. Shown Mounted with Chains (Not Included). Front orientation. Fans. Panel Fans.

    Shown Mounted with

    Chains (Not Included)

    Mount these fans to a wide range of surfaces, such as posts, columns, and ceilings. They’re direct-drive fans, so they have fewer moving parts than belt-drive fans and require less maintenance. To suspend them, use the mounting chain kit (sold separately). Use mounting brackets (sold separately) to mount them to posts and columns.
    Fans with Totally Enclosed Motor Enclosure
    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Drive
    Type
    Frame Material
    Enclosure
    Rating
    Each
    190V AC to 208V AC/208V AC to 240V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    55"Plastic37,500 ft³/minNot Rated60012 15/1610.9 amp to 11.7 amp
    10.1 amp to 11.7 amp
    59"59"17 3/4"DirectGalvanized SteelIP65
    0000000000000000
    60"Plastic40,300 ft³/minNot Rated60012 15/1610.9 amp to 11.7 amp
    10.1 amp to 11.7 amp
    66"66"17 3/4"DirectGalvanized SteelIP65
    000000000000000
     
    208V AC to 240V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    50"Plastic30,800 ft³/minNot Rated60012 15/169.9 amp to 11.3 amp54"54"17 3/4"DirectGalvanized SteelIP65
    000000000000000
    55"Plastic37,400 ft³/minNot Rated60012 15/169.9 amp to 11.3 amp59"59"17 3/4"DirectGalvanized SteelIP65
    000000000000000
    60"Plastic40,800 ft³/minNot Rated60012 15/169.9 amp to 11.3 amp66"66"17 3/4"DirectGalvanized SteelIP65
    000000000000000
     
    380V AC to 460V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    50"Plastic29,600 ft³/minNot Rated60012 15/165.2 amp to 6.2 amp54"54"17 3/4"DirectGalvanized SteelIP65
    000000000000000
     
    Accessories for Fans
    back to top